In-Use / BIU International Commercial V6 / Part 2 / 02 - Health and Wellbeing /

HEA 19 - Drinking water management

Information correct as of 27thNovember 2026. Please see kb.breeam.com for the latest compliance information.

Applicability – no occupied spaces - KBCN1551

Principle Where: Credits specifically related to occupied space are not awarded. Outcome The tables below show how this principle applies to affected issues.
Issue Credits available Scope
Part 1
Hea 01 Daylighting Y Only answer C is available.
Hea 02 Control of glare from sunlight N
Hea 03 Internal and external lighting levels N
Hea 04 Lighting control N
Hea 05 Minimising flicker from lighting systems Y
Hea 06 View out N
Hea 07 User comfort control N
Hea 08 Y
Hea 09 N
Hea 10-13 Y
Part 2
Hea 14 Thermal comfort N
Hea 15 Smoking policy Y
Hea 16 Indoor air quality management Y
Hea 17 Acoustic conditions N
Hea 18 Legionella risk management Y
Hea 19 Drinking water management Y
16-Jul-2026 - Hea 09 corrected.
16-Dec-2022 - KBCN title and scope updated for better visibility. Error in Hea 03 amended. Applicability of KBCN applied only to affected issues (N, or modified answer options) with to minimise header space in the UI. Original content on Resources moved to new KBCN.
27-Nov-2025 - KBCN applicability updated to include all Hea credit issues.
 

Provision of fresh drinking water – Atmospheric water generators - KBCN1674

Atmospheric water generators can be used as an alternative to point-of-use water coolers connected to the mains water supply and drainage where it can be demonstrated that the water provision: In this situation the water supply does not need to be connected to the mains water supply and drainage. Suitable access provision in areas must still be demonstrated.
Information correct as of 27thNovember 2026. Please see kb.breeam.com for the latest compliance information.