Benchmark energy performance value – clarification - KBCN1724
The benchmark energy performance value is a performance level which achieves the
median performance within a local energy performance standard's range of values.
Example
The asset is being benchmarked using the Energy Star Portfolio Manager.
Under this system, assets can receive a score from 1 to 100.
A score of 50 represents median performance, which equates to the benchmark energy performance value.
27-Mar-2025 - Published.
Clarification – percentage of end uses - KBCN1650
This percentage is measured by the energy consumption (kWh) of significant energy uses, not by the number of end uses.
Combined system for heating / cooling and domestic hot water - KBCN0329
It is permissible to have combined metering for a shared on-site or district system that combines heating / cooling, and domestic hot water generation.
In all cases, justification is provided in the QA report for the combined metering, and explains why it is not technically feasible to provide separate meters.
21-Sep-2022 Applicability of KBCN added to BIU V6. Amended to include district heating and cooling networks.
District heating / cooling / hot water – entering data into the Online Platform - KBCN1536
For assets which use district heating / cooling / hot water, information on the district systems are entered into Ene 09a and 09b.
In Ene 05 / 06 / 09, answer 'no' to first question
"Is space heating / cooling / hot water generated on-site?" then navigate to:
- Ene 09a to answer questions on district cooling.
- Ene 09b to answer questions on district heating and hot water.
A district heat network will also provide hot water, so information on the system which provides both is entered into Ene 09b.
The Online Platform differs from the manual structure, however it does not affect scoring in any way. All data entered contributes to the asset energy calculator.
Assets with on-site and off-site systems
Only answer questions on the system which provides the most signifcant heating or cooling to the asset. If an asset includes both on-site and off-site systems, choose the one which delivers the most energy annually.
Erratum – scope of issue - KBCN1498
Criterion 1 states:
"Where external lighting or car park lighting are not necessary from a safety perspective, the associated credits can be filtered out of the assessment."
What this means is:
- Where external lighting does not exist, filter out the relevant credits.
- Where car park lighting does not exist, filter out the relevant credits.
- Whether or not the lighting exists for safety reasons has no effect on credit filtering.
The inclusion of the word 'safety' in this criteria is misleading and will be removed in future versions.
28-Feb-2024 - Wording clarified.
Erratum – up to V6 – methodology – no default energy assumptions - KBCN1630
The scope of the issue applies only to systems with
significant energy use.
The methodology section states that the online platform will calculate
default values, and use this to indicate which systems are in scope.
This is incorrect, as default values are
not automatically calculated.
The energy use of each system will need to be manually estimated. This can be done based on:
- Typical benchmark values, and / or,
- Estimates based on the capacity of equipment, and annual equivalent full load hours of use.
Erratum – V6.0.0 – cooling efficiency parameter – EER / SEER - KBCN1560
In the asset energy calculator guidance, the parameter given for cooling efficiency is 'SEER' (Seasonal Energy Efficiency Ratio).
This is incorrect and should say '
EER'.

This affects the following tables:
|
International |
USA |
| Commercial V6.0.0 |
Table 19 |
Table 18 |
| Residential V6.0.0 |
Table 16 |
Table 16 |
This will be updated in the next manual re-issue.
Installed controls – ‘Asset does not have both heating and cooling’ - KBCN1678
In the technical manual, the intent is that Q1, Q2 and Q3 allow the credits to be filtered where the asset has 'neither heating nor cooling', in line with the assessment tool.
This will be updated in the next reissue of the technical manual.
Interlock controls – clarification - KBCN1491
An interlock is a control that is wired so that when there is no demand for heating / cooling in a space, the heating / cooling generator and the associated pumps are switched off. Use of thermostatic radiator valves (TRVs) alone does not provide interlock.
Partial interlock means that the cooling and heating interlock controls are separate. However, the control function may be set up to minimise the possibility of simultaneous heating and cooling.
Total interlock means the controls are wired so that simultaneous heating and cooling is not possible. Where there are separate local heating or cooling units present, these will also need to be wired into the control system for total interlock to avoid the possibility of simultaneous heating and cooling.
Lift or escalator efficiency – Manufacturer’s product data - KBCN1870
Where manufacturer’s product data showing the rated efficiency class is available, this can be used as evidence of meeting the required energy efficiency class stated in the technical manual.
Additionally, the following supporting evidence must be provided:
- Evidence to demonstrate that the installed lift or escalator is the same as the one in the product literature
- Confirmation that the lift or escalator has not undergone any modification since it was installed
Local energy performance asset rating – Validity period - KBCN1913
If an energy performance asset rating is currently valid at the time of measurement, it is valid for this issue.
It does not need to be obtained specifically during the current assessment cycle. For example, if an asset obtained a compliant rating in 2020 which is valid until 2030, this can be used in a current measurement in 2027.
24-Sep-2026 - KBCN reinstated
Local energy performance asset rating – Whole asset not covered - KBCN1912
The energy performance asset rating does not need to cover the whole asset. However, it must cover all occupied areas of the building.
24-Sep-2026 - KBCN reinstated
Multiple ratings in a single assessment - KBCN1725
Sometimes the boundaries for energy performance ratings for meeting building regulations are split in a different way to the BREEAM assessment boundary.
If the BREEAM assessment boundary covers multiple energy ratings, for this issue only enter data on the rating which covers the largest NIA (Net Internal Area).
27-Mar-2025 - Published.
Night-time operation – requirement for controls - KBCN1048
Projects
or areas of an asset which operate at night-time can adapt or omit the requirement to provide controls or presence detection to align with the building’s hours of operation.
This could, for example, include service yards or car parks.
The aim of this Issue is to reduce the energy use for external lighting and should not interfere with the building’s operation.
02 Oct 2024 - Updated to clarify the scope of the this guidance and applied to NC V6 and BIU.
On-site LZC – whole site shared connection - KBCN1424
To be recognised in BREEAM, the on-site Low and Zero Carbon (LZC) technology must have a direct physical connection to the assessed asset.
OR
Where the LZC technology is;
- Located on the same site,
- Is owned and managed by the same organization as the assessed building, and
- Where it is impractical to physically connect the assessed building to the system,
It is acceptable to allocate the renewable energy generated proportionally as a calculation of the asset's predicted energy consumption compared to the total energy consumption of the whole site.
To allocate renewable electricity by proportional consumption:
- Obtain the total annual renewable electricity generated on-site.
- Exclude all renewable electricity which has been exported to the grid.
- Determine the respective electricity consumption of all assets on the whole site (predicted for new builds and measured for existing assets).
Where consumption data is missing, renewable electricity must not be allocated to the assessed asset. In this case, it is assumed that all electricity consumed is sourced from the grid.
17-Jan-2024 - Applicability BIU V6 Ene 13 removed, as this approach is not applicable to assessing the area of PV fitted.
21-Dec-2022 - Applicability to In-Use V6 confirmed.
Presence detection – illuminated signs - KBCN1671
The requirements for presence detection do not apply to illuminated signs.
In BIU V6, presence detection requirements are included as part of automatic energy saving controls. All other requirements in this criteria must still be met.
Systems serving <10% overall floor area - other affected issues - KBCN1542
The methodology for Ene 01 states:
"Heating / cooling systems can be excluded from the calculation where the heated or cooled area equates to less than 10% of overall floor area."
Systems which heat or cool < 10% overall floor area
are not assessed in:
- Ene 01 Building services.
- Ene 05 Cooling.
- Ene 06 Heating.
Ene 01, 05 and 06 all feed into the asset energy calculator and so their inputs must be consistent. All other issues relating to these excluded systems are still assessed such as:
- Ene 11 Installed controls.
- Ene 15 and 16 Monitoring energy issues.
- Pol 03 Local air quality.
- Pol 04 Global warming potential of refrigerants.