Refurbishment and Fit Out / UK RFO 2014 / 06 - Materials /
MAT 01 - Environmental Impact of Materials
Information correct as of 29thNovember 2026. Please see kb.breeam.com for the latest compliance information.
Assessing basement external walls - KBCN0241
Only the external walls above ground level are required to be assessed under 'external walls'.
The external walls below ground (i.e. within a basement area) perform a specialist function, these are not comparable with other external walls in a building. These are included in the 'basement retaining walls'.
20/08/2021 Scope clarified in accordance with the New Rules of Measurement (NRM) by the Royal Institute of Chartered Surveyors (RICS).
Astroturf (artificial grass) - KBCN0106
This is not be considered as hard landscaping and should be excluded from the assessment of this issue.
Boundary Protection - KBCN0753
Only boundary protection specifically forming the site boundary should be included in the calculations. This may not necessarily be located on the boundary of ownership, but is the physical barrier which ostensibly encloses the development.
Any other freestanding walls or fencing within the site can be excluded.
BRE Environmental Profile certificates - KBCN0777
BRE Environmental Profile certificates are compliant EPDs and can be used as evidence for the purposes of Mat 01.
Building LCA tools recognised by BREEAM - KBCN1118
The following document shows the building LCA tools that are recognised by BREEAM for each BREEAM scheme. Only submissions from the tools listed here will be accepted as part of a BREEAM assessment.
These recognised tools may be either an IMPACT Compliant tool or another type of building LCA tool that has been evaluated by BREEAM and considered suitable for carrying out building LCA according to BREEAM’s scheme specific requirements. To apply for a new tool to be evaluated, please contact:
breeam@bregroup.com
Where more than one version of the same tool is listed for a given scheme version, the most recent version of the tool (that is available at the point building LCA work commences on the project) should be used.
It is acceptable to use subsequent, more recent releases/versions of a recognised tool (that have the same name as shown in the table).
View Building LCA tools recognised by BREEAM.
Table updated to new downloadable format, with new layout and new recognised LCA tools and corrections added 01/03/2024
Table updated to include new recognised LCA tools and corrections 10/11/2023
Table updated to include new recognised LCA tools and corrections 22/07/2022
Table updated to include new recognised LCA tools 12/03/2021
KBCN updated for clarity regarding subsequent tool versions on 10/03/2021
Cut-off threshold for responsible sourcing - KBCN1409
For projects pursuing the one separate credit under Responsible Sourcing of Materials (where at least three of the material types listed in the material categories have been responsibly sourced), any material type which clearly accounts for less than 1 m³ per 1000 m² of gross internal floor area, can be excluded from the assessment. This applies for materials in any location or use category.
The volume considered should be taken as the construction product's overall external dimensions, including any internal voids and air spaces. Minor fixings (brackets, nails, screws etc.), adhesives, seals and ironmongery would normally fall below this threshold.
Definition – Reused in situ with minor repairs - KBCN1160
This item in Table "Allocation of points awarded" refers to the Relevant definitions section.
This reference is incorrect and should, instead, point to the Compliance Note "Repairs to existing
in situ elements", which indicates that, 'Materials used to repair existing
in situ elements may be excluded provided no more than 20% of the total area; or volume of the existing element is subject to minor alternations, repair or maintenance'.
To be amended in the next re-issue of the technical manual.
EPDs’ validity - KBCN0798
EPDs which have expired or are pending verification at the time the relevant product was specified, cannot contribute to awarding credits. However, it is not necessary that they are valid at the time of the design or post-construction stage submissions.
BREEAM is primarily trying to encourage designers to take EPDs into consideration when specifying products.
04/11/2019 Confirmed applicability to UK NC2018
27/03/2020 Added applicability to Green Guide ratings and ISO 14001 certificates
27/05/2020 Reference to ISO 14001 removed - Whilst the same principle applies, the wording relating to product specification does not - See KBCN1401.
12/08/2021 Clarification regarding the validity of EPDs during QA submission and removal of reference to Green Guide ratings
Evidence requirements for Mat 01 Calculator - KBCN0675
The following evidence requirements, taken from the BREEAM International New Construction 2016 manual, give further information on the evidence that can be used to demonstrate compliance. This will be added to the next manual re-issue and will be required as evidence.
Evidence requirements
Note: Aside from the likely benefit to the environment from teams using LCA tools, the objective for BREEAM is to gather LCA performance data in order to create benchmarks and inform future updates of the scheme. The evidence requirements below are generic, but BRE Global understand that some tools are not able to fulfil all of the criteria. Where this is the case, the tool operator should submit results as close as possible to that required for the tool.
IMPACT compliant tools
A copy of the full IMPACT project or building file submitted by the assessor to BRE Global must be transmitted in the following format:
- For 3D CAD or building information model (BIM) based IMPACT compliant tools: In Industry Foundation Classes (IFC) or the IMPACT Compliant tool’s native format.
- For spreadsheet-based IMPACT compliant tools: IFC, MS Excel or comma-separated variables (CSV) file format.
- Building element categorisation to be according to New Rules of Measurement (NRM) Royal Institution of Chartered surveyors (RICS).
- A table in MS Excel or CSV file format listing each building element with, for each one, the information listed under 2 b, c and d (from the 'other tools' section), along with the NRM classification.
Other tools
An electronic data table or tables of results (suitably cross referenced) generated by the tool, submitted by the assessor to BRE Global must fulfil the following criteria:
Submit a total building environmental impact result for year 0 (installation only) and year 60 study periods, as follows:
- To include individual results for all environmental issues or indicators that the tool or data permits, showing issue or indicators names and units used. Where issues or indicators according to BSEN 15978:2011 are available, these should be used
- Include individual results for each life stage or module, e.g. stages A, B and C (see BS EN 15978:2011). Where the tool further permits, or where complete measurement of the aforementioned stages is not possible, more detail should be provided. For example, BS EN 15978:2011 modules should be used
- The reporting format should be to BS EN 15978:2011 (or equivalent).
Results for each element as follows, to enable project team members and assessors without an IMPACT Compliant tool to check the accuracy of the model:
- Element impact per issue (as above), with units
- Element kg kgCO2e per life stage or module (as above)
- Element quantity, with units
- Element description
- For each material in the element:
- Installed quantities, with units
- Site wastage quantities, with units
- Replace, repair, refurbish quantities, with units
- Reuse, recycling or disposal (landfill, incineration) quantities, with units.
Transmitted in IFC, MS Excel or CSV file format.
Data permissions
Submission of information to BRE Global for the purpose of assessing this issue will be required at QA stage. The submission is deemed to grant permission for the BRE Group of companies to use the information to:
Fulfil BREEAM quality assurance requirements
Conduct further research (using anonymised data), including for the establishment of robust building level life cycle performance benchmarks in BREEAM and BRE associated tools and methodologies.
03.11.2021 Issue 2.0 of the UK RFO technical manual updated. The above is still applicable to previous issues of the manual, as well as the IRFO manual.
Exemptions from hard landscaping and boundary protection - KBCN00062
Where a third party, such as the local authority, enforces strict constraints on the materials that can be used by the project for hard landscaping or boundary protection, and these materials do not achieve a Green Guide rating of A/A+, it is possible to exempt these materials from the assessment of this issue, on the condition that robust evidence confirming this is given.
In this instance the developer does not have control over the materials specified, therefore it is not appropriate to include them in the assessment.
Gabion as boundary protection - KBCN000008
A gabion can be excluded from the assessment if it acts as a retaining wall or any other form of a supporting structure. If it acts purely as a boundary and a generic Green Guide rating cannot be found for a specification, the BREEAM assessor will need to submit a Bespoke Green Guide Query proforma detailing the specification details.
GN08 – Scope of IMPACT compliant tools and data submission requirements - KBCN0621
Scope of IMPACT Compliant (or equivalent) Tools and Data Submission Requirements - BREEAM UK New Construction 2011 and 2014
Introduction
This Guidance Note relates to complying with the exemplary level criteria for route 2, as defined under the Mat01 issue of the BREEAM New Construction 2011 and 2014 versions. It provides information about IMPACT and the level of detail (the Quality Requirements) and file transmission requirements for the Building Information Model (BIM) from IMPACT compliant (or equivalent) tools. It also outlines criteria for demonstrating the equivalence of a proposed alternative to IMPACT compliant tools for BRE Global approval.
View full Guidance Note (licenced assessors only)
View all Guidance Notes (licenced assessors only)
Green Guide – Updated validity requirements - KBCN1466
It has been recognised that, due to the withdrawal of the Green Guide methodology in the current version of BREEAM UK New Construction, some manufacturers are not updating their product certifications against this environmental profiling scheme.
Therefore, where robust evidence can be provided that the composition and properties of such products or materials have not changed since they were certified, the expired Green Guide Rating may be used, where available.
This supersedes the guidance previously provided in relation to Green Guide validity in KBCN0798
Green Guide Rating of raised access flooring - KBCN00016
There are currently no Green Guide ratings available for raised access floors, therefore the components making up the raised floor element itself should be excluded from the assessment of this issue.
24 01 18 Wording clarified to refer to raised floor components only
Green-roofs - KBCN0263
When assessing green roofs, only the structural elements of the roof construction need to be considered i.e. the waterproof layer and above can be excluded. Where Green Guide is being used to assess the issue, it is likely that the online Green Guide Calculator will need to be used to provide a rating for the roof construction.
HQM - For the purpose of HQM, green roofs fall under 3.3 Specialist roof systems therefore should be included in the IMPACT model.
IMPACT compliant software - KBCN0809
For a list of IMPACT compliant tools please see
here
27 Aug 2025 - Corrupted links to resources updated
LCA modelling for multiple BREEAM assessments - KBCN0960
Multiple buildings' assessments
Site-wide approaches are not acceptable and each BREEAM assessment needs to have its own Life Cycle Assessment model (using an IMPACT compliant software tool or equivalent).
This applies in all cases, including when the buildings are on the same plot and are built to the same specifications.
Developing assessment-specific LCA models ensures that material quantities are accurate, refer to the actual building (and building type) and account for external works included within the scope of the specific assessment.
Single building with multiple assessments within it
Where multiple assessments are conducted for different parts of a building, it is acceptable to have a single LCA model covering all assessments. In this case, an explanation of the allocation process used should be provided and the following guidance applies:
- Common elements (e.g. roof, foundations, external walls etc): apportion a percentage of the total impact of the element to each assessment based on their percentage share of the total GIFA (e.g. if an assessment accounts for 10% of the total GIFA, 10% of the element’s impact is apportioned to that assessment).
- Elements that are only in a given assessment (e.g. internal partitions, internal finishes etc): 100% of the impact is allocated to the assessment they are in.
Life cycle environmental impact of curtain walling - KBCN0178
Curtain walling performs two functions – the provision of windows and the provision of external walls. Specifications performing the same function are grouped together in the Green Guide to Specification. This means that curtain walling needs to be modelled as two separate building elements (external walls and windows).
The overall performance of the curtain wall will combine the ratings for the two parts according to their areas. It will depend on the curtain walling system selected, the choice of internal lining and the relevant proportion of glazed and opaque elements.
- For the opaque area of the external wall (Area A in the figure below):
- Select the relevant generic specification from the Green Guide (element category – External walls / Curtain walling, then either aluminium or timber framed and the internal skin specification) and note the rating and element number. If your specification is different from all of the generics, please submit a request for a bespoke rating.
- Enter the rating into the BREEAM Materials calculator with the area for the opaque section of the curtain wall (Area A).
- For the glazed (window-like) area of the curtain wall (Area B):
- Select the relevant specification from the Commercial window element category of the Green Guide. There are two specifications: Aluminium curtain walling system (Element no: 831500016) and Laminated timber curtain walling system (Element no: 831500015)
- Enter the rating into the BREEAM Materials calculator with the area for the glazed (window-like) section of the curtain wall (Area B).
The BREEAM Materials calculator will calculate the overall performance for the curtain walling system. It will also calculate the performance of the building elements and the overall number of credits to be awarded.
Mat 01 / Mat 03 calculator not big enough - KBCN0647
If a project has more specifications than there is rows available in the tool you can group specifications that have the same green guide rating/responsible sourcing level with each of the specifications with the same rating listed in the same row. The proportion that they contribute to the overall area is also combined. For example where a project has 30 different upper floor specifications, if 10 upper floor specifications are A+, 10 are A, 5 are B and 5 are C then you would only need to use 4 lines.
Mat 01 Calculator Option 1 – verified LCA tools - KBCN0237
Before an LCA tool can be recognised by BREEAM, the tool developer must submit evidence to BRE to verify the tool’s points scored in the Mat 01 Calculator.
The LCA tool is then given its own tab in the calculator, which confirms the maximum score the tool can achieve, if used to its fullest extent. Items coloured green within the calculator are locked because they do not change when using the LCA tool. The items in blue should be edited by the design team to confirm the extent the tool has been used on the project. For RFO schemes, the assessment parts must also be selected.
Items listed as ‘N’ in column W ‘
Included in assessment?’ cannot be changed to a ‘Y’, as the LCA tool cannot be used for this element. For example internal doors cannot be assessed by the Green Guide. An element listed as ‘Y’ can be changed to a ‘N’ if the LCA tool has not been used for the element in the assessment.
Column S confirms if the assessed building includes the element and should be included. For example if there are no stairs in the assessment, then this element is removed from the calculation by saying ‘N’ to cell S15 (in the green guide calculator).
12/01/2017 Reference to LCA approved tools updated.
Multiple buildings on the same site - KBCN0559
The areas of hard landscaping and boundary protection that need to be assessed on a site that contains several developments/buildings depends on the scope of works and scope of the assessment(s) being undertaken.
Essentially, the areas that need to be assessed are all the areas of hard landscaping (as defined within the relevant definitions of the credit issue) and boundary protection within the construction zone (again defined within the relevant definitions) that are within the scope of works of the building under assessment.
Therefore, if all buildings on one site are being assessed in one BREEAM assessment, then the hard landscaping and boundary protection related to all of these building's scope of works will need to be assessed.
If there are several buildings with individual assessments and their own defined scope of works, then the hard landscaping and boundary protection applicable to the scope of works of each individual building will be assessed for each associated assessment.
The assessment is concerned with the hard landscaping and boundary protection associated to the project under assessment, i.e. the areas under the control of the project under assessment.
Option 1 scoring based on robustness and extent of LCA - KBCN0674
For Option 1, BRE Global verifies the LCA tool's score within the Mat 01 calculator based on the rigour of the life cycle assessment tool and the extent it is used on the assessment. For this reason, as opposed to the UK New Construction schemes, the performance/scoring of building elements is not to be taken into consideration and Green Guide ratings for building elements are not linked to the scoring of the Mat 01 tool and credits achieved.
Please see KBCN0237 for further details on using the calculator with verified LCA tools.
Option 2 – number of credits available - KBCN0963
When choosing to assess under option 2 'Elemental assessment of environmental performance information', the online tool allows 'All other buildings' and 'Industrial' assessments to achieve a maximum of four out of six and one out of two credits respectively.
The exemplary credit is available for both options.
This is to recognise that option 2 is a less detailed and extensive way to demonstrate compliance than option 1 'Project life cycle assessment study', for which the maximum score of six credits can be achieved.
03/04/2018 KBCN wording amended to clarify the maximum number of credits available for different building types.
Option 2 – Use of Green Guide to Specification - KBCN0964
As per the relevant Compliance Note, the Green Guide to Specification can be used to demonstrate compliance with Option 1, as the Green Guide is a compliant LCA tool.
However, Option 2 is an elemental approach, for which the Green Guide cannot be used, as robust environmental performance information for the specific new element needs to be provided.
The Green Guide to Specification only provides generic rating and for this reason it cannot be used to demonstrate compliance with Option 2 criteria.
Playground or other specialist surfaces - KBCN0694
Where the hard landscaping surface is specified to meet safety related performance (e.g. non-slip or soft surfaces for playgrounds) or particular performance related requirements (e.g. specialist sports performance surfaces such as astro-turf, netball courts and running tracks), then these surfaces can be omitted from the assessment. The standard specification of surfaces for multi-use areas (e.g. cement, tarmac, asphalt) must still be assessed.
Recycled materials in hard landscaping - KBCN0975
When recycled material is to be used for hard landscaping, the Green Guide rating will depend on whether the material comes from the same site or from another location.
Typically, on-site recycled material is treated with very little impact, or ignored, as there is little or no energy/material input in putting it in place. When recycled material is brought in from elsewhere, transport, as well as any processing the material has gone through to make it fit for purpose, will be taken into account.
If the assessor is in doubt, they need to submit a landscaping proforma along with any supporting documentation on the materials and their use and BRE will provide a rating and/or guidance.
Scope of hard landscaping - KBCN0634
For the purpose of assessment, hard landscaping includes (but is not limited to) parking areas (including manoeuvring areas, lanes, roads within the parking area), pedestrian walkways, paths, patios. The definition excludes basement parking, access or approach roads and designated vehicle manoeuvring areas, balconies, roof terraces,specialist sports areas (running tracks, netball areas etc.) and retaining walls.
The importance of EPDs - KBCN0895
The publishing of a third party verified EPD by a manufacturer indicates a transparent, robust and credible step in the pursuit and achievement of real sustainability in practice. While an EPD in itself is not proof that a product is sustainable, it is a public declaration of the environmental impacts associated with specified life cycle stages of that product. A manufacturer or group of manufacturers, who carry out life cycle assessment (LCA) studies on their product(s) and publish the results in verified EPDs, help to create a knowledge base and an awareness of the environmental impacts quantified using standardised metrics. This allows benchmarking and the identification of improvement opportunities for the product’s environmental credentials. By implication, there are also opportunities for economic and social benefits to the manufacturer, such as the reduction in resource wastage through improvements in product design and manufacturing efficiency.
The reward for EPDs in BREEAM schemes promotes the above, while encouraging designers, procurers and other stakeholders to make decisions on the basis of robust and credible environmental data. This is one of the markers of BRE’s strategic approach to the selection and procurement of construction materials and products.
We recognise that there may be steep costs at the moment to small manufacturers wishing to publish verified EPDs for their products. This is a result of the maturity of the market and it is anticipated that as the awareness of the benefits of EPD increases, the increased uptake of EPDs will drive costs down.
[KBCN withdrawn] – LCA for elements relevant to Parts 2 and 3 - KBCN0750
This KBCN has been withdrawn and is no longer valid.
This is because there are now LCA tools that can be used to address Parts 2 and 3. This is reflected in the relevant Mat 01 tool.
KBCN withdrawn on 19/11/2020:
The elements listed as relevant for Parts 2 and 3 are not covered by any LCA tools approved by BRE at the moment. Tools other than IMPACT that may cover more elements can be used in the future, once they have been submitted to BREEAM for evaluation.
Information correct as of 29thNovember 2026. Please see kb.breeam.com for the latest compliance information.