UKNC: Residential (HQM) / HQM V6 /
00 General
Information correct as of 8thNovember 2026. Please see kb.breeam.com for the latest compliance information.
HQM – Update to Building Regulations & SAP 10 - KBCN1553
We have incorporated the Building Regulations changes into HQM V6.
HQM V6 (which has been published and is available for assessors to use) is compatible with SAP 10.
30/10/23-Updated compliance note to confirm HQM V6 is compatible with SAP 10
Minimum requirements have been missed due to the late engagement with HQM V6 - KBCN1609
Where it can be shown that a time-critical minimum requirement has been missed due to the late engagement with HQM, the timing aspect can be waived.
However, it must be demonstrated that the criteria are met as far as possible and any resulting impacts are mitigated.
Principal contractor or subcontractor no longer operational - KBCN0590
In situations where the principal contractor or other company involved in the project is no longer operational where, for example, the company has gone into administration, the assessor may be unable to obtain all the evidence to meet the requirements of BREEAM or HQM.
For some BREEAM Issues, it may not be possible to demonstrate compliance retrospectively, and in such cases, the relevant credits must be withheld.
However, in this situation, a lack of complete evidence will not, in itself, prevent the project from achieving a BREEAM rating and, where relevant, a prerequisite or minimum standard can be waived. For example:
UK NC V6 Man 03 Prerequisite - Legally harvested and traded timber
or
INC V6 Wst 03a – 1 credit to achieve an Excellent Rating
This is based on the project team demonstrating appropriate efforts to obtain the evidence from the company in administration and providing the following:
- Evidence of the company going into administration
- Evidence of compliance from the company in administration, where available
- Evidence of compliance from the date a new company was engaged
28 Oct 2024 - Title and general approach updated. Applied to HQM One/V6 and NC V6.
Scheme classification for residential projects (UK) - KBCN1225
Choosing the right scheme for developments is the starting point to ensure successful outcomes and value, in terms of quality and sustainability to building owners and for occupants of the building.
In light of the release of Home Quality Mark (HQM) ONE we have reviewed the existing guidance around scheme classifications of new build residential buildings and have removed ‘GN03 – Scheme Classification – Domestic buildings’ from BREEAM Projects.
When GN03 was written, the Code for Sustainable Homes (CSH) did not fully consider communal areas within residential blocks as part of the assessment. CSH was also not applicable in Scotland. GN03 was developed to clarify the differences between BREEAM Multi-Residential, CSH and EcoHomes, and when each scheme should be applied.
There is now a clearer distinction between BREEAM Multi-residential and HQM and when these should be used. Ultimately, the determining factor for a scheme classification is now focused on the intent of the building and who is going to be the end user (as opposed to previous guidance which considered aspects such as percentage of communal areas, etc.). Broadly, if the building’s main purpose is for long term homes then Home Quality Mark is the correct scheme to use.
Please use the following as guidance to identify the most appropriate scheme:
UKNCR / Home Quality Mark (HQM)
HQM has been designed with the occupant in mind. It assesses homes individually, but can also account for common areas associated with blocks of self-contained homes. HQM outputs (rating and indicators e.g. ‘my cost’, ‘my wellbeing’ and ‘my footprint’) are specifically aimed at those living in the home and are designed to better inform the occupant about the benefits of the home that they are purchasing or renting.
An HQM project will meet one or more of the following criteria:
Be designed to meet the function of a long-term self-contained home even though there may be some provision of communal facilities which can be used on a voluntary basis
Be classified under Building regulations Part L1a (i.e. required to complete SAP assessments, although there may be some linked SBEM assessed spaces associated with the project)
As such, HQM projects could be homes for sale, social housing or homes for rent (PRS and Built to Rent). They may also include some student and retirement/sheltered accommodation where the units are comparable to a normal self-contained flat/home.
BREEAM Multi-residential
For the purposes of BREEAM Multi-residential assessments, the term ‘multi-residential’ is used in the context of buildings that contain rooms for residential purposes alongside communal facilities for catering, leisure, care etc. These residential rooms would normally not have the full, self-contained functions of a home. This scheme usually covers more specialist residential care homes, student halls of residence, and other more communal accommodation. The scheme can cater for a small number of self-contained dwellings where these form part of a larger multi-residential development (e.g. on-site warden homes etc.). Under this scheme, the project is assessed on a whole building basis and as such does not seek to reflect the performance of individual residential units/rooms.
A BREEAM Multi-residential project will meet one or more of the following criteria:
Be provided for transient /non-permanent occupants
Provide suitable accommodation for occupants requiring support from carers, wardens or similar
Include shared living spaces
Be classified under Building regulations Part L2a (i.e. required to complete SBEM assessments, but can account for some SAP assessed spaces where associated with the project)
As a rule of thumb, if the building contains
rooms rather than self-contained flats or homes, a BREEAM Multi-residential assessment would probably be most appropriate. We are aware of some confusion over the meaning of the term ‘multi-residential’ in this context and will be considering the use of term as part of the next review of the BREEAM Multi-Residential scheme.
If you are unsure of the appropriate scheme classification for a particular project, please contact the BREEAM office before registering the project.
11-Nov-2025 - Applicability to current UKNC, HQM and UKNCR confirmed
Summary of changes – HQM V6 - KBCN1604
Home Quality Mark Version 6 (HQM V6) is an update to Home Quality Mark ONE (HQM ONE) following changes to building regulations in the UK. The update incorporates changes to the building regulations in England, Scotland, and Wales, and makes the scheme available for use for the first time in Northern Ireland. The
technical manual was released on 28 June 2023.
HQM V6 enables new homes in England, Scotland, Wales, and Northern Ireland using the latest building regulations for energy performance to register and complete HQM assessments.
The updates are limited in scope, with the main changes to the scoring and awarding of credits in:
- 5.1 Energy and carbon performance (previously 5.1 Energy and cost)
- 4.5 Temperature
There are minor changes to the criteria, methodology, or definitions in:
- 1.2 Sustainable transport options
- 4.1 Indoor pollutants
- 4.4 Sound insulation
- 4.6 Ventilation
A full summary of the changes is provided in the table below. The update includes corrections throughout the manual for minor known issues and typographical errors in HQM ONE.
Relevant knowledge base compliance notes (KBCNs) from HQM ONE can continue to be applied to HQM V6.
| Location |
Description of change |
| All / throughout |
Updated references to building regulations. |
| All / throughout |
Update to the countries where HQM can be used; including Northern Ireland. |
| All / throughout |
Updated references to the latest versions of standards, publications, and guidance. |
| 1.1 Public transport availability |
Correct crit 2c and methodology for ‘Calculating the average number of services’ (remove “and off-peak”). |
| 1.2 Sustainable transport options |
Remove the option of achieving credits for slow charging infrastructure (3 kW) for electric vehicles (EV). |
| Remove reference to hybrid vehicles in crit 11. |
| Add clarifications to definitions for ‘Cycle storage locations’ and ‘Cycle storage requirements’. |
| 2.5 Recreational space |
Updated definition for ‘Communal space’ to include individual spaces over 20m2 (previously 50m2). |
| 3.3 Security |
Updated definition for ‘Suitably Qualified Security Specialist (SQSS)’. |
| Remove definitions for ‘Architectural Liaison Officer (ALO)’, ‘Crime Prevention Design Advisor (CPDA)’, and ‘Designing Out Crime Officer (DOCO)’. |
| 4.1 Indoor pollutants |
Remove reference to system 2 ventilation systems (passive stack ventilation) for homes in England and Wales following changes to the terminology used in building regulations. |
| Updated TVOC concentration threshold in crit 10 to 300 µg/m3 (previously 500 µg/m3). |
| 4.3 Noise sources |
Add updates and clarifications to the methodology for ‘Internal noise levels – habitable spaces and kitchens’. |
| 4.4 Sound insulation |
Remove the “Robust Details” option for ‘Sound insulation between homes’. |
| Correct minimum sound insulation level for internal walls and floors (‘Airborne sound insulation Rw’) to 43 dB for two credits (was 44 dB). |
| 4.5 Temperature |
Updated scoring requirements for assessments in England to recognise projects going beyond the methodologies in the latest version of Approved Document O. |
| Updated requirements for the foundation route (HQM temperature tool). The number of credits available for the foundation route has been reduced to 6 credits. A new HQM temperature tool is now available for HQM V6. [Change introduced in HQM 6.0.2. See October 2023 Process Note.] |
| 4.6 Ventilation |
Updated terminology used for ventilation systems to reflect updates to buildings regulations in England and Wales. |
| Updated minimum ventilation rates according to the number of bedrooms (Table 26). |
| 5.1 Energy and carbon performance |
Updated the energy performance methodology to use the latest building regulations for operational energy in each UK country. Includes updates to the HEPR benchmark scale and the total number of credits available for ‘Energy performance’. The methodology is described in the technical manual. |
| Updated the credit benchmark scale, including the total number of credits available, for ‘Beyond zero net regulated carbon’ (previously ‘Towards carbon negative’). |
| Remove the 'Cost' credits. The credits have been reassigned to ‘Energy performance’ and ‘Beyond zero net regulated carbon’. |
| 5.3 Impact on local air quality |
Correct NOx emissions levels for oil boilers. Update ‘7 credits (Low pollution locations)’ and ’10 credits (Low pollution locations)’. |
| 7.1 Drying space |
Updated energy efficiency class for washer-dryers to use new EU energy labels that came into force on 1 March 2021. |
| 11.1 Aftercare |
Clarify crit 2d (add “…must be communicated to the occupants during aftercare visits”). |
| 11.4 Post occupancy evaluation |
Updated requirements in methodology for ‘POE 3. Water audit’ (remove “with readings recorded at least every hour”). |
| (Multiple) |
Updated and corrected entries in evidence tables for 10.2 Construction energy use, 10.3 Construction water use, 11.3 Smart homes, and 11.4 Post occupancy evaluation. |
| Appendix A |
Updated ‘My Cost’ and ‘My Footprint’ indicator backstops following changes to credits in 5.1 Energy and carbon performance. |
| Appendix B |
Updated section on ‘Pre-approval of HQM assessment issues and criteria’. |
08 Nov 2023 - Updated following the release of HQM 6.0.2. New entry added to table for 4.5 Temperature.
Information correct as of 8thNovember 2026. Please see kb.breeam.com for the latest compliance information.