Emergency lighting - KBCN0185

Maintained systems featuring emergency light fittings which are also used for normal operation, are assessed for this issue. Non-maintained lighting which is only activated in an emergency can be excluded from the assessment. NC / RFO / BIU V6 Ene 17: The aim of these credit(s) is to encourage and recognise energy-efficient fittings. Non-maintained emergency lighting will very rarely be activated and in such extremes the emergency requirements must not be compromised. BIU V6 Hea 05: Flicker is eliminated from maintained systems only.
24-Jan-2024 - Scheme applicability updated to include BIU V6.

External lighting – Residential balconies and terraces - KBCN1507

Where an external balcony or terrace serves a single dwelling and is accessed directly from the dwelling, the requirements for lighting controls for the external lighting serving this space are not applicable. Such spaces are owned and controlled by the occupant and should be considered in the same way as internal lighting.
05 Nov 2024 - Not applicable to BREEAM NOR

RGB LED lighting - KBCN0986

RGB LED lighting must be assessed against the average external lighting efficacy benchmark. The current criteria do not completely rule out the use of RGB LED lighting as it can potentially be combined with other types of external lighting to meet the average efficacy benchmark.