New Construction / UK / V7 / 03 - Energy /

Ene 02 - Prediction of operational energy and carbon

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

GN53 Energy modelling and predicted operational energy performance score in Ene 02 - KBCN1751

Latest version: v0.2, February 2026 Guidance Note 53 (GN53) provides guidance for the predictive energy modelling and predicted operational energy performance score credits within Ene 02, detailing the input process for the issue’s operational energy calculator. Download Guidance Note 53 View all Guidance Notes on BREEAM Projects (licensed assessors only)
16-Feb-2026 - Updated for release of GN53 0.2

Independent third party – clarification on the definition - KBCN1805

For the purposes of BREEAM, sister companies or parent companies cannot be considered as third parties.  To be classed as an independent third party, there must be no professional connection or relationship between the LCA consultant/energy assessor, or their company, and the verification body. The third-party verifier must be independent of the LCA or energy assessor and demonstrate impartiality (for general principles, see ISO 17029). To qualify as a third party, the verifier must belong to an organisation not involved in the project and must not provide advice to the project, as this could compromise their impartiality during verification.

Predicted operational energy performance score – Credit table update - KBCN1825

From 4th February 2026, the following credit table applies to Ene 02 in all BREEAM International New Construction V7 and BREEAM UK New Construction V7 assessments: *Alternatively meet the minimum EPRNC score specified for Excellent in Ene 01. **Alternatively meet the minimum EPRNC score specified for Outstanding in Ene 01. The OEPNC scores required for each credit boundary have been lowered on the BREEAM platform in response to assessor feedback and an internal review of credit attainment against our benchmark database. The table above supersedes: - Table 28 in BREEAM International New Construction V7 - Table 6.3 in BREEAM UK New Construction V7 For further guidance on Ene 02 and the achievement of OEPNC scores please refer to KBCN1751 - GN53 Energy modelling and predicted operational energy performance score in Ene 02. The above updated credit table will be included in the next reissue of the technical manuals

Prediction of operational energy and carbon – PHPP - KBCN1915

In applicable scheme versions (please see above), PHPP (Passive House Planning Package) will be considered as a compliant modelling approach for the prediction of operational energy (and carbon). This applies only to homes and small non-domestic buildings, where the building services are limited to: This methodology cannot be used where the building services include central air handling, mechanical cooling, or air conditioning.