Biodiversity Net Gain – Sites with a zero baseline - KBCN1884
When assessing a site with no ecological features, pre-development, the "BREEAM-CEEQUAL-HQM-Change-in-Ecological-Value-Calculator" tool available in BREEAM Projects, can be used to calculate the percentage biodiversity net gain from a zero baseline.
This method caps the percentage biodiversity net gain, so the maximum number of credits that can be achieved using this approach is as follows:
- BREEAM UK New Construction 2018/V6 = 3 credits
- BREEAM UK New Construction Residential V6.1 / Home Quality Mark = 6 Credits
- BREEAM Infrastructure V6 = 30 Credits
The cap on percentage biodiversity net gain seeks to ensure comparability between assessments, as it may be easier to achieve a high score from a zero baseline.
PAS 2080:2023 – BREEAM Infrastructure - KBCN1628
An updated version of PAS 2080 was released in April 2023 (PAS 2080:2023), superseding the previous version (PAS 2080:2016).
The latest version of PAS 2080 may be used in BREEAM Infrastructure assessments in place of the previous version. The equivalent, relevant clauses are given in the table below.
| PAS 2080:2016 (original) |
PAS 2080:2023 (updated) |
| Clause 7 – Quantification of GHG emissions |
Clause 7 – Whole life carbon assessment principles to support decision-making |
| Clause 8 – Target setting, baseline setting and monitoring |
Clause 8 – Target setting and baselines |
| Clause 9 – Reporting |
Clause 9 – Monitoring and reporting |
| Clause 10 – Continual improvement |
Clause 11 – Continual improvement |
| Clause 12 – Claims of conformity |
Clause 12 – Claims of conformity |
The references to specific clause numbers for claims of conformity remain unchanged (part of Clause 12 in PAS 2080).
The latest version of PAS 2080:2023 is available to download from BSI:
https://knowledge.bsigroup.com/products/carbon-management-in-buildings-and-infrastructure
An updated guidance document for PAS 2080:2023 is available from ICE:
https://www.ice.org.uk/engineering-resources/briefing-sheets/guidance-document-pas2080
Information correct as of 22