UKNC: Residential (HQM) / HQM ONE / B My Home / 4 Comfort /

4.4 Sound Insulation

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Compliant test body – alternative compliance route using a Suitably Qualified Acoustician - KBCN1412

Where acoustic testing and measurement has not been performed by an organisation or individual that meets the definition of a compliant test body, compliance with this requirement can still be demonstrated where a Suitably Qualified Acoustician has reviewed the relevant test report(s). The test report must: a) Be countersigned or authorised by a Suitably Qualified Acoustician b) Include a clear statement that the acoustic testing and measurements have been carried out in accordance with the BREEAM or HQM testing requirements AND c) Include evidence that the verifier meets the definition for a Suitably Qualified Acoustician within the relevant BREEAM or HQM technical manual
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1

Robust Details – 01 Sound insulation between homes - KBCN1517

Due to HQM credit entitlements being unavailable for Robust Details wall and floor types, this route can no longer be used to demonstrate compliance with crit. 1

Sound Insulation between rooms - KBCN1114

This guidance is superseded. Please refer to KBCN1303
30-Oct-2025 - Superseded

Sound Insulation testing for Cupboards - KBCN1299

A cupboard (even built in) does not constitute a room and does not need to be assessed for the 'Sound insulation levels for internal walls and floors' credits as it is not permanent (part of the home's fabric) and also non-habitable.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
 

Sound testing between rooms - KBCN1303

Only lab tests carried out in accordance with Part E of the building regulations are accepted as evidence to show compliance with the requirements sound insulation between rooms ( 02 Sound insulation levels for internal walls and floors - HQM ONE). In-situ testing and software calculations are not acceptable ways of  showing compliance.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
 
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.