UKNC: Residential (HQM) / UKNC: Residential V6.1 / B - My home / 6 Materials /

6.2 Building life cycle assessment

Information correct as of 22ndOctober 2026. Please see kb.breeam.com for the latest compliance information.

Clarification of ‘Embodied carbon benchmark comparison’ - KBCN1819

The embodied carbon benchmark comparison must always be based on the latest appropriate LCA stage that corresponds to the BREEAM assessment stage being pursued. The purpose of the benchmark comparison is to assess outcome-based embodied carbon performance, using data that is representative of the building at the relevant assessment stage.

Assessment stage requirements

Interim (Design Stage) BREEAM assessments

Final Post-Construction Stage (PCS) BREEAM assessments

If a PCS LCA is not undertaken, benchmark comparison credits cannot be awarded at final assessment, regardless of whether a technical design LCA was previously completed. This aligns with wider industry frameworks (e.g. RICS WLCA v2 and the UK Net Zero Carbon Buildings Standard), which anchor performance claims to as-built outcomes.

Mixed use buildings (benchmark) – Embodied carbon reporting tool  - KBCN1729

Where the assessed building is mixed use, a comparative, floor-area-weighted benchmark is used to determine the number of credits awarded for criteria ‘06 Embodied carbon benchmark comparison’.   To calculate this, in the ‘Embodied carbon reporting tool’, in the ‘1. Project Input’ tab, enter:  This will enable the tool to calculate the floor area weighted benchmark on the ‘5. Benchmark’ tab