In-Use / BIU International Residential V6 / Part 1 / 06 - Resilience /

RSL 05 - Alarm systems

Information correct as of 19thNovember 2026. Please see kb.breeam.com for the latest compliance information.

Alarm systems – Intent of Criterion 2 - KBCN1707

The intent of Criterion 2 is as follows: A documented plan is in place to ensure that when the alarm is triggered, whether due to a fire or security incident, a system fault or a false alarm, building staff and occupants understand what actions to take. This must include any necessary communication with ARC staff, emergency services and other building users. This clarification will be incorporated in the next update of the technical standard.
29 April 2025 - Due to the ambiguity of the guidance in technical manual, where project teams demonstrate that the assessment documentation was prepared prior to the publication of this KBCN, and that the wording of criterion 2 in the technical manual has been followed, this KBCN can be disregarded.

Intruder alarm systems – apartment buildings or similar - KBCN1572

Scope The scope of this KBCN applies to any residential asset that: A typical example is an apartment building. Principle The asset as a whole is protected by systems that are fit for purpose to ensure the safety and security of the asset, its users and their property Implementation Security requirements for apartment buildings will vary greatly depending on factors such as: Because of this, BREEAM cannot provide specific guidance on how intruder alarms and access control are configured to meet the principle. It is the role of the assessor and a competent third party (for instance, this can be a 'competent person' as defined in Rsl 10) to evidence how this principle is achieved for the asset as a whole. Evidence from a compliant security risk assessment carried out in line with Rsl 10 can be used to support this issue. Management-based solutions As a Part 1 issue, this intent must be achieved by systems which are intrinsic to the asset. Management-based solutions (such as a concierge service, or security guards) cannot be used to achieve answer E (intruder alarm systems). Answer F (alarm receiving centre) can only be achieved with a system that complies with Answer E.

Intruder alarms – Requirement for these to be audible when activated - KBCN1597

Where it is justified by the security consultant, project team or building management that a 'silent' intruder alarm system is more suited to the asset’s overall security strategy, this can be considered as meeting the Definition in our guidance.