UKNC: Residential (HQM) / UKNC: Residential V6.1 / A - Our surroundings /

1 Transport and movement

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Clarification of ‘rural location’ in England and Wales - KBCN1824

A rural location is defined as any settlement with a resident population of fewer than 10,000 people, including rural towns, villages, hamlets and dispersed dwellings, as set out in the Government’s Rural‑Urban Classification (RUC).
To confirm whether a development is located in a rural location, enter the site postcode into: Web map for Rural Urban Classification (RUC) of Local Authority District Areas (LADs), England and Wales, 2024 | Open Geography Portal Only locations classified as rural within the RUC system are eligible. This includes areas designated as Majority Rural or Intermediate Rural.  

ModeScore Sustainable Transport certification - KBCN1705

Achieving ModeScore Gold or Platinum certification may be used as supporting evidence to award credits for the Transport issues listed in the table below. This alignment is permitted provided that the BREEAM technical criteria are demonstrably met.
Scheme Issues Credits Achievable via ModeScore
BREEAM International NC 2016 and V6 Tra 03a Alternative modes of transport 2 + Exemplary credit
Tra 03b Alternative modes of transport 2 + Exemplary credit
Tra 04 Maximum car parking capacity 1
BREEAM UK NC 2018 and V6 * Tra 02 Sustainable transport measures 10
BREEAM Int RFO 2015 Tra 01 Sustainable transport solutions 5
Tra 04 Maximum car parking capacity 2
BREEAM UK RFO 2014 Tra 01 Sustainable transport solutions 3
Tra 03 Cyclist facilities 2
Tra 04 Maximum car parking capacity 2
BREEAM In Use Commercial and Residential (International and USA) Tra 01 Alternative modes of transport 8
Tra 02 Proximity to public transport 3
Tra 04 Pedestrian and cyclist safety 2
BREEAM UK NC Residential V6.1* 1.1 Public transport availability 3
1.2 Sustainable transport options 17
Evidence Requirements To award credits using this route, the Assessor must:
  1. Submit the ModeScore Certification and Assessment Report.
  2. Provide a mapping statement demonstrating how the targeted BREEAM criteria have been met using the relevant ModeScore criteria.
  3. Provide any Supplementary Evidence identified through the mapping process.
Scheme-Specific Provisions*
About ModeScore Sustainable Transport certification:
ModeScore assess and certifies sustainable transport facilities and services in buildings. ModeScore encompasses ActiveScore within its assessment criteria, covering four pillars of sustainable transportation while incorporating accessibility into each: ModeScore evaluates the connectivity potential of any building, anywhere, offering four levels of certification and a total scorecard of 120 points. ActiveScore (Travel Facilities) counts for 10 points:
See more information and details at https://modescore.com/

20/04/2026 - Update including BREEAM Residential 6.1

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.