New Construction / International / 2016 / 04 - Transport /
TRA 02 - Proximity to amenities
Information correct as of 8thNovember 2026. Please see kb.breeam.com for the latest compliance information.
Amenities – Postal facility - KBCN0114
The wording 'postal facility' is intended to allow greater flexibility than previously given, to recognise the changing nature of postal services in the UK and internationally.
For example, in the UK it would now be considered compliant for a building operator to have an in-house postal delivery and collection service provided by the Royal Mail, where this is available to all building users. Naturally, post boxes and post offices are also still compliant.
Amenities – Access to cash - KBCN0359
Refers to the availability and convenience of reaching an Automated Teller Machine (ATM) to access cash. Building users should have access to cash at all relevant times of day. This is interpreted as availability during the local community's typical active hours.
For non-residential assessments:
- Relevant times refer to the building’s operating hours or the typical active hours in the local area.
- An ATM inside a building is acceptable as long as its operating hours are convenient for building users.
- This should not require a prior purchase of goods and should provide access to other services, such as checking account balances.
For residential assessments:
- 24‑hour access is preferred; however, access during typical active hours (e.g., 07:00–22:00) is acceptable when 24‑hour provision is not feasible or not available locally.
19-Feb-2026-clarified residential requirements to align with non-domestic schemes. With cash being used far less freque
Amenities – Assessed building is one of the listed amenities - KBCN0264
Where the assessed building is itself included in the list of amenities, that particular amenity criterion can be deemed to be met, e.g. a supermarket development itself meets the proximity to food outlet required for a Retail type building.
Amenities – Community facility – Collaborative work areas (shared workspace) - KBCN1918
For appropriate building types, a collaborative work area can qualify as a
community facility where it is demonstrated that:
- It provides a relevant amenity for users of the assessed building.
- It is fit for purpose.
- It is suitably sized for the number of building users (accounting for any public access, where relevant).
- It is available to building users at appropriate times.
Amenities – Pharmacy within a hospital or health centre - KBCN0321
To meet the requirements of 'Over the counter services associated with a pharmacy', a dispensary within a health centre or hospital can be considered as meeting the intent, provided it is publicly accessible and also offers the type of over-the-counter services associated with a stand-alone pharmacy, such as non-prescription medication and health products.
Note: This is a change to the approach outlined in the previous KBCN wording, therefore, for assessments registered before this update, where it can be demonstrated that the the assessor has advised the project team based on the previous wording, this can be accepted:
Superseded guidance:
A publicly accessible pharmacy would typically be required in order to constitute a suitable amenity. If it can be confirmed that an internal pharmacy (in Northern Ireland this may also include an onsite controlled medical dispensary) will provide prescribed medicines for building users, this is acceptable.
18 June 2025 - Title updated and wording amended to clarify the intent. Applied to NC V6 standards.
Amenities – Sandwich van as a food outlet - KBCN0557
A food truck/ mobile catering service would not be sufficient to meet the criteria for this issue.
The aim of this Issue is to assess the location of the built asset relative to amenities.
Amenities – Vending machine as a food outlet - KBCN0653
A vending machine can be considered as a food outlet if a range of items, as can be reasonably expected, are for sale to meet the needs of the building users and it is confirmed to be a permanent fixture.
Safe pedestrian routes – Definition, measurement and verification - KBCN0238
Definition
Safe pedestrian routes include sidewalks and safe crossing points, which may be controlled or, for example, be identified by tactile paving, a crossing island or a dropped curb. An element of judgement may be required, in which case justification should be provided.
Measurement
Distances could be measured, for example, along a sidewalk, across a road at a safe crossing point and along the sidewalk on the other side. The distance should not be measured diagonally across a road, following the most direct route.
Verification
The assessor’s site inspection is an important aspect of the assessment and may help to confirm that all relevant information is current and can include photographs of any key areas. This can also help to identify safe crossing points or hazards which may not be apparent from a desktop study. However, web-based evidence may also be used where the assessor is satisfied that it is robust and demonstrates that it is up to date.
Where web-based navigation maps (e.g. Google Maps/Street View) are used as supporting evidence, this must include:
• Dated and marked-up site plan or a web-based navigation map viewer highlighting:
• Current location and type of transport nodes and local amenities.
• Current route and distance from the building via a safe pedestrian route.
• Plan or map scale.
When using web-based evidence for post-construction stage, the assessor must, additionally, provide verification that the information provided for the nodes/amenities is still accurate and up to date.
29 Aug 2025 - Approach to web-based map data at post-construction stage updated and related wording amended accordingly
07 Mar 2024 - No changes have been made. This appears as 'updated' due to an administrative error.
11 Jan 2024 - Wording re-structured for clarity
19 Dec 2023 - Applicability to BIU V6 confirmed
Table 32 in the manual SD233 issue 2.0 - KBCN1154
For the purpose of assessing this BREEAM issue, the table to refer to is the first one, i.e. Table 32.
The two tables that follow are a typo and should not be considered.
Technical manual to be updated accordingly in next reissue.
Information correct as of 8thNovember 2026. Please see kb.breeam.com for the latest compliance information.