WAT 06 - Water efficient equipment: appliances

Information correct as of 10thNovember 2026. Please see kb.breeam.com for the latest compliance information.

Converting water consumption into litres per year from new EU energy labels - KBCN1548

The following conversion factors may be used to convert the water consumption on new EU energy labels from litres per cycle (L/cycle) into litres per year (L/year): Dishwasher: multiply water consumption figure on EU energy label by 280 (to go from L/cycle to L/year). Washing machines: multiply water consumption figure on EU energy label by 220 (to go from L/cycle to L/year). This follows equivalent guidance for converting energy consumption (see KBCN1462).
25 Aug 2023 - Correction to 'typo error' for dishwasher conversion factor - previously shown as 208, now corrected to 280.

Washer dryers - KBCN0699

Where a washer dryer is specified, the water consumption figure for the wash and dry cycle should be used. The drying cycle of a washer dryer is taken into account because it usually uses water during this drying process (e.g. for cooling during the drying cycle) and in some cases, this water usage can be significant.
18-Nov-2022 - Updated to apply to BREEAM In-Use Version 6

Washing machines and dishwashers – Water consumption data - KBCN1571

The water consumption data used to demonstrate compliance may be based on the lowest full wash cycle (i.e. not a pre-wash cycle, for example).