Measuring ecological change – Using Defra Metric 3.0, 3.1, 4.0 and the Statutory Biodiversity Metric - KBCN1476
Defra Metric 3.0, 3.1 and 4.0 have been mapped to the BREEAM Change in Ecological Value Calculator and can be used in assessments for BREEAM UK New Construction 2018, BREEAM Infrastructure Version 6 (formerly CEEQUAL Version 6), and Home Quality Mark ONE.
Please see the table below for the applicable benchmarks where Defra Metric 3.0, 3.1 or 4.0 is used. The benchmarks from the Defra Metric are taken from the lowest score from the three metrics (Habitat, Hedgerow, River).
If a metric is not present, e.g. there is no river on the site, the score of 0 for that metric must be ignored when taking the lowest score.
| Metric result |
Credits awarded |
| BREEAM (GN36) / Defra Metric 2.0 |
Defra Metric (3.0, 3.1, 4.0)
and the Statutory Biodiversity Metric |
BREEAM UK NC 2018 |
HQM ONE |
BREEAM Infrastructure V6 |
| Less than 75% |
Less than -25% |
0 |
0 |
0 |
| Between 75% and 94% |
Between -24% and -6% |
1 |
2 |
10 |
| Between 95% and 104% |
Between -5% and 4% |
2 |
4 |
20 |
| Between 105% and 109% |
Between 5% and 9% |
3 |
6 |
30 |
| 110% and above |
10% and above |
3 + 1 exemplary level credit |
8 |
40 |
The above approach can be used to determine the percentage score that describes ecological change in Guidance Note 36 (Table 9: Reward Scale), if the following is also met:
- A Suitably Qualified Ecologist confirms that they have used the Defra Metric tool to measure ecological change in line with up to date good practice regarding the Mitigation Hierarchy and Biodiversity Net-Gain including CIEEM, CIRIA & IEMA, 2019, Biodiversity Net Gain. Good practice principles for development: A practical guide (https://cieem.net/i-am/current-projects/biodiversity-net-gain/)
- The Methodology sections of the relevant ecology assessment issues are followed
- All other relevant criteria are met
- One calculation tool is used consistently throughout the development to determine the change in ecological value. i.e. A mixture of outputs from the BREEAM Ecological Change tool and Defra Metric cannot be combined
Alternatively, the BREEAM Change in Ecological Value calculator tool will continue to be accepted until stated otherwise.
03-Mar-2022 - Updated to clarify how Defra Metric 3.0 can be applied to current schemes
27-May-2022 - Updated to Defra Metric 3.1
21-Sep-2022 - Clarification on the figure to use from Defra Metric 3.0 or 3.1
14-Oct-2022 - Updated following rebrand of CEEQUAL to BREEAM Infrastructure
16-Feb-2023 - Added rules and clarification from KBCN1407.
01-Jun-2023 - Addition of DEFRA Metric 4.0
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
26-Nov-2026 - Fixed applicability (applicable to BREEAM Infrastructure V6)
Minimum standards – Scope out - KBCN1681
Any BREEAM Infrastructure criteria agreed for ‘scope out’ within an assessment are removed from the assessment in their entirety. This applies to criteria marked as a ‘minimum standard’. When seeking to achieve an Outstanding rating, where one or more of the ‘minimum standard’ criteria are scoped out, these no longer contribute to achieving an Outstanding rating.
For example, if criterion 7.2.2 is agreed for ‘scope out’, the minimum standard will be based on achieving a score greater than 90% and meeting criteria 2.1.2, 2.1.3, 4.4.1 and 7.4.2.
Norwegian Approved Standards List (ASL) – BREEAM Infrastructure - KBCN1774
The Approved Standards List for Norway is a record of all local codes and standards that BRE Global has approved to date for the BREEAM Infrastructure scheme. The list is periodically updated to reflect recent approvals or withdrawals.
Local best practice codes and standards can be submitted to BRE Global to substitute for the standards described in the criteria in the scheme Technical Manuals. Provided that such standards are equivalent to the BREEAM specified standards.
Please see the ASL Norway document within the BREEAM Infrastructure documents folder on BREEAM Projects, which contains the Norwegian national best practice standards and/or tool reference and the relevant BREEAM Infrastructure criteria:
BREEAM Projects - Other BREEAM Infrastructure Documents
The standards listed within this document are approved by BRE and are considered a suitable counterpart to the UK/International best practice standard, tool or scheme listed in the BREEAM Infrastructure V6 International Projects or Term Contracts technical manual. The Norwegian standards, tools and schemes listed can be evidenced, referenced or used in place of those identified.
Norwegian ASL version
The version of the ASL that is current at the time of registration is the one that is used for assessment. Newer versions released after this can also be used, however older versions before the registration date cannot be used.
For example: if the version current at registration was v3.0, then v4.0 (or any later versions) can be used, but v2.0 (or any earlier versions) cannot be used.
Standard versions and proposing new standards
Where a standard has been updated, it is not automatically added to the ASL template as the scope of the standard may have changed. If you wish to propose a new standard which you think is more relevant, or if an existing local standard has been replaced or updated, please contact BREEAM Infrastructure (
breeaminfrastructure@bregroup.com). This information will then be shared with Grønn Byggallianse (Norwegian Green Building Council), the NSO for Norway, and the standard reviewed for applicability.
PAS 2080:2023 – BREEAM Infrastructure - KBCN1628
An updated version of PAS 2080 was released in April 2023 (PAS 2080:2023), superseding the previous version (PAS 2080:2016).
The latest version of PAS 2080 may be used in BREEAM Infrastructure assessments in place of the previous version. The equivalent, relevant clauses are given in the table below.
| PAS 2080:2016 (original) |
PAS 2080:2023 (updated) |
| Clause 7 – Quantification of GHG emissions |
Clause 7 – Whole life carbon assessment principles to support decision-making |
| Clause 8 – Target setting, baseline setting and monitoring |
Clause 8 – Target setting and baselines |
| Clause 9 – Reporting |
Clause 9 – Monitoring and reporting |
| Clause 10 – Continual improvement |
Clause 11 – Continual improvement |
| Clause 12 – Claims of conformity |
Clause 12 – Claims of conformity |
The references to specific clause numbers for claims of conformity remain unchanged (part of Clause 12 in PAS 2080).
The latest version of PAS 2080:2023 is available to download from BSI:
https://knowledge.bsigroup.com/products/carbon-management-in-buildings-and-infrastructure
An updated guidance document for PAS 2080:2023 is available from ICE:
https://www.ice.org.uk/engineering-resources/briefing-sheets/guidance-document-pas2080
Summary of changes – BREEAM Infrastructure Term Contracts Version 6 - KBCN1546
BREEAM Infrastructure Term Contracts Version 6 was released on 12 October 2022. It replaces the previous scheme for the assessment of term contracts, CEEQUAL Term Contracts Version 5.2.
The update aligns the scheme with BREEAM Infrastructure Projects Version 6 (formerly CEEQUAL Projects Version 6), bringing the changes introduced to project assessments in 2019:
- New or updated technical requirements for:
- Carbon management – new issue on managing and reducing whole life carbon emissions using the approach described in PAS 2080.
- Circular economy – new requirements on considering and implementing alternative procurement options or circular economy business models.
- Resilience – new requirements added around risk assessment and mitigation.
- Biodiversity – new metric-based approach.
- Ethical labour – new issue on ‘Staff and supply chain social governance’.
- Protection of vulnerable road users – new criteria to improve safety and reduce risks for vulnerable road users.
- New ‘Outstanding’ rating level and introduction of minimum standards (for the ‘Outstanding’ rating level). The rating levels for ‘Pass’ and ‘Good’ have also been increased to align with other BREEAM schemes.
- Introduction of innovation category and credits – it is now possible to apply for approved innovation credits using the same process available in other BREEAM schemes.
- Format and terminology are now more aligned with other BREEAM schemes.
The latest version of Term Contracts also incorporates additional improvements to the operation of the scheme:
- Single manual for assessing all types of work. There were previously two separate technical manuals for CEEQUAL Term Contracts Version 5 (‘Construction of small or repetitive works’ and ‘Maintenance’). There is now one technical manual covering all types of work and the contract team have more choice in deciding what requirements are within the scope of the work types being assessed as part of the contract.
- More flexibility in assigning criteria between contract management and activity delivery. Question scores were previously associated with either ‘Contract management’ or ‘Activity delivery’. The contract team now has flexibility to choose where individual requirements are scored.
- Simpler fee structure. The fees are based on the contract value of the works being undertaken within the assessment cycle. They are raised one month prior to the commencement of each assessment cycle until the last assessment cycle of the contract. Verification fees are charged one month prior to each assessment cycle verification and are calculated on the number of work types.
The scheme is available for use both internationally and in the UK and Ireland.
View the technical manuals
Train to become a Term Contracts Assessor
Existing V6 Project Assessors can complete
an online top-up training course to qualify as BREEAM Infrastructure Term Contract Assessors.
For new assessors, there is a two-day
BREEAM Infrastructure Term Contracts Assessor course.
Find out more
To find out more about using Term Contracts, visit the
BREEAM webpages or contact us at
breeaminfrastructure@bregroup.com.
Information correct as of 30thNovember 2026. Please see kb.breeam.com for the latest compliance information.