In-Use / BIU 2015 / BIU 2015 Part 2 /

04 - Water

Information correct as of 27thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Operational energy and water use during Covid-19 lockdown - KBCN1425

As we continue to adapt to and assess the impacts of the COVID-19 pandemic, the BREEAM team is seeking to ensure that the data underpinning BREEAM in Use certification accurately reflect typical operational performance. We appreciate that the full or partial lockdown conditions related to the pandemic may have had a significant impact on the performance of the asset particularly the operational energy and water consumption. We trust our assessors to use their professional judgement to determine the extent that operational energy and water consumption has been impacted by the COVID-19 restrictions. They must ensure that submitted consumption data is representative of consumption under normal conditions. Clients should work with their assessors if they are unsure how they should proceed. Assets are likely to have been affected by many different local lockdown scenarios so one approach to reporting consumption data is unlikely to apply to all situations. For example, normal consumption data is likely to be sufficient for assets that have only had a minor changes to their operations (e.g. two weeks), if the rest of the 12 month period has been unaffected. For assets that been more significantly affected (e.g. several months of reduced occupancy), it is likely that energy and water consumption data will need to be taken from a period of time before local lockdown restrictions came into force. In this scenario, the following approach can be used:

The consumption reported must cover the 12 months prior to the restrictions coming into force.  The reported consumption would need to be validated against the year prior to the reporting period to provide assurance to the Assessor that it was in line with typical operations.  Additional evidence and verification will be required for submission. The following sections should help clarify how this should work:

Normal BREEAM requirements

Consumption Reporting:

Evidence requirements:

New requirements for this KBCN

Consumption Reporting:

Evidence requirements:

Example for a building submitting for certification in October 2020 subject to lockdown from March 2020:

Normal reporting period October 2019 – September 2020

Adjusted reporting period in line with this KBCN March 2019 – February 2020 Validation period: March 2018 – February 2019

This KBCN will remain in place but will be under review as we continue to monitor the impacts of COVID-19 and amend requirements as circumstances change.  We will keep assessor informed of BREEAM In-Use users and assessors via further service announcements and other communication channels.

Validity of consumption data - KBCN1304

In order to maintain the reliability of data entered into the BREEAM In-Use Online Platform, any consumption-related data submitted must have a reporting period start date which is no more than one year prior to the start of the assessment (creation of a measurement). For example, if the assessment was started on the 3rd of April 2018, the reporting period start date cannot be prior to 3rd of April 2017. A more recent period can always be entered, as long as the assessor can verify that the data is correct for the period entered.