Access to HQM Logos, Marks and Badges - KBCN0995

All licensed HQM assessors should have access to the HQM ‘Logos, Marks and Badges Folder’ via BREEAM Projects

Design Stage evidence requirements when a contractor has not been appointed - KBCN1231

Where a contractor has not been appointed at the time of the design stage assessment, a contractually binding document, such as the Employers Requirements, may be used as evidence to demonstrate that the criteria will be met. Ultimately, the assessor should satisfy themselves that the evidence provided at design stage ensures that the criteria will be met later on in the project.

GN43 Home Quality Mark: Energy and Cost - KBCN1438

The purpose of this guidance note is to provide a background to the calculation methodologies underpinning the awarding of credits in the ‘Energy and Cost’ issue in the Home Quality Mark (HQM) ONE. See full Guidance Note (licensed assessors only) See all Guidance Notes (licensed assessors only)

GN44 Home Quality Mark Temperature Guidance - KBCN1439

This guidance note provides background to the calculation methodology that underpins the ‘HQM high temperature reporting tool’ and the ‘Temperature’ assessment issue in the Home Quality Mark technical manual (scheme versions: HQM ONE and Beta). See full Guidance Note (licensed assessors only) See all Guidance Notes (licensed assessors only)

Indicator backstops - KBCN1443

The indicator backstops set minimum performance levels for each of the three indicators (My costs, My wellbeing and My footprint), where a set number of credits must be achieved in key issues that are relevant to that indicator

Indicator backstops and HQM star rating - KBCN1442

The indicator backstops are independent from the HQM level/star rating. Therefore any particular indicator backstop level does not have to be achieved to achieve a particular star rating. There are a number of minimum requirements within key issues which apply for all star ratings . If these minimum requirements are not achieved, a HQM certificate cannot be issued.

Principal contractor or subcontractor no longer operational - KBCN0590

In situations where the principal contractor or other company involved in the project is no longer operational where, for example, the company has gone into administration, the assessor may be unable to obtain all the evidence to meet the requirements of BREEAM or HQM. For some BREEAM Issues, it may not be possible to demonstrate compliance retrospectively, and in such cases, the relevant credits must be withheld. However, in this situation, a lack of complete evidence will not, in itself, prevent the project from achieving a BREEAM rating and, where relevant, a prerequisite or minimum standard can be waived. For example:

UK NC V6 Man 03 Prerequisite - Legally harvested and traded timber or INC V6 Wst 03a – 1 credit to achieve an Excellent Rating

This is based on the project team demonstrating appropriate efforts to obtain the evidence from the company in administration and providing the following:
28 Oct 2024 - Title and general approach updated. Applied to HQM One/V6 and NC V6.

Scheme classification for residential projects (UK) - KBCN1225

Choosing the right scheme for developments is the starting point to ensure successful outcomes and value, in terms of quality and sustainability to building owners and for occupants of the building. In light of the release of Home Quality Mark (HQM) ONE we have reviewed the existing guidance around scheme classifications of new build residential buildings and have removed ‘GN03 – Scheme Classification – Domestic buildings’ from BREEAM Projects. When GN03 was written, the Code for Sustainable Homes (CSH) did not fully consider communal areas within residential blocks as part of the assessment. CSH was also not applicable in Scotland. GN03 was developed to clarify the differences between BREEAM Multi-Residential, CSH and EcoHomes, and when each scheme should be applied. There is now a clearer distinction between BREEAM Multi-residential and HQM and when these should be used. Ultimately, the determining factor for a scheme classification is now focused on the intent of the building and who is going to be the end user (as opposed to previous guidance which considered aspects such as percentage of communal areas, etc.). Broadly, if the building’s main purpose is for long term homes then Home Quality Mark is the correct scheme to use. Please use the following as guidance to identify the most appropriate scheme: UKNCR / Home Quality Mark (HQM) HQM has been designed with the occupant in mind. It assesses homes individually, but can also account for common areas associated with blocks of self-contained homes. HQM outputs (rating and indicators e.g. ‘my cost’, ‘my wellbeing’ and ‘my footprint’) are specifically aimed at those living in the home and are designed to better inform the occupant about the benefits of the home that they are purchasing or renting. An HQM project will meet one or more of the following criteria: Be designed to meet the function of a long-term self-contained home even though there may be some provision of communal facilities which can be used on a voluntary basis Be classified under Building regulations Part L1a (i.e. required to complete SAP assessments, although there may be some linked SBEM assessed spaces associated with the project) As such, HQM projects could be homes for sale, social housing or homes for rent (PRS and Built to Rent). They may also include some student and retirement/sheltered accommodation where the units are comparable to a normal self-contained flat/home. BREEAM Multi-residential For the purposes of BREEAM Multi-residential assessments, the term ‘multi-residential’ is used in the context of buildings that contain rooms for residential purposes alongside communal facilities for catering, leisure, care etc. These residential rooms would normally not have the full, self-contained functions of a home. This scheme usually covers more specialist residential care homes, student halls of residence, and other more communal accommodation. The scheme can cater for a small number of self-contained dwellings where these form part of a larger multi-residential development (e.g. on-site warden homes etc.). Under this scheme, the project is assessed on a whole building basis and as such does not seek to reflect the performance of individual residential units/rooms. A BREEAM Multi-residential project will meet one or more of the following criteria: Be provided for transient /non-permanent occupants Provide suitable accommodation for occupants requiring support from carers, wardens or similar Include shared living spaces Be classified under Building regulations Part L2a (i.e. required to complete SBEM assessments, but can account for some SAP assessed spaces where associated with the project) As a rule of thumb, if the building contains rooms rather than self-contained flats or homes, a BREEAM Multi-residential assessment would probably be most appropriate. We are aware of some confusion over the meaning of the term ‘multi-residential’ in this context and will be considering the use of term as part of the next review of the BREEAM Multi-Residential scheme. If you are unsure of the appropriate scheme classification for a particular project, please contact the BREEAM office before registering the project.
11-Nov-2025 - Applicability to current UKNC, HQM and UKNCR confirmed