Approved Equivalent Roles List (AERL) - KBCN1809
BREEAM International standards are unique because of their flexibility.
For International projects, Assessors can submit roles to substitute those described in the Technical Manuals. Provided that such roles are equivalent to the BREEAM specified roles, BRE Global will approve them for use in a particular country or region.
The
Approved Equivalent Roles List is a record of all roles that BRE Global has approved to date. The list is periodically updated to reflect recent approvals or withdrawals.
Using existing approved roles
Where you are using an approved role, and not the role described in the criteria in the scheme Technical Manuals, a copy of the AERL should be included as part of your evidence submission for QA.
AERL versions
The version of the AERL that is current at the time of registration is the one that is used for assessment. Newer versions released after this can also be used, however older versions before the registration date cannot be used.
For example: if the version current at registration was v3.0, then v3.0 (or any later versions) can be used, but v2.0 (or any earlier versions) cannot be used.
Proposing new roles
New roles cannot be proposed if they are not of equal competency to the BREEAM requirements. Only roles which are equivalent or more rigorous than the BREEAM default roles are considered.
If you wish to propose a new role which you think is equivalent in your country or region:
- Check what the role needs to cover by referring to the roles described in the scheme Technical Manual definition.
- Complete BF2599 BREEAM Approved Equivalent Roles Application Form and send this to our Technical Team via the Query Webform, adding AERL into the subject field.
The information provided to us within this form must include:
- the names of the proposed role(s)
- confirmation of the scheme and issues the role should apply to
- confirmation of the roles / competent persons you are referring to in the manual
- a detailed explanation of how this work is conducted in your market and how it meets the same level of competency as the BREEAM requirements
- documentation to support your explanation which is clearly marked for our ease of reference. If the documentation is not in English, translations of the relevant sections must be provided.
We will need a few weeks to review the information (please check with us for time scales). If there is missing information, or the information is not clearly referenced, this might take longer.
If successful, we will send you a revised copy of the AERL which includes the new role, and will update this for future versions of the AERL.
Assessing multiple residential buildings - KBCN1687
BREEAM In-Use has been developed as an environmental assessment method to assess existing assets. Typically, an asset consists of a single building or part of a single building. However, BREEAM In-Use provides an exception where certain criteria have been met, and this is set out in the relevant Technical Manual under the Eligibility Criterion 5 and reproduced below with clarifications noted in Italics.
The requirements to assess multiple buildings as a single asset
Criterion 5 states: An asset cannot normally include more than one building. The only exception is where several buildings meet the following criteria:
a) All buildings must be located on the same site. The site boundary must be drawn where responsibility for management or ownership of the site changes.
For multifamily assets, this means all structures within the property boundary.
For individual homes, e.g. single family, townhouses, this means the properties on which the homes are located are contiguous.
b) All buildings must have the same building function, similar performance, and be of similar design and age.
Multifamily projects, such as garden style apartments, can still be grouped together under these criteria, even if they include different unit types.
c) Building management and maintenance policies, procedures and approach must be the same across all the buildings that make up the asset to ensure consistent implementation.
Where maintenance policies, procedures, and approaches are the tenant’s responsibility through the leasing arrangements, these can vary, but overall building management needs to be the same for all properties
d) Evidence must be collated from each building that is included in the asset and where performance against the BREEAM requirements varies, the final score will be determined by the space with the lowest level of performance.
The whole data set for all buildings in the assessment must be gathered and provided to the Assessor by the Client.
Demonstrating compliance for certification
- The Client will be required to demonstrate how each criterion has been met and provide evidence to support the approach.
- The Assessor must then confirm the criteria have been met through their evidence review and on-site verification.
- Site level assessments should use a floor-area-weighted average method to confirm compliance.
- For other residential assessments involving multiple buildings, representative sampling is permitted to confirm compliance. Assessors are required to confirm that the worst-case performance was applied by the Client. Assessors are required to create and document a robust representative sampling method and demonstrate that they conducted their assessment in accordance with their methodology.
- Where the Assessor is unsure how to interpret or apply the criteria, they should contact the Technical Team for clarification using the BREEAM Projects webform before submission for certification. Where relevant, a copy of the technical clarification response should be submitted as supporting evidence.
Considerations before undertaking this approach
- The rating will reflect the worst performance of all the buildings included within the assessment.
This will limit the visibility of buildings within the grouping that may have better performance and opportunities at individual assets to improve performance. Assessing the buildings separately allows for the granularity of the assessment to provide owners with more detailed information on how improvement plans can be rolled out and the value to be gained from driving performance.
- Should the buildings be sold individually, the certification status does not transfer with the individual buildings.
The building(s) sold would need to undergo the full certification process, including benchmarking and the on-site visit with a licensed Assessor, to be considered certified and claimed by the new ownership.
- The certificate may be updated through a mid-cycle process to remove the assessed area of the building(s) sold.
This could increase the score if the building sold represented the worst-case performance. If the building removed from the certification formed the basis of the score as the 'worst-performing', the Assessor would need to complete another site visit for the mid-cycle to ensure that the new data representing the worst performance is accurate.
Asset classification – co-living developments - KBCN1568
This guidance is intended as a general reference only. Each co-living development will include a different combination of residential accommodation and managed communal spaces. Assessors must apply professional judgement to determine the most appropriate asset classification.
Typical characteristics of co-living developments
Developments within these sectors typically include the following characteristics:
- Institutional ownership and professional management
Purpose built for rental as the primary function, rather than individual sale, and owned by a single entity with professional property management in place.
- Self-contained, functional units
Residential apartments with private kitchens and bathrooms.
- Managed communal facilities
Extensive shared amenities, such as fitness suites, co-working areas, communal terraces, and secure bicycle storage.
- Flexible, long-term tenancy
Tenancy agreements are generally designed for longer term occupation, typically six to twelve months.
Classification guidance
International assets:
The following classifications are recommended:
| Assessment Type |
Recommended Classification |
| International New Construction, International Refurbishment and Fit-Out (will become Refurbishment and Fit-out from V7 onwards) |
Residential institutions- long term Stay* |
| BREEAM In Use (BIU) |
Residential |
*Assessors should also consider how the asset is classified under relevant local building regulations to support the interpretation of Residential Institution.
UK NC assets (KBCN1225, provides additional clarification):
Using Building Regulations classifications as a guide
- Part L, Volume 1 (Dwellings): Classified as Residential, covered under UKNCR (formerly known as HQM).
- Part L, Volume 2 (Buildings other than dwellings): Classified as a Residential Institution, covered under UK New Construction.
17-Jun-2026 - Guidance revised and updated for clarity
Eligibility criteria – BIU International Residential V6 - KBCN1668
The Eligibility Criteria for BIU V6 Residential have been updated, and the guidance below supersedes Criterion 2 in the V6.0 technical manual:
Criterion 2)
a) Submission for certification must be a minimum of 12 months from completion of the dwellings.
AND
b) For a Part 2 assessment, 12 months’ utility consumption data must be available for a minimum of 80% of the dwellings.
AND
c) The asset must be intended to be a primary residence of the occupants.
GN26 Representative sampling methodology for assessor site inspections - KBCN1914
Latest version: v0.0, September 2026
Guidance Note 26 (GN26) provides information to BREEAM In-Use assessors on how to use representative sampling during site inspections. It aims to help assessors carry out a proportionate, risk-based inspection strategy without needing to inspect every building, apartment, or element. This guidance may be used at the assessor's discretion to support decisions regarding sampling during site inspections for BREEAM In-Use.
Download Guidance Note 26 (licensed assessors only)
View all Guidance Notes on BREEAM Projects (licensed assessors only)
24-Sep-2026 - KBCN reinstated
Recognising future performance - KBCN1538
BREEAM In-Use recognises an asset's operational performance
at the time of certification.
Compliance
cannot be based on commitments to improve the performance of an asset in the future.
Where changes to an asset are made during a 3-year certification cycle:
- BREEAM In-Use V6 allows the asset's mid-cycle performance to be updated and reflected in an updated certificate.
- Legacy versions of BREEAM In-Use recognise updated performance via re-certification.
Residential eligibility criteria – clarification on occupancy levels [superseded] - KBCN1523
01 Nov 2014 This guidance is now superseded. Please refer to KBCN1668
Single and Multiple Certification options - KBCN1430
BIU Residential provides flexible options to allow as many residential buildings as possible to be rated and receive a certificate. These include:
Apartments
- Multiple certificates, one for each individual apartment unit
- A single certificate for all the apartments only
- A single certificate for all the apartments and the common area
Houses
- Multiple certificates, one for each individual house unit
- A single certificate for all the houses
Benefits of the different certification options
Multiple certificates – These show the performance of each residential unit. This can show the difference in scoring and rating between units, which could be used for sales purposes or as a way of targeting specific units for improvements. When opting for multiple certificates, the rating of the best performing units will not be limited by the performance in other units.
Evidence must be collated from each building that is included in the assessment and where performance against the BREEAM requirements varies, the final score will be determined by the apartment or home with the lowest level of performance.
Single Certificates – These show the performance of the apartment(s) or house(s) as a whole. While performance has to be documented for each dwelling, BREEAM Projects includes features which help streamline this process.
Which certification route is right for my Asset?
When assessing just the Asset Performance in BREEAM In-Use Residential v6, the choice of certification option is up to the client. However, if Management Performance is included in the scope of assessment then the differing data requirements will determine which certification option the project needs to follow. These differing data requirements are driven by the energy consumption data available.
The flow diagram below can be used as a guide to determine the appropriate certification route for your project, given the energy consumption data available.

The scope of the energy data available will typically be more variable for an apartment building compared to houses. Houses tend to be individually metered, and therefore certification options are more open to client choice.
Note: Any asset without compliant consumption data will not be able to achieve all of the credits within Management Performance (e.g. the Operational Energy Calculator and Water)
If further assistance is required, please contact BRE at
BREEAMInUse@bregroup.com
24 Apr 2024 - Paragraph headed 'Benefits of the different certification options' updated for clarity and KBCN applied to BREEAM In-Use USA Residential
20 July 2021 Amended for clarification and flow diagram updated
Volume Approach – Site visit requirements - KBCN1644
This guidance applies only to assessments for clients who have entered into a formal agreement with BRE to enter the Volume Approach.
The aim of the Volume Approach is to assist clients with large numbers of assets, and their assessors, to conduct assessments in a robust manner, whilst also taking a practical view. From the clients’ assets that have entered the process, BRE will identify which assets may undertake a virtual site visit.
The assets and their assessments cannot be new to the BREEAM In-Use process and must be identified and communicated to BRE prior to undertaking the site visits.
The requirements of the virtual site visits are as follows:
Gathering evidence for site assessments:
In cases where BRE has identified an asset can undergo a virtual site visit, the assessor is not required to personally visit or gain access to the site, they can use the following methods:
- Appoint a suitable individual, for example a main contractor or asset manager, to undertake a formal site assessment on their behalf. The appointed individual would be expected to provide a robust account to the assessor of evidence in place of their own site assessment report. We would expect the report to contain photographs and/or virtual tour stills from the building and be signed off by both the appointed individual and assessor.
- For assessment issues relating to external spaces beyond the site, we will accept stills/images from Google Street View (or equivalent), provided it is demonstrated that such evidence is current.
- Desk-based evidence will be accepted where evidence demonstrates that the criteria are being met as far as possible without a site assessment.
It is important to note that where one of the above 3 options has been selected, the assessor is responsible for assessing the evidence and for the awarding of any credits.
Timing of workshops, testing and other subsidiary evidence submissions:
Given the widespread availability of remote communication technologies, it is generally possible to undertake the majority of activities relating to our assessment criteria without the need for face-to-face contact or site assessments. With respect to workshops, the key consideration is that they take place at a time when they have a meaningful impact and achieve the aim of the criteria.
With respect to subsidiary, third party assessments such as ecological site inspections or audits, desktop surveys based on available information (e.g. planning surveys, agent’s reports, photographs, Google Earth), can be used as an alternative provided there is enough material for a confident recommendation and/or outcome to be achieved.