Domestic Refurbishment / 2014 / 03 - Energy /

ENE 05 - Energy Labelled White Goods

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Communal laundry facilities - KBCN0776

Credits can be awarded to all dwellings that have access to communal laundry facilities, provided the appliances meet the EU energy labelling requirements in Ene 05.

Energy Savings Trust website criteria - KBCN0140

In previous versions of BREEAM New Construction 2011, compliance with the Energy Saving Trust (EST) criteria for domestic scale appliances was required  for credit Ene 08 Energy Efficient Equipment. As this information is no longer readily available from EST, compliance can be demonstrated where domestic scale equipment meets the requirements for the EU Energy Efficiency Labelling Scheme as outlined in the latest BREEAM New Construction 2011 manual.

New EU energy labels - KBCN1445

Background

In recent years, the market for domestic-scale appliances has seen excellent progress, with increasingly energy-efficient products becoming widely available. Consequently, the A-rated category was extended over time to include A+, A++, and A+++ ratings. Meanwhile, the lower ratings, such as E, F and G have become increasingly rare. It was clear that an adjustment to a new, simpler set of ratings was required.

Statutory Changes

From 1st March 2021, the European Commission requires new, updated energy labels of A to G for dishwashers, washing machines, fridges and electronic displays. Lamps will require the new ratings from 1st September 2021 and requirements for re-labelling tumble dryers are yet to be confirmed. This means:

Changes for BREEAM and HQM

As a result of the introduction of the new EU ratings and in order to maintain the original intent of the BREEAM criteria, the approach for our schemes has had to change. It is not possible to establish direct equivalence between the old and new energy labels, therefore the updated approach will be to recognise the best-performing 25% of each appliance type, based on a comprehensive market sample. The table below shows how this translates into the new EU Energy Labels for different appliance types.

Appliance type

Rating required

Fridges, fridge-freezers, freezers
E
Washing machines
B
Dishwashers
D
Washer-dryers
D - D
  This approach will ensure that BREEAM continues to drive the energy efficiency of appliances by demonstrating a meaningful reduction in energy consumption. Note that these new requirements will be reviewed from time to time and may be subject to change. Where assessments have already specified (and can procure) products bearing the old labels, it is acceptable to follow the previous criteria. However, where products bear the new label and for all assessments registered after 31/05/2021, the new criteria must be met.  
17 Apr 2023 - Applicability to NC2013 confirmed.
21 Mar 2022 - Confirmation added that washer-dryers require a D rating for both cycles
23 Nov 2021 - Reference to 'freezers' added to appliance types
12 May 2021 - Guidance updated and applicability to HQM One and BREEAM NOR confirmed

Wine coolers - KBCN0374

Wine coolers fall outside of the scope of this issue therefore do not need to meet the criteria for fridges. HQM - this means they do not need to be included in HQM's Energy Forecast and Cost bolt-on reporting tool.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.