Infrastructure / Projects /
International
Information correct as of 7thNovember 2026. Please see kb.breeam.com for the latest compliance information.
Biodiversity Net Gain – Sites with a zero baseline - KBCN1884
When assessing a site with no ecological features, pre-development, the "BREEAM-CEEQUAL-HQM-Change-in-Ecological-Value-Calculator" tool available in BREEAM Projects, can be used to calculate the percentage biodiversity net gain from a zero baseline.
This method caps the percentage biodiversity net gain, so the maximum number of credits that can be achieved using this approach is as follows:
- BREEAM UK New Construction 2018/V6 = 3 credits
- BREEAM UK New Construction Residential V6.1 / Home Quality Mark = 6 Credits
- BREEAM Infrastructure V6 = 30 Credits
The cap on percentage biodiversity net gain seeks to ensure comparability between assessments, as it may be easier to achieve a high score from a zero baseline.
Minimum standards – Scope out - KBCN1681
Any BREEAM Infrastructure criteria agreed for ‘scope out’ within an assessment are removed from the assessment in their entirety. This applies to criteria marked as a ‘minimum standard’. When seeking to achieve an Outstanding rating, where one or more of the ‘minimum standard’ criteria are scoped out, these no longer contribute to achieving an Outstanding rating.
For example, if criterion 7.2.2 is agreed for ‘scope out’, the minimum standard will be based on achieving a score greater than 90% and meeting criteria 2.1.2, 2.1.3, 4.4.1 and 7.4.2.
Norwegian Approved Standards List (ASL) – BREEAM Infrastructure - KBCN1774
The Approved Standards List for Norway is a record of all local codes and standards that BRE Global has approved to date for the BREEAM Infrastructure scheme. The list is periodically updated to reflect recent approvals or withdrawals.
Local best practice codes and standards can be submitted to BRE Global to substitute for the standards described in the criteria in the scheme Technical Manuals. Provided that such standards are equivalent to the BREEAM specified standards.
Please see the ASL Norway document within the BREEAM Infrastructure documents folder on BREEAM Projects, which contains the Norwegian national best practice standards and/or tool reference and the relevant BREEAM Infrastructure criteria:
BREEAM Projects - Other BREEAM Infrastructure Documents
The standards listed within this document are approved by BRE and are considered a suitable counterpart to the UK/International best practice standard, tool or scheme listed in the BREEAM Infrastructure V6 International Projects or Term Contracts technical manual. The Norwegian standards, tools and schemes listed can be evidenced, referenced or used in place of those identified.
Norwegian ASL version
The version of the ASL that is current at the time of registration is the one that is used for assessment. Newer versions released after this can also be used, however older versions before the registration date cannot be used.
For example: if the version current at registration was v3.0, then v4.0 (or any later versions) can be used, but v2.0 (or any earlier versions) cannot be used.
Standard versions and proposing new standards
Where a standard has been updated, it is not automatically added to the ASL template as the scope of the standard may have changed. If you wish to propose a new standard which you think is more relevant, or if an existing local standard has been replaced or updated, please contact BREEAM Infrastructure (
breeaminfrastructure@bregroup.com). This information will then be shared with Grønn Byggallianse (Norwegian Green Building Council), the NSO for Norway, and the standard reviewed for applicability.
PAS 2080:2023 – BREEAM Infrastructure - KBCN1628
An updated version of PAS 2080 was released in April 2023 (PAS 2080:2023), superseding the previous version (PAS 2080:2016).
The latest version of PAS 2080 may be used in BREEAM Infrastructure assessments in place of the previous version. The equivalent, relevant clauses are given in the table below.
| PAS 2080:2016 (original) |
PAS 2080:2023 (updated) |
| Clause 7 – Quantification of GHG emissions |
Clause 7 – Whole life carbon assessment principles to support decision-making |
| Clause 8 – Target setting, baseline setting and monitoring |
Clause 8 – Target setting and baselines |
| Clause 9 – Reporting |
Clause 9 – Monitoring and reporting |
| Clause 10 – Continual improvement |
Clause 11 – Continual improvement |
| Clause 12 – Claims of conformity |
Clause 12 – Claims of conformity |
The references to specific clause numbers for claims of conformity remain unchanged (part of Clause 12 in PAS 2080).
The latest version of PAS 2080:2023 is available to download from BSI:
https://knowledge.bsigroup.com/products/carbon-management-in-buildings-and-infrastructure
An updated guidance document for PAS 2080:2023 is available from ICE:
https://www.ice.org.uk/engineering-resources/briefing-sheets/guidance-document-pas2080
Scoping criteria requirements – Award types that exclude project stages - KBCN1682
The following award types all exclude one or two project stages from an assessment:
• Strategy & Design
• Design & Construction
• Design Only
• Construction Only
This can make it challenging to understand how to deal with situations where criteria refer to a stage or requirement that is not assessed as part of the award type. This is particularly prevalent for Construction Only Awards.
It may be tempting to scope out these criteria because the required measures are ‘not in the design brief’ or ‘not our responsibility’. However, before scoping out any criteria, it must be considered whether the requirements could have been met, regardless of whether relevant measures were specifically asked for.
‘Scope out’ is determined by relevance. For example, in a Construction Only Award, the contractor should consider what measures they can take to meet the requirements without the assistance of the client or designer.
Tools for LCA calculation in Norway – Life cycle assessment - KBCN1712
Some commonly used tools in Norway, such as vegLCA and NV-ghg, are observed to lack coverage of module C, which is required under criterion 7.3.1 for Life Cycle Assessment to achieve a higher level of performance beyond a Product LCA.
If a project uses these tools, only a Product LCA can be achieved unless supplementary calculations addressing module C are included in the submitted evidence.
Information correct as of 7thNovember 2026. Please see kb.breeam.com for the latest compliance information.