Alarm systems – Intent of Criterion 2 - KBCN1707

The intent of Criterion 2 is as follows: A documented plan is in place to ensure that when the alarm is triggered, whether due to a fire or security incident, a system fault or a false alarm, building staff and occupants understand what actions to take. This must include any necessary communication with ARC staff, emergency services and other building users. This clarification will be incorporated in the next update of the technical standard.

Amenities – Community facility – Collaborative work areas (shared workspace) - KBCN1918

For appropriate building types, a collaborative work area can qualify as a community facility where it is demonstrated that:

Approved Equivalent Roles List (AERL) - KBCN1809

BREEAM International standards are unique because of their flexibility. For International projects, Assessors can submit roles to substitute those described in the Technical Manuals. Provided that such roles are equivalent to the BREEAM specified roles, BRE Global will approve them for use in a particular country or region. The Approved Equivalent Roles List is a record of all roles that BRE Global has approved to date. The list is periodically updated to reflect recent approvals or withdrawals. Using existing approved roles Where you are using an approved role, and not the role described in the criteria in the scheme Technical Manuals, a copy of the AERL should be included as part of your evidence submission for QA. AERL versions The version of the AERL that is current at the time of registration is the one that is used for assessment. Newer versions released after this can also be used, however older versions before the registration date cannot be used. For example: if the version current at registration was v3.0, then v3.0 (or any later versions) can be used, but v2.0 (or any earlier versions) cannot be used. Proposing new roles New roles cannot be proposed if they are not of equal competency to the BREEAM requirements. Only roles which are equivalent or more rigorous than the BREEAM default roles are considered. If you wish to propose a new role which you think is equivalent in your country or region:
  1. Check what the role needs to cover by referring to the roles described in the scheme Technical Manual definition.
  2. Complete BF2599 BREEAM Approved Equivalent Roles Application Form and send this to our Technical Team via the Query Webform, adding AERL into the subject field.
The information provided to us within this form must include: We will need a few weeks to review the information (please check with us for time scales). If there is missing information, or the information is not clearly referenced, this might take longer. If successful, we will send you a revised copy of the AERL which includes the new role, and will update this for future versions of the AERL.

Assessing multiple residential buildings - KBCN1687

BREEAM In-Use has been developed as an environmental assessment method to assess existing assets. Typically, an asset consists of a single building or part of a single building. However, BREEAM In-Use provides an exception where certain criteria have been met, and this is set out in the relevant Technical Manual under the Eligibility Criterion 5 and reproduced below with clarifications noted in Italics. The requirements to assess multiple buildings as a single asset Criterion 5 states: An asset cannot normally include more than one building. The only exception is where several buildings meet the following criteria:

a) All buildings must be located on the same site. The site boundary must be drawn where responsibility for management or ownership of the site changes. For multifamily assets, this means all structures within the property boundary. For individual homes, e.g. single family, townhouses, this means the properties on which the homes are located are contiguous.

b) All buildings must have the same building function, similar performance, and be of similar design and age. Multifamily projects, such as garden style apartments, can still be grouped together under these criteria, even if they include different unit types.

c) Building management and maintenance policies, procedures and approach must be the same across all the buildings that make up the asset to ensure consistent implementation. Where maintenance policies, procedures, and approaches are the tenant’s responsibility through the leasing arrangements, these can vary, but overall building management needs to be the same for all properties

d) Evidence must be collated from each building that is included in the asset and where performance against the BREEAM requirements varies, the final score will be determined by the space with the lowest level of performance. The whole data set for all buildings in the assessment must be gathered and provided to the Assessor by the Client.

  Demonstrating compliance for certification Considerations before undertaking this approach

Asset classification – co-living developments - KBCN1568

This guidance is intended as a general reference only. Each co-living development will include a different combination of residential accommodation and managed communal spaces. Assessors must apply professional judgement to determine the most appropriate asset classification. Typical characteristics of co-living developments Developments within these sectors typically include the following characteristics: Classification guidance The following classifications are recommended:
Assessment Type Recommended Classification
International New Construction, International Refurbishment and Fit-Out and Refurbishment and Fit Out Commercial V7 Residential institutions- long term Stay*
BREEAM USA In Use (BIU) Residential
*Assessors should also consider how the asset is classified under relevant local building regulations to support the interpretation of Residential Institution.
16 July 2026 - Applicability clarified and wording updated
17-June-2026 - Guidance revised and updated for clarity

Benchmark energy performance value – clarification - KBCN1724

The benchmark energy performance value is a performance level which achieves the median performance within a local energy performance standard's range of values. Example The asset is being benchmarked using the Energy Star Portfolio Manager. Under this system, assets can receive a score from 1 to 100. A score of 50 represents median performance, which equates to the benchmark energy performance value.
27-Mar-2025 - Published.

Carbon dioxide sensors – Alerts - KBCN1868

Criterion 1 requires CO2 sensors to: 'Visibly or audibly alert the asset owner or manager or users of the space when carbon dioxide levels exceed the recommended set point.' This requirement can be met by an automatically generated email or other message format, provided it is demonstrated that such messages will be delivered to the appropriate person/people within a reasonable time. This meets the intent of the criterion and may, in some cases, be a more appropriate solution.

Carbon monoxide detection – Combustion appliances located outside - KBCN1586

Where all combustion appliances are located outside in the open air, no flues pass through an occupied space and there are no enclosed parking areas, the associated credits can be filtered out as per Criterion 1

Clarification – percentage of end uses - KBCN1650

This percentage is measured by the energy consumption (kWh) of significant energy uses, not by the number of end uses.

Clarification – reasonable timescale for refrigerant replacement - KBCN1733

If the asset targeting Answer D with a future commitment to replace refrigerants, these must be replaced within 3 years. BREEAM In-Use assesses the current performance of an asset, and does not recognise far-future commitments. 3 years is the period of a single BREEAM In-Use certification cycle, and it is intended that any replacements are made during this current cycle.
28-Apr-2025 - Published.

Combined system for heating / cooling and domestic hot water - KBCN0329

It is permissible to have combined metering for a shared on-site or district system that combines heating / cooling, and domestic hot water generation. In all cases, justification is provided in the QA report for the combined metering, and explains why it is not technically feasible to provide separate meters.
21-Sep-2022 Applicability of KBCN added to BIU V6. Amended to include district heating and cooling networks.

Condition survey – refurbishment in the last 5 years - KBCN1522

Where an asset has been refurbished, refurbished elements listed in criterion 2 can be excluded from the condition survey if: The intent of Rsc 01 is to give asset management a complete understanding of the condition of the asset. The requirement for 5 years is to make sure that this information is relatively up-to-date, and allows effective maintenance of the asset and management of any minor defects. All example scenarios below assume that the refurbishment was carried out less than 5 years ago. Any refurbishment works carried out more than 5 years ago must follow the full criteria of this issue. [accordion] [accordion_block title="Scenario 1"] A major refurbishment to a Commercial asset covered and effectively documented refurbishment to: a. Structure. b. Mechanical components. c. Electrical components. d. Plumbing. e. Fire protection. It did not cover: f. Communications and life safety systems. g. Health and safety conditions. All major defects were resolved. Credits for the condition survey, and for rectifying defects are awarded based on elements f. and g. only. [/accordion_block][accordion_block title="Scenario 2"] A major refurbishment has covered and documented all items in criterion 2. All major defects were resolved, but there are some outstanding minor defects that are being monitored and maintained by asset management. BIU V6: This issue is filtered out as per criterion 1. BIU 2015: The relevant credits are awarded. Minor defects are common after major building or refurbishment works, and typical building contracts provide a period for the resolution of minor defects. As long as major defects are resolved by the refurbishment, and asset management are aware of and managing minor defects, these items can be excluded from the condition survey. [/accordion_block][accordion_block title="Scenario 3"] A major refurbishment covered all elements, but there is no record of the refurbishment of mechanical and electrical components. A condition survey covering these items is required. Relevant credits are awarded for surveying and addressing any defects for these elements. [/accordion_block] [/accordion]

District heating / cooling / hot water – entering data into the Online Platform - KBCN1536

For assets which use district heating / cooling / hot water, information on the district systems are entered into Ene 09a and 09b. In Ene 05 / 06 / 09, answer 'no' to first question "Is space heating / cooling / hot water generated on-site?" then navigate to: The Online Platform differs from the manual structure, however it does not affect scoring in any way. All data entered contributes to the asset energy calculator. Assets with on-site and off-site systems Only answer questions on the system which provides the most signifcant heating or cooling to the asset. If an asset includes both on-site and off-site systems, choose the one which delivers the most energy annually.

Ecological features – Answer D – Planters and planted areas - KBCN1543

Outdoor planters and traditional planted areas can be considered as one feature for the purposes of Answer D, provided there is enough planting on the site to meet the intent of the issue. To meet the requirements of Answer D, the following must be demonstrated:
20-Dec-2023 – The intent of this KBCN was to simplify compliance with Answer D. This has now been updated to clarify that it only applies to Answer D, thereby removing the potentially negative impact on meeting the requirements of Answer C.

Electric vehicle charging stations – faster charging - KBCN1497

The number of electric vehicle charging stations required for compliance cannot be reduced by installing faster/higher power charging stations. This would not necessarily increase the availability of the charging stations for users.

Eligibility criteria – BIU USA Residential V6 - KBCN1668

The Eligibility Criteria for BIU V6 Residential have been updated, and the guidance below supersedes Criterion 2 in the V6.0 technical manual: Criterion 2)

a) Submission for certification must be a minimum of 12 months from completion of the dwellings.

AND

b) For a Part 2 assessment, 12 months’ utility consumption data must be available for a minimum of 80% of the dwellings.

AND

c) The asset must be intended to be a primary residence of the occupants.

 

Energy consumption reporting – Link to Man 04 - KBCN1612

The link to meeting compliance with Man 04, outlined in Ene 23 Criterion 1 is incorrect and should be disregarded. Answer option D in Man 04 includes targets for Energy, Water and Waste. Whereas the intent of Ene 23 relates to targets for Energy only. This will be updated in the next reissue of the technical manual.

Enhanced waste collection in the asset - KBCN1528

Where the asset collects 6 or more unique residential waste streams on-site, answers G and H are available without the need for additional off-site collection points. If the asset can provide enhanced waste collection and sorting on-site, then this is effectively the same as having a compliant collection point in the local area. Example scenarios [accordion] [accordion_block title="5 waste streams on-site"] An apartment building has compliant facilities or kerb-side collection for 5 residential waste streams. There is no collection for composting or garden waste. The asset achieves the requirements for answer C only if all relevant criteria are met. There aren't enough waste streams to meet the threshold for answer G. [/accordion_block] [accordion_block title="7 waste streams on-site"] An apartment building has compliant facilities or kerb-side collection for 7 residential waste streams. There is no collection for composting or garden waste. The asset achieves the requirements for answer C, and answer G if all relevant criteria are met. [/accordion_block] [accordion_block title="7 waste streams on-site, with off-site collection point within 0.3 miles"] An apartment building has compliant facilities or kerb-side collection for 7 residential waste streams. There is no collection for composting or garden waste. An off-site collection point within a compliant distance can collect 5 waste streams, however only 2 are unique (different from what the asset already collects on-site). In total there are 9 unique waste streams collected on-site, kerb-side, or within a compliant distance. The asset achieves the requirements for answer C, and answer H if all relevant criteria are met. [/accordion_block] [/accordion]

Erratum – scope of issue - KBCN1498

Criterion 1 states: "Where external lighting or car park lighting are not necessary from a safety perspective, the associated credits can be filtered out of the assessment." What this means is: The inclusion of the word 'safety' in this criteria is misleading and will be removed in future versions.
28-Feb-2024 - Wording clarified.

Erratum – up to V6 – methodology – no default energy assumptions - KBCN1630

The scope of the issue applies only to systems with significant energy use. The methodology section states that the online platform will calculate default values, and use this to indicate which systems are in scope. This is incorrect, as default values are not automatically calculated. The energy use of each system will need to be manually estimated. This can be done based on:

Erratum – up to V6.0.0 – compliant cycle storage - KBCN1595

Criteria Instead of answer C, criterion 3 should refer to answers D and E. Evidence The criteria references for this issue are incorrect, and will be corrected in the next re-issue. Checklists and tables The headings in Table 20 do not match these answers. Table 20 will be revised with these updated headings:
Home size Answer D Minimum cycle storage 2 credits Answer E Additional cycle storage +1 additional credit
Studio or 1 bedroom 1 cycle space / 2 homes 1 cycle space / home
2 - 3 bedrooms 1 cycle space / home 2 cycle spaces / home
4+ bedrooms 2 cycle spaces / home 4 cycle spaces / home
 

Erratum – V6.0.0 – cooling efficiency parameter – EER / SEER - KBCN1560

In the asset energy calculator guidance, the parameter given for cooling efficiency is 'SEER' (Seasonal Energy Efficiency Ratio). This is incorrect and should say 'EER'. This affects the following tables:
International USA
Commercial V6.0.0 Table 19 Table 18
Residential V6.0.0 Table 16 Table 16
This will be updated in the next manual re-issue.

Erratum – [BIU V6 Rsl 06] – Incorrect evidence requirements for answers G – H - KBCN1696

Please note that the requirements for the report to include 'opportunities identified' and the 'key metrics' does not align with the criteria requirements. This can therefore be disregarded. This will be updated in the next reissue of the manual

Erratum – [BIU V6.0.0 Wat 14] – Incorrect evidence requirements - KBCN1695

The criterion 3 evidence requirement, "evidence of monitoring data" is incorrect and invalid. Assessments should not try to meet this requirement. Criterion 3 requires the water strategy to have senior management approval. This has no relation to monitoring water consumption, which is already addressed in Wat 13 Water consumption reporting. This error will be addressed in future updates.

Erratum – Electric Vehicles (EV) charging stations criteria - KBCN1701

In the BREEAM In-Use International Technical Manual, the  Electric Vehicles (EV) charging criteria and their evidence were incorrectly referenced. The requirements for EV charging stations should read as follows Answer G Electric Vehicles (EV) charging stations are provided for ≥5% of the car parking capacity. Methodology The methodology indicates the number of charging stations required should be calculated as a percentage of the total car parking capacity.  The ≥5%  in Answer G indicates that at least 5% of the total parking spaces in the residential development should be equipped with EV charging stations. If the number of charging facilities that should be supplied is not a whole number, it must be rounded up to the nearest whole number. For example, where the number of charging facilities that should be provided is calculated to be 10.2, the actual number of facilities that must be provided is 11. Charging stations for Car Clubs cannot count towards the percentage provided for residents. Evidence The manual incorrectly referred to criterion 7 for the EV charging stations in the evidence section. The evidence requirement should refer to Criterion 5 and should be read as follows:
Criterion Evidence requirement

5

Calculations showing the percentage and number of charging stations

5

Site plan showing the location and number of electric vehicle charging stations
 

Evidence of no risk – Use of Approved Standards and Weightings List - KBCN0959

The current BREEAM International Non-Domestic New Construction Approved Standards and Weightings List (ASWL) can be used as evidence to demonstrate that a country has ‘no risk’ to all natural hazards apart from flooding (which is considered within POL 02 of BREEAM USA In-Use 2016 and Rsl 01 of BREEAM In-Use Version 6). Any country which has a weighting of 0% for Hazards within the current ASWL (within Weightings INC 2016 and V6 tab) can provide this to BRE Global as evidence. As flooding is not included within the Hazard section of the ASWL, it must be evidenced separately. Therefore, in order to achieve maximum credits within MAT 05 or Rsl 03, the assessment must also provide evidence that the asset is in a ‘low or zero flood risk area’ under the requirements of POL 02 (BREEAM USA In-Use 2016) or Rsl 01 (BREEAM In-Use Version 6). Note: BREEAM In-Use International Assessors who are not BREEAM International Non-Domestic New Construction Assessors, will be unable to access the ASWL. In this instance please send a technical query to BRE Global outlining the country which the asset is located, and BRE Global can confirm the current weighting for that country.
18-Aug-2025 added '(within Weightings INC 2016 and V6 tab)' to clarify where in the ASWL the weightings can be found
16-Aug-2016 Amended to clarify situations where there is no access to the ASWL
01-Oct-2022 Updated to apply to BREEAM In-Use Version 6
 

Fire hydrants and sprinklers – Leak detection - KBCN0680

Where it is confirmed by an appropriate project team member that it is not possible to fully meet the leak detection criteria for fire hydrants or sprinklers, an alternative approach can be implemented for these systems. This must demonstrably meet the aim of the issue by detecting and alerting the building management to major water leaks.    
11 Sep 2024 - Applicability to BIU USA V6 and INC V6 confirmed. New guidance introduced to clarify that BREEAM compliance should not compromise the operation of building safety-critical systems.

Flood risk – use of flood maps only in FRA - KBCN1524

Answer option E (Commercial) or F (Residential) If a flood risk assessment considers flooding from rivers and seas only, flood risk is zero / low, and the following requirements are met: It is acceptable for the flood risk assessment to be carried out by a relevant member of the team. It does not require a competent individual (see manual definition) to do this. Most sources of flooding are site-specific and require specialist input and calculation to quantify. However, flood maps meeting the criteria above can provide an acceptable level of assurance of overall flood risk from rivers or seas without the need to engage a specialist. Answer option B (Commercial) or C (Residential) Where the risk of flooding is medium or high, flood mitigation measures are required (criterion 3). These mitigation measures must be defined by either: The FRA can still be produced by a relevant member of the team. Relevant member of the team A ‘relevant member of the team’ would typically refer to an individual directly involved with the management and operation of the asset, such as the building owner, client, tenant (if they have management responsibility), or the facilities/building manager. The aim is to ensure the flood risk assessment is carried out by an appropriate party to inform the owner/management about the flood risk to the property, whilst upholding the independence of the BREEAM Assessor for verification. The relevant person cannot, therefore, be the BREEAM assessor, as they must be impartial and cannot produce evidence which they then verify for compliance. If another person in the assessor organisation were to undertake this role, it would need to be demonstrated how potential conflicts of interest would be managed - see KBCN1708 Exemplary credit This option is only available if a site-specific FRA was carried out by a competent individual, and cannot be based only on flood maps that give an allowance for climate change. Example scenarios [accordion] [accordion_block title="Low / zero flood risk"] National flood maps cover flooding from rivers and seas. The flood risk from these sources is zero / low. The compliant FRA can be produced by a relevant member of the team. [/accordion_block] [accordion_block title="Medium / high flood risk"] National flood maps cover flooding from rivers and seas. The flood risk from these sources is medium / high. Flood mitigation measures are required. The local authority provides some general flood mitigation measures for the area, but these are not relevant to the assessed asset. Instead, a competent individual is consulted on relevant flood mitigation measures for the asset - their recommendations are recorded in the FRA. The compliant FRA can be produced by a relevant member of the team. [/accordion_block] [/accordion]
19-Jun-2025 - Relevant member of the team - Definition added
06-Nov-2024 - Answer C guidance title now corrected to point to Answer B for Commercial manuals.

GN26 Representative sampling methodology for assessor site inspections - KBCN1914

Latest version: v0.0, September 2026  Guidance Note 26 (GN26) provides information to BREEAM In-Use assessors on how to use representative sampling during site inspections. It aims to help assessors carry out a proportionate, risk-based inspection strategy without needing to inspect every building, apartment, or element.  This guidance may be used at the assessor's discretion to support decisions regarding sampling during site inspections for BREEAM In-Use.  Download Guidance Note 26 (licensed assessors only) View all Guidance Notes on BREEAM Projects (licensed assessors only)
24-Sep-2026 - KBCN reinstated

Inclusive design – Access4you  - KBCN1826

BREEAM recognises the use of Access4you certification as an approved alternative to the credits available in Hea12 Inclusive design as set out below:

Hea 12 Inclusive design Access4you
2 credits Bronze level
4 credits Silver level or higher

Evidence of Access4you certification must be provided at the final BREEAM certification stage.

AboutAccess4you

Access4you International is an organization that evaluates, certifies, and qualifies the accessibility of the built environment. Their self-developed criteria system consists of 1000 aspects, which are based on the usability aspects of 8+1 stakeholder groups, including people with special mobility, visual, hearing, and cognitive needs. The rating system consists of Certified location, Bronze, Silver, or Gold qualifications.

Access4you has two schemes, the Design & Building certification scheme which is aligned with a new construction or major refurbishment project and the Building certification scheme which is aligned with an assessment of an existing building. The most appropriate scheme, advised by Access4you should be used for certification.


Installed controls – ‘Asset does not have both heating and cooling’ - KBCN1678

In the technical manual, the intent is that Q1, Q2 and Q3 allow the credits to be filtered where the asset has 'neither heating nor cooling', in line with the assessment tool. This will be updated in the next reissue of the technical manual.

Interlock controls – clarification - KBCN1491

An interlock is a control that is wired so that when there is no demand for heating / cooling in a space, the heating / cooling generator and the associated pumps are switched off. Use of thermostatic radiator valves (TRVs) alone does not provide interlock. Partial interlock means that the cooling and heating interlock controls are separate. However, the control function may be set up to minimise the possibility of simultaneous heating and cooling. Total interlock means the controls are wired so that simultaneous heating and cooling is not possible. Where there are separate local heating or cooling units present, these will also need to be wired into the control system for total interlock to avoid the possibility of simultaneous heating and cooling.

Intruder alarm systems – apartment buildings or similar - KBCN1572

Scope The scope of this KBCN applies to any residential asset that: A typical example is an apartment building. Principle The asset as a whole is protected by systems that are fit for purpose to ensure the safety and security of the asset, its users and their property Implementation Security requirements for apartment buildings will vary greatly depending on factors such as: Because of this, BREEAM cannot provide specific guidance on how intruder alarms and access control are configured to meet the principle. It is the role of the assessor and a competent third party (for instance, this can be a 'competent person' as defined in Rsl 10) to evidence how this principle is achieved for the asset as a whole. Evidence from a compliant security risk assessment carried out in line with Rsl 10 can be used to support this issue. Management-based solutions As a Part 1 issue, this intent must be achieved by systems which are intrinsic to the asset. Management-based solutions (such as a concierge service, or security guards) cannot be used to achieve answer E (intruder alarm systems). Answer F (alarm receiving centre) can only be achieved with a system that complies with Answer E.

Intruder alarms – Requirement for these to be audible when activated - KBCN1597

Where it is justified by the security consultant, project team or building management that a 'silent' intruder alarm system is more suited to the asset’s overall security strategy, this can be considered as meeting the Definition in our guidance.

Labelling of waste containers - KBCN1831

Strategies may vary according to the specifics of each project, their waste streams and collection arrangements. The aim of these requirements is to encourage recycling, ensuring that it is correctly sorted and to prevent cross-contamination of waste streams.

Leak detection – compliance principle – alternative technologies - KBCN1566

Where it can be demonstrated that alternative water leak detection technologies can meet or exceed the capabilities of systems set out in the BREEAM guidance, subject to approval, these can also be considered compliant. It is the role of the Assessor and the project team to provide evidence and justification in a compliance principle query (see KBCN1555). The following alternative solutions are currently recognised:
06-Jul-2026 - Title updated for consistency. Scheme applicability updated. Principle also applied to refrigerant leak detection.

Leak detection – using a BMS - KBCN0439

A BMS can be used for leak detection if it can be shown that its integrated or add-on features meet all the requirements for a leak detection system.
07 Feb 2022 - Applicability to BIU USA Commercial V6 confirmed

Lift or escalator efficiency – Manufacturer’s product data - KBCN1870

Where manufacturer’s product data showing the rated efficiency class is available, this can be used as evidence of meeting the required energy efficiency class stated in the technical manual. Additionally, the following supporting evidence must be provided:

Local energy performance asset rating – Validity period - KBCN1913

If an energy performance asset rating is currently valid at the time of measurement, it is valid for this issue. It does not need to be obtained specifically during the current assessment cycle.  For example, if an asset obtained a compliant rating in 2020 which is valid until 2030, this can be used in a current measurement in 2027. 
24-Sep-2026 - KBCN reinstated

Local energy performance asset rating – Whole asset not covered - KBCN1912

The energy performance asset rating does not need to cover the whole asset. However, it must cover all occupied areas of the building. 
24-Sep-2026 - KBCN reinstated

LZC – Local regulations and private wire arrangements - KBCN1658

Where local regulations do not permit electricity generated by on-site renewables to be connected directly to the building, and where evidence of the relevant regulations is provided at QA, the requirement for a private wire arrangement can be waived.

Methodology – Procedure for measuring illuminance - KBCN1721

The following guidance, found in the Methodology section of BIU USA V6 Commercial, can also be applied to BIU USA V6 Residential assessments: For assets with identical lighting systems and floor layouts across multiple areas or floors, illuminance levels in a representative sample of areas or floors may be measured, if in the professional opinion of the suitably qualified person, these are likely to give measurements that reflect the performance of the lighting in all relevant spaces within the asset. Illuminance measurements must be taken at least every five years and after any changes to lighting systems. Where the asset is less than five years old and illuminance levels were assessed as part of the design or construction of the asset that demonstrate compliance with the criteria in this assessment issue, then the results of these studies may be used as evidence (assuming there have been no changes to the lighting systems in the intervening period).

Minimising flicker – scope of issue - KBCN1639

Principle Flicker from all lighting systems is eliminated. This means eliminating flicker in: Only emergency lighting is excluded. See KBCN0185. Lighting flicker is undesirable regardless of location or length of exposure. Commercial scope Eliminate flicker in all lighting. Residential scope Eliminate flicker in:

Minimizing watercourse pollution – Areas to be assessed - KBCN1633

Criterion 2 should be interpreted as follows: The intent is to provide a list of areas that are likely to present a risk of watercourse pollution. All the listed areas must be considered, however, where a listed area is not present, or it is present but poses no risk of watercourse pollution, this should be justified with supporting evidence. Where the development does not include any of the listed areas, or none of the areas present poses a risk of watercourse pollution, justification and evidence must be provided and this issue should be filtered out, in line with Criterion 1.  

ModeScore Sustainable Transport certification - KBCN1705

Achieving ModeScore Gold or Platinum certification may be used as supporting evidence to award credits for the Transport issues listed in the table below. This alignment is permitted provided that the BREEAM technical criteria are demonstrably met.
Scheme Issues Credits Achievable via ModeScore
BREEAM International NC 2016 and V6 Tra 03a Alternative modes of transport 2 + Exemplary credit
Tra 03b Alternative modes of transport 2 + Exemplary credit
Tra 04 Maximum car parking capacity 1
BREEAM UK NC 2018 and V6 * Tra 02 Sustainable transport measures 10
BREEAM Int RFO 2015 Tra 01 Sustainable transport solutions 5
Tra 04 Maximum car parking capacity 2
BREEAM UK RFO 2014 Tra 01 Sustainable transport solutions 3
Tra 03 Cyclist facilities 2
Tra 04 Maximum car parking capacity 2
BREEAM In Use Commercial and Residential (International and USA) Tra 01 Alternative modes of transport 8
Tra 02 Proximity to public transport 3
Tra 04 Pedestrian and cyclist safety 2
BREEAM UK NC Residential V6.1* 1.1 Public transport availability 3
1.2 Sustainable transport options 17
Evidence Requirements To award credits using this route, the Assessor must:
  1. Submit the ModeScore Certification and Assessment Report.
  2. Provide a mapping statement demonstrating how the targeted BREEAM criteria have been met using the relevant ModeScore criteria.
  3. Provide any Supplementary Evidence identified through the mapping process.
Scheme-Specific Provisions*
About ModeScore Sustainable Transport certification:
ModeScore assess and certifies sustainable transport facilities and services in buildings. ModeScore encompasses ActiveScore within its assessment criteria, covering four pillars of sustainable transportation while incorporating accessibility into each: ModeScore evaluates the connectivity potential of any building, anywhere, offering four levels of certification and a total scorecard of 120 points. ActiveScore (Travel Facilities) counts for 10 points: See more information and details at https://modescore.com/

Multiple ratings in a single assessment - KBCN1725

Sometimes the boundaries for energy performance ratings for meeting building regulations are split in a different way to the BREEAM assessment boundary. If the BREEAM assessment boundary covers multiple energy ratings, for this issue only enter data on the rating which covers the largest NIA (Net Internal Area).
27-Mar-2025 - Published.

Night-time operation – requirement for controls - KBCN1048

Projects or areas of an asset which operate at night-time can adapt or omit the requirement to provide controls or presence detection to align with the building’s hours of operation. This could, for example, include service yards or car parks. The aim of this Issue is to reduce the energy use for external lighting and should not interfere with the building’s operation.
02 Oct 2024 - Updated to clarify the scope of the this guidance and applied to NC V6 and BIU.

Occupant control – spaces requiring user controls - KBCN0170

This guidance is intended to clarify the types of area for which user controls are required or would be considered beneficial. Zoning is required in all areas of the asset where specified in the assessment criteria. Please refer to the specific requirements of the applicable BREEAM standard to interpret this guidance appropriately. User controls required Spaces where users are expected to have independent control over their environment. User controls not required Spaces where users are not expected to have independent control over their environment.
14-Dec-2022 - KBCN applicability updated to include BIU. Wording clarified, and amended for compatibility with BIU criteria.

On-site LZC – whole site shared connection - KBCN1424

To be recognised in BREEAM, the on-site Low and Zero Carbon (LZC) technology must have a direct physical connection to the assessed asset. OR Where the LZC technology is; It is acceptable to allocate the renewable energy generated proportionally as a calculation of the asset's predicted energy consumption compared to the total energy consumption of the whole site. To allocate renewable electricity by proportional consumption: Where consumption data is missing, renewable electricity must not be allocated to the assessed asset. In this case, it is assumed that all electricity consumed is sourced from the grid.
17-Jan-2024 - Applicability BIU V6 Ene 13 removed, as this approach is not applicable to assessing the area of PV fitted.
21-Dec-2022 - Applicability to In-Use V6 confirmed.

On-site or curbside storage and collection – Additional recyclable residential waste streams - KBCN1722

Answer C rewards on-site or curbside storage and collection of recyclable residential waste streams. Answers G and H reward local storage and collection of additional recyclable residential waste streams. Where Answer C is met and further recyclable residential waste streams are available with on-site or curbside storage and collection, these can be considered under Answer G or H.

Presence detection – illuminated signs - KBCN1671

The requirements for presence detection do not apply to illuminated signs. In BIU V6, presence detection requirements are included as part of automatic energy saving controls. All other requirements in this criteria must still be met.

Recognizing future performance - KBCN1538

BREEAM In-Use recognizes an asset's operational performance at the time of certification. Compliance cannot be based on commitments to improve the performance of an asset in the future. Where changes to an asset are made during a 3-year certification cycle:

Refrigerant charge – issue filtering - KBCN1717

Criterion 1 states that if all systems have ≤11lbs refrigerant charge, this issue is filtered out. In the asset, there may be a mixture of systems above or below this threshold. In this scenario, this issue still applies to all other systems with >11lbs refrigerant charge. All systems with refrigerant charge ≤11lbs are excluded from assessment, but if other systems are still in-scope, this issue still applies.
11-Feb-2025 - Published.

Residential eligibility criteria – clarification on occupancy levels [superseded] - KBCN1523

01 Nov 2014 This guidance is now superseded. Please refer to KBCN1668

Resources inventory – Scope - KBCN1667

The inventory only needs to include resources that belong to the asset owner (or those which the asset owner or manger is responsible for maintaining or replacing). It does not need to included tenant-owned fittings and furnishings

Risk assessment – flooding is the only natural hazard - KBCN1552

Where: then Answer D ('the asset is in an area where no risks exist') is only available where the FRA shows zero or low flood risk from all sources of flooding listed within criterion 1 of RSL01 with the exception of: d) Groundwater: most common in low-lying areas underlain by permeable rock (aquifers) e) Sewers: combined, foul or surface water sewers Assessing flood risk from rivers and seas only does not cover all risks.
13 November 2025 Updated to exclude groundwater and sewers from the requirements for Rsl03.

Safe pedestrian routes – Definition, measurement and verification - KBCN0238

Definition Safe pedestrian routes include sidewalks and safe crossing points, which may be controlled or, for example, be identified by tactile paving, a crossing island or a dropped curb. An element of judgement may be required, in which case justification should be provided. Measurement Distances could be measured, for example, along a sidewalk, across a road at a safe crossing point and along the sidewalk on the other side.  The distance should not be measured diagonally across a road, following the most direct route. Verification The assessor’s site inspection is an important aspect of the assessment and may help to confirm that all relevant information is current and can include photographs of any key areas. This can also help to identify safe crossing points or hazards which may not be apparent from a desktop study. However, web-based evidence may also be used where the assessor is satisfied that it is robust and demonstrates that it is up to date. Where web-based navigation maps (e.g. Google Maps/Street View) are used as supporting evidence, this must include: • Dated and marked-up site plan or a web-based navigation map viewer highlighting: • Current location and type of transport nodes and local amenities. • Current route and distance from the building via a safe pedestrian route. • Plan or map scale. When using web-based evidence for post-construction stage, the assessor must, additionally, provide verification that the information provided for the nodes/amenities is still accurate and up to date.
29 Aug 2025 - Approach to web-based map data at post-construction stage updated and related wording amended accordingly
07 Mar 2024 - No changes have been made. This appears as 'updated' due to an administrative error.
11 Jan 2024 - Wording re-structured for clarity
19 Dec 2023 - Applicability to BIU V6 confirmed

Shared secondary containment – Capacity - KBCN1885

For secondary containment storing two or more hazardous chemical containers/tanks, adequate containment is demonstrated where capacity is at least the greater of: For a single container/tank, containment must be at least 110% of that container/tank capacity. Hydraulically linked tanks must be treated as a single tank. Where local regulations or site-specific risk controls require a more stringent containment volume, these take precedence.

Shower with multiple shower heads - KBCN0855

To calculate the water use of a shower with more than one shower head, one of the following should be done:
22 Feb 2024 - Applied to BIU, BREEAM NC and RFO standards

Single and Multiple Certification options - KBCN1430

BIU Residential provides flexible options to allow as many residential buildings as possible to be rated and receive a certificate. These include: Apartments Houses   Benefits of the different certification options Multiple certificates – These show the performance of each residential unit. This can show the difference in scoring and rating between units, which could be used for sales purposes or as a way of targeting specific units for improvements. When opting for multiple certificates, the rating of the best performing units will not be limited by the performance in other units. Evidence must be collated from each building that is included in the assessment and where performance against the BREEAM requirements varies, the final score will be determined by the apartment or home with the lowest level of performance. Single Certificates – These show the performance of the apartment(s) or house(s) as a whole. While performance has to be documented for each dwelling, BREEAM Projects includes features which help streamline this process.   Which certification route is right for my Asset? When assessing just the Asset Performance in BREEAM In-Use Residential v6, the choice of certification option is up to the client. However, if Management Performance is included in the scope of assessment then the differing data requirements will determine which certification option the project needs to follow. These differing data requirements are driven by the energy consumption data available. The flow diagram below can be used as a guide to determine the appropriate certification route for your project, given the energy consumption data available. The scope of the energy data available will typically be more variable for an apartment building compared to houses. Houses tend to be individually metered, and therefore certification options are more open to client choice. Note: Any asset without compliant consumption data will not be able to achieve all of the credits within Management Performance (e.g. the Operational Energy Calculator and Water) If further assistance is required, please contact BRE at BREEAMInUse@bregroup.com
24 Apr 2024 - Paragraph headed 'Benefits of the different certification options' updated for clarity and KBCN applied to BREEAM In-Use USA Residential 
20 July 2021 Amended for clarification and flow diagram updated

Smoking policy – External areas - KBCN1680

The criteria do not require that the asset provide a designated external smoking area. The intent of Specific Note 1 is that the asset management encourage compliance with the no smoking policy by identifying areas where building users are not prohibited from smoking. However, where it is justified that no such areas can be identified within proximity of the asset, this requirement can be disregarded.

Sub-metering technologies – Compliance principle - KBCN1561

Where it can be demonstrated that alternative sub-metering technologies can meet or exceed the capabilities of systems set out in the BREEAM guidance, subject to approval, these can also be considered compliant. It is the role of the Assessor and the project team to provide evidence and justification in a compliance principle query (see KBCN1555). The following metering standards or technologies are currently recognized as alternatives to pulsed output meters:

Systems serving <10% overall floor area - other affected issues - KBCN1542

The methodology for Ene 01 states: "Heating / cooling systems can be excluded from the calculation where the heated or cooled area equates to less than 10% of overall floor area." Systems which heat or cool < 10% overall floor area are not assessed in: Ene 01, 05 and 06 all feed into the asset energy calculator and so their inputs must be consistent. All other issues relating to these excluded systems are still assessed such as:

User controls – Thermal comfort - KBCN1813

The requirement for user controls does not mandate a specific type of control; e.g. local manual adjustment. Where control is provided indirectly, e.g. via BMS or central management, the assessor must demonstrate that this approach meets the intent of the user comfort and accessibility criteria and is informed by end-user discussions or relevant design guidance. Please refer to KBCN0170 for clarification of the types of space requiring user controls.

Using water from natural underground sources to offset water consumption - KBCN00094

Water from natural underground sources (for instance aquifer water accessed via boreholes) cannot be used to offset: A significant amount of water used for public consumption is already drawn from aquifers. Private boreholes may be drawing water from the same sources as public utility companies.
27-Mar-2024 - Title and text updated to broaden definition. Scheme applicability updated.

Verification of Security Needs Assessments/Security Risk Assessments - KBCN1770

Where the author of a Security Needs Assessment [‘Security Risk Assessment’ in BIU] does not meet the BREEAM competency requirements, compliance can still be achieved where the report is reviewed and verified by a qualified SQSS [‘Competent Person’ in BIU], who confirms in writing that it is accurate, appropriate and in line with industry best practice. In these circumstances, the SQSS or ‘Competent Person’ is expected to verify and take ownership of the report and accept professional responsibility for its content.

View out – Calculating the glazing to wall ratio - KBCN1506

This should be calculated based on the glazed area of window, expressed as a percentage of the area of the external wall in which the window sits. Where the ceiling height of the room is unusually high, relative to the window height, the wall area can be calculated based on a standard ceiling height for the building type.

Volume Approach – Site visit requirements - KBCN1644

This guidance applies only to assessments for clients who have entered into a formal agreement with BRE to enter the Volume Approach. The aim of the Volume Approach is to assist clients with large numbers of assets, and their assessors, to conduct assessments in a robust manner, whilst also taking a practical view. From the clients’ assets that have entered the process, BRE will identify which assets may undertake a virtual site visit. The assets and their assessments cannot be new to the BREEAM In-Use process and must be identified and communicated to BRE prior to undertaking the site visits. The requirements of the virtual site visits are as follows: Gathering evidence for site assessments: In cases where BRE has identified an asset can undergo a virtual site visit, the assessor is not required to personally visit or gain access to the site, they can use the following methods:
  1. Appoint a suitable individual, for example a main contractor or asset manager, to undertake a formal site assessment on their behalf. The appointed individual would be expected to provide a robust account to the assessor of evidence in place of their own site assessment report. We would expect the report to contain photographs and/or virtual tour stills from the building and be signed off by both the appointed individual and assessor.
  2. For assessment issues relating to external spaces beyond the site, we will accept stills/images from Google Street View (or equivalent), provided it is demonstrated that such evidence is current.
  3. Desk-based evidence will be accepted where evidence demonstrates that the criteria are being met as far as possible without a site assessment.
It is important to note that where one of the above 3 options has been selected, the assessor is responsible for assessing the evidence and for the awarding of any credits. Timing of workshops, testing and other subsidiary evidence submissions: Given the widespread availability of remote communication technologies, it is generally possible to undertake the majority of activities relating to our assessment criteria without the need for face-to-face contact or site assessments. With respect to workshops, the key consideration is that they take place at a time when they have a meaningful impact and achieve the aim of the criteria. With respect to subsidiary, third party assessments such as ecological site inspections or audits, desktop surveys based on available information (e.g. planning surveys, agent’s reports, photographs, Google Earth), can be used as an alternative provided there is enough material for a confident recommendation and/or outcome to be achieved.    

Washer dryers - KBCN0699

Where a washer dryer is specified, the water consumption figure for the wash and dry cycle should be used. The drying cycle of a washer dryer is taken into account because it usually uses water during this drying process (e.g. for cooling during the drying cycle) and in some cases, this water usage can be significant.
18-Nov-2022 - Updated to apply to BREEAM In-Use Version 6

Washing machines and dishwashers – Water consumption data - KBCN1571

The water consumption data used to demonstrate compliance may be based on the lowest full wash cycle (i.e. not a pre-wash cycle, for example).

Waste streams – clarification - KBCN1526

Scope The focus of the criteria is on recyclable materials only. Any facilities / spaces for managing recyclable materials must be in addition to spaces / facilities for managing general waste. Definition “Waste streams are flows of specific waste, from its source through to recovery, recycling or disposal. Waste streams can be divided into two broad types: Source For BREEAM, a waste stream is a material / product with its own recycling process. This means each stream needs to be separated from other materials before it can be effectively processed into new materials / products. This separation can happen in the asset, or (in the case of co-mingled waste) after collection from the asset. Residential waste streams In most cases, this is defined by how it will be how be sorted and collected by municipal waste authorities. Where no local guidance exists, the list below may be used as a guide. Recyclable waste streams (answer option C in BREEAM USA In-Use Residential V6): Compostable / recyclable waste streams (answer option D in BREEAM USA In-Use Residential V6): Commercial waste streams Commercial assets will generate specialised waste streams specific to the asset's function. These are typically: In these cases, waste streams such as metals, plastics and paper / cardboard may be sub-divided into specialised waste streams where they meet the above. Example scenarios [accordion] [accordion_block title="Scope"] A vehicle repair workshop generates the following waste streams: The engine oils and general waste cannot be re-processed into other usable materials. Only 3 recyclable waste streams can be considered for BREEAM assessment. [/accordion_block] [accordion_block title="Residential"] The local authority collects co-mingled waste for the asset. This waste mixes together: This co-mingled waste can be counted as 3 waste streams. [/accordion_block] [accordion_block title="Commercial"] A supermarket consistently generates large quantities of cardboard packaging. This cardboard forms a significant portion of recycable waste generation. It is baled up and collected separately by a specialised waste contractor. In this case, cardboard waste can be considered a separate waste stream from paper. [/accordion_block] [/accordion]
18-Jan-2024 - Clarified list of residential waste streams (separated compostable waste streams and added relevant answer options).

Water consumption reporting – Link to Man 04 - KBCN1611

The link to meeting compliance with Man 04, outlined in Wat 13 Criterion 1 is incorrect and should be disregarded. Answer option D in Man 04 includes targets for Energy, Water and Waste. Whereas the intent of Wat 13 relates to targets for Water only. This will be updated in the next reissue of the technical manual.

Water strategy – Replacement and Schedule - KBCN1673

Replacement The intent is that there is a programme in place which identifies any planned refurbishments and confirms that, where relevant, the works will include upgrading high water-consuming fittings and appliances with low water-consuming equivalents. This does not require the systematic replacement of all fittings and appliances. However, it must also include a commitment to upgrading the efficiency of existing fittings and appliances when they reach the end of their service life. Schedule This may include specific fittings and appliances with low water consumption, or it can be based on a performance specification that these must meet, e.g. the flow rate or efficiency rating.