UKNC: Residential (HQM) / HQM V6 / B My Home /

4 Comfort

Information correct as of 1stNovember 2026. Please see kb.breeam.com for the latest compliance information.

Accreditation – sampling and testing laboratories - KBCN1337

Accreditation of organisations performing laboratory analysis and testing of emissions: NC 2016 or newer All organisations conducting indoor air analysis or emissions testing of building products must be accredited to ISO/IEC 17025, with specific accreditation covering all applicable chemical analysis and emission testing methods relevant to their scope. The accreditation must be carried out: either Accreditation of organisations performing sampling: If sampling and analysis is carried out by two separate organisations, then sampling organisation does not need to be accredited to the above. However, they must provide a brief report justifying: This report is provided to the BREEAM assessor and submitted as supporting evidence for this issue
30-Oct-2025 Applicable to HQM V6
06-May-2025 Comprehensively updated to clarify the requirements.
31-Oct-2022 Wording clarified. Scheme applicability updated.
10-Oct-2022 Title amended for clarity. Scheme applicability updated.
24-May-2022 Updated to differentiate between sampling and analysis requirements. 
07-May-2021 Added clarification regarding alternative qualifications. 
10-May-2021 Updated scheme applicability.

Communal ventilation system - KBCN1388

A communal ventilation system is acceptable as long as it meets the requirements in the HQM manual. In terms of maintenance, if it is not possible for the home occupants to carry out system maintenance themselves due to the type of system installed we would need a statement from the professional designing the system stating this. Instead, any specified ventilation system requiring maintenance must be designed to allow building services engineers to easily complete the work in a safe manner in accordance with manufacturer’s instructions and any other safety regulations, to prevent systems becoming redundant or being unable to function to their designed intention.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1

Compliant test body – alternative compliance route using a Suitably Qualified Acoustician - KBCN1412

Where acoustic testing and measurement has not been performed by an organisation or individual that meets the definition of a compliant test body, compliance with this requirement can still be demonstrated where a Suitably Qualified Acoustician has reviewed the relevant test report(s). The test report must: a) Be countersigned or authorised by a Suitably Qualified Acoustician b) Include a clear statement that the acoustic testing and measurements have been carried out in accordance with the BREEAM or HQM testing requirements AND c) Include evidence that the verifier meets the definition for a Suitably Qualified Acoustician within the relevant BREEAM or HQM technical manual
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1

Emissions from products – scope of assessment - KBCN0212

General This issue covers any product installed or applied inside the inner surface of the building’s infiltration, vapour or waterproof membrane. Where this membrane is not present, it applies to the inside of the building envelope’s interior-facing thermal insulation layer. Only products that are installed or applied in parts of the building where their emissions are likely to affect indoor air quality need to be assessed. Paints and coatings Any decorative paints and varnishes that occupants are exposed to should be assessed. This is likely to include paints and coatings applied to walls, ceilings, floors, doors, etc. Whole products A finish applied to a product in the factory is assessed as a whole product, and not separately as a paint or coating. For instance, a wood panel has a finish applied in the factory. The whole panel, including all the elements that make up that panel, would need to comply with the requirements set for wood panel products in this issue. The finished product as a whole must meet the performance requirements / emission limits set in the manual.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
11-Oct-2022 - Title amended for clarity and consistency. Content merged with KBCN0871.
10-Oct-2022 - Wording simplified. Scheme applicability updated.
16-Jun-2017 - Title and general principle amended to extend the applicability of the KBCN to all finishes. Paints specified for specialist applications covered in KBCN0872.
 

Emissions from products – specialist paints and coatings - KBCN0872

Where a paint or coating falls within: then the paint or coating must be assessed. Specialist paints and coatings are exempted from meeting the VOC content and emission limits where there are no alternative products available that can perform the function, and still meet the emission limits. This must be clearly evidenced.
30-Oct-2025 Applicable to HQM V6 and UKNCR V6.1
02-Oct-2025 Reference to 'VOC content' added and KBCN applied to UKNC V7 and INC V7 to clarify CN2.1 
27-Oct-2022 Wording clarified. New compliance principle added from UKNC V6.
10-Oct-2022 Title amended for clarity. Scheme applicability updated.
13-Mar-2020 KBCN amended to clarify exceptions and applicability.
16-Jun-2017 Content merged with KBCN0212.

GN22 Recognised schemes for emissions from construction products - KBCN0719

Latest version: v3.3, October 2026 Within the Health and Wellbeing category of several BREEAM schemes, credits are awarded for specifying materials that minimise emissions from building products of formaldehyde and volatile organic compounds (VOCs). The criteria involve meeting emission level performance requirements in accordance with compliant performance and testing standards. Guidance Note 22 (GN22) lists schemes that show equivalent or better performance than the current BREEAM and HQM criteria and therefore can be used to demonstrate compliance with the criteria. This document should be read in conjunction with the relevant assessment issue guidance provided in the appropriate BREEAM or HQM technical manual. The guidance note contains two tables: Download Guidance Note 22 View all Guidance Notes on BREEAM Projects (licensed assessors only) Applying for inclusion in GN22 The list of approved schemes is based on those which have made a successful application to BREEAM. As such, there may be other operational schemes that could potentially be recognised. To be considered for inclusion, the scheme operator must complete an application form, providing full details of the scheme, and submit this to BRE Global for technical approval. A flat rate charge is payable to cover the costs of administering and reviewing the application. GN22 will be updated following the approval of any schemes via this process. The application form (BF1648) provides full details of the application process, and licensed BREEAM assessors can request a copy by submitting a technical query using the webform. Other parties may request a copy by contacting: breeam@bregroup.com
28-Oct-2026 - Release of GN22 3.3
15-Jul-2026 - Release of GN22 3.2
25-Mar-2026 - Release of GN22 3.1
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
25-Sep-2025 - Updated to provide details of the approval process and title updated.
30-Jan-2025 - Release of GN22 3.0
30-Sep-2024 - Release of GN22 2.9
01-Feb-2024 - Release of GN22 2.8
31-Jan-2023 - Release of GN22 2.7
10-Oct-2022 - This KBCN merged with KBCN0646. Title amended to align with standard KBCN naming format for clarity and consistency. Made applicable to UK and International NC V6.
25-Jan-2019 - Link to Guidance Note updated
12-Mar-2018 - Link to Guidance Note updated

Information sign provided via a QR code - KBCN1875

A QR code securely fixed to the rear of a boiler, meter, or airing‑cupboard door that, when scanned, provides the required digital information for Crit 1 is acceptable as an alternative to a physical information sign.
Where a QR code is provided, crit 1.f. is not applicable. Where a QR code is provided, information detailing how to request a hard copy must also be provided for those occupants who cannot access the information digitally as they do not have a smart device with an internet connection..

Minimum ventilation rate above boost flow rate - KBCN1364

Where a ventilation system has the capacity to meet the minimum ventilation rate (Criteria '03 Ventilation rates') and where this is above the boost flow rate, then the boost flow rate can be deemed to have been met by default.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1

Recognised emission certification schemes – Publicly available databases - KBCN1887

Some of the emission certification schemes recognised within GN22 maintain publicly available databases of products certified against their scheme requirements. These databases can be used to help assessors and project teams identify products that are certified under recognised schemes. Examples include: EU Ecolabel – https://environmental-data.ec.europa.eu/ecolabel/index.html GREENGUARD – https://spot.ul.com/ Indoor Advantage – https://www.scsglobalservices.com/certified-green-products-guide Nordic Swan – https://www.svanen.se/en/search-for-ecolabelled-products-and-services/?sortorder=6&producttype=0&qry=&productgroup= Blue Angel – https://www.blauer-engel.de/en eco-INSTITUT – https://www.eco-institut-label.de/en/ M1 – https://ymparisto.rakennustieto.fi/rakennusmateriaalien-paastoluokitus-etsi-m1-luokiteltuja-tuotteita Indoor Air Comfort® / Indoor Air Comfort Gold® – https://www.eurofins.com/iac-certified   Please be aware that these databases may include products that are certified under a recognised scheme, but which fall outside the product categories, BREEAM performance level, or the approved certification level recognised in GN22. Assessors must, therefore, verify that the certification scheme and product category are recognised within GN22 and applicable to the product being assessed. Please also refer to KBCN0719 - GN22 Recognised schemes for emissions from construction products

Sound Insulation testing for Cupboards - KBCN1299

A cupboard (even built in) does not constitute a room and does not need to be assessed for the 'Sound insulation levels for internal walls and floors' credits as it is not permanent (part of the home's fabric) and also non-habitable.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
 

Sound testing between rooms - KBCN1303

Only lab tests carried out in accordance with Part E of the building regulations are accepted as evidence to show compliance with the requirements sound insulation between rooms ( 02 Sound insulation levels for internal walls and floors - HQM ONE). In-situ testing and software calculations are not acceptable ways of  showing compliance.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
 

Ventilation air intakes CIBSE TM21 compliance - KBCN0669

As TM21 largely contains general guidance, rather that strict rules, it is expected that the designer or services engineer would be familiar with the requirements within TM21 and be able to determine which sections are relevant for the development in question. The main areas to consider in relation to TM21 are: • Provision of filtration • Positioning inlets to minimise impacts of traffic pollution • Positioning inlets to minimise impacts of other local sources of pollution • Positioning inlets to minimise recirculation from ventilation exhausts Confirmation is required that each of these items (and anything else the designer/engineer deems relevant) has been considered in determining the location of air intakes. Suitable evidence may for example be in the form of a short report with diagrams indicating the proposed location of intakes, with respect to sources of pollution and with reference to the relevant parts of TM21.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1

VOC product emission certificates – validity - KBCN1689

Where it can be demonstrated that construction product emission certificates were valid either at the time of specification, or at time of purchase, they may contribute to awarding credits.

BREEAM is primarily trying to encourage designers to take construction product emissions into consideration when specifying or selecting products and as such it is not necessary for certification to be valid at the time of design or post-construction stage submissions.

30-Oct-2025 - Applicable to UKNCR V6.1

Information correct as of 1stNovember 2026. Please see kb.breeam.com for the latest compliance information.