Car sharing – aim and principles - KBCN1510
Aim
The aim of this measure is that the asset’s management establishes, promotes and administers a process which encourages building users to share private car journeys to and from work, reducing the number of cars used for this purpose.
Principles
A car sharing group will, generally:
- Be available to all building users who normally travel to work by private car.
A car sharing group is not:
- A vehicle hire/loan scheme.
- Intended to offset journeys which would otherwise have been made by public transport or active travel modes (e.g. walking or cycling).
The criteria do not prescribe what terms and conditions should be implemented and, whilst the above principles should generally be followed, specific arrangements may vary.
Evidence and justification must always be provided to demonstrate that the above aim is met.
21-Jul-2026 - Scheme applicability updated. Title updated for clarity and consistency.
Car sharing – location of priority parking - KBCN0796
Priority spaces for car sharers need to be located in the nearest available parking area to the main building entrance or to an entrance regularly used by the car sharers.
For refurbishment projects, this applies regardless of whether external works or changes to car parking areas are within the scope of works.
Assigning and clearly marking out the location of priority parking spaces is a measure that can be taken by any project regardless of scope, provided there are suitable external parking areas.
21-Jul-2026 - Scheme applicability updated. Wording expanded to clarify how KBCN applies to refurbishment projects. Title updated for consistency.
22-Sep-2022 - Applied to UK NC 2018.
Car sharing – speculative projects - KBCN0878
This measure will generally be unavailable to speculative projects.
To fully implement the car sharing option, the building occupants need to be known and signed up to a car sharing scheme in line with the criteria.
21-Jul-2026 - Scheme applicability updated. Title updated for clarity.
Car sharing – calculation of priority spaces - KBCN0282
The calculation of priority spaces for car sharers should account only for the car parking capacity that is dedicated to the staff working in the building, without considering spaces for customers or visitors.
Car sharing spaces should be clearly segregated from customer / visitor parking areas.
21-Jul-2026 - Scheme applicability updated.
06-Sep-2023 - Title updated to align with naming protocol.
23-Mar-2017 - Note added clarifying requirement for segregation.
Cyclists’ facilities – Shell only/shell & core assessments - KBCN0882
Cycle parking must be provided as part of the base-build for all assessment types.
Where compliance is sought for additional cyclists’ facilities, the developer should provide all aspects of the installation which fall within the scope of their work and facilitate the future completion of any aspects which do not.
For shell & core assessments, if additional facilities, such as showers and drying space, are not provided in core areas and internal walls are not provided to tenanted areas, these must be indicated on design drawings and all relevant services provided. This would include capped-off supplies and electrical points as necessary in order to facilitate the completion of the compliant facilities by the tenant.
Where internal walls are within scope, a compliant changing area must be provided, however for lockers, compliance can be achieved by providing a design drawing showing that there is an adequately sized and suitably located space for the required number of compliant lockers.
The developer should do as much as they can, within the scope of their work, to facilitate the future installation of compliant facilities and should not do anything which would make future installation more onerous.
01 Oct 2024 - Addition paragraph added to clarify the approach for changing areas and lockers.
25 May 2018 - Wording amended to clarify the intent.
Hotels and other short stay accommodation – cycle storage unit of measure - KBCN0676
The cycle storage requirement for hotels and other short‑stay accommodation is
1 space per 10 staff. Guests or visitors staying at the hotel are excluded from the calculation.
Where a hotel includes on‑site facilities such as conference spaces, restaurants, or gyms, visitors to these facilities should also be included in the cycle-storage calculation:
1 space per 10 guests.
Specific Note for Refurbishment and Fit Out International 2015
Table 36 in the technical manual incorrectly refers to “1 staff and 1 visitor, or 1 bed.” Please ignore this error and follow the guidance above.
16-Feb-2026 - Wording update to be applicable across multiple BREEAM Schemes
20-Oct-2025 - Guidance clarified and updated to align with all current BREEAM scheme guidance.