In-Use / BIU USA 2016 / BIU USA 2016 Part 1 / 03 - Transport /

TRA 01 - Cyclist facilities

Information correct as of 24thNovember 2026. Please see kb.breeam.com for the latest compliance information.

Cycle spaces – Folding bicycles and scooters - KBCN00024

The provision of cycle storage that is only suitable for folding bicycles or scooters is not compliant. Providing reduced storage space for folding bicycles or scooters in place of compliant cycle storage may limit future travel options.
14 03 2018 Wording clarified and reference to scooters included.

Cyclists’ facilities – to match additional bicycle spaces - KBCN00093

The minimum number of showers/lockers/changing facilities required for BREEAM compliance is determined by the minimum number of compliant bicycle spaces required, not by how many total compliant bicycle spaces have been provided. Where more than the minimum number of compliant cycle spaces has been provided, there is no requirement to provide more than the minimum number of showers/lockers/changing facilities.
01 Feb 2022 - Applicability to BIU USA Commercial V6 confirmed

Cyclists’ facilities – Within toilet facilities - KBCN00050

Showers compliant with the criteria for cyclist facilities should not obstruct the use of general and disabled toilets. They are not compliant unless it can be unequivocally demonstrated that these cyclist facilities are provided in addition to toilet facilities provided for persons with disabilities and general building users.  To ensure that there is no conflict between the use of general or disabled restrooms and the use of cyclist facilities.  

Cyclists’ facilities – Within toilet facilities - KBCN00050

To comply with the criteria for cyclist facilities, showers should not obstruct the use of other facilities. Where a shower is located in a room with a WC, this cannot be considered compliant, unless it can be unequivocally demonstrated that the WC is provided over-and-above the requirements of relevant standards or regulations for general and disabled WCs.

To ensure that there is no conflict between the use of general or disabled WCs and the use of cyclist facilities.
25.10.18 KBCN reworded to improve clarity.
 

Facilities provision for public bicycle sharing systems - KBCN0276

Where a public bicycle sharing system is being used to account for up to 50% of cycle spaces provided, the total number of cycle spaces, including those provided by the bicycle sharing system, should be the basis on which the compliant cyclist facilities are provided. This is because people using public cycle spaces will still need the use of cyclist facilities such as showers and lockers.
13.08.2018 KBCN applied to the BREEAM In-Use scheme.

Information correct as of 24thNovember 2026. Please see kb.breeam.com for the latest compliance information.