Refurbishment and Fit Out / UK RFO 2014 / 09 - Pollution /

POL 05 - Noise Attenuation

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Achieving a reduction in noise levels where background levels are low - KBCN1692

Where existing background levels are low, such as during night-time, there is no dispensation or flexibility that can be applied in achieving the requirements.  The aim of the issue is to reduce the potential impact of noise from the assessed building to local noise-sensitive buildings.  Acoustic experts have confirmed that the requirements for the background noise levels are still appropriate where existing levels are low, including where a 5dB reduction is stated within the criteria.

Campus with multiple building assessments - KBCN0597

If a campus development project has multiple building assessments being built in conjunction with each other, each building should be assessed independently.  Where there are noise sensitive buildings; including any new buildings in the process of being built, the criteria requirements must still be met.

Compliant attenuated noise levels - KBCN00047

BS 4142 noise level requirements can be used to demonstrate compliance provided the best practice testing methodologies for noise attenuation outlined in BS 7445 are followed.    

Existing plant – Noise impact assessment - KBCN0640

The existing background noise level should not include existing plant associated with the assessed building (criterion 2.a.i). Both existing and newly specified externally mounted plant should be considered within the noise impact assessment as part of the ‘rating noise level’ (criterion 2.a.ii). However, for Part 2 only and Part 3 only assessments, as indicated in the relevant CNs within the manual, only the noise impact of existing or new externally mounted plant specified within the scope of that Part is to be considered. For example, in a Part 3 only assessment, where existing plant forms part of the core services and new plant is installed as part of the local services, only the impact of the noise generated by the new plant should be considered. The existing plant noise should be included as part of the existing background levels. Issue Pol 05 assesses the impact of existing and newly specified externally mounted plant and the impact of any fabric measures on reducing the impact of noise on any nearby noise-sensitive buildings. Its applicability is relevant to all treated buildings where Part 1 is included, even where the existing plant is not being upgraded and is scope dependent when Part 2 or Part 3 only assessments are carried out.
13.08.18 KBCN content amended to include consideration of Part 2 or Part 3 only assessments.
This will be clarified in the next manual re-issue.
03.11.2021 Issue 2.0 of the UK RFO technical manual amended.

Post construction noise level testing - KBCN00043

Noise level measurements do not need to be taken at the post construction stage if the acoustician has accurately modelled the noise level from the plant, using manufacturer's literature, and site measurements taken at the design stage. Any attenuation measures specified by the acoustician in their report must be confirmed as being present post construction. If the acoustician has been unable to model the noise level accurately, post construction measurements are needed to demonstrate compliance. Calculations and recommendations from the acoustician are relied on to be accurate and in keeping with best practice; attenuation measures are assumed to be specified and installed correctly.   

Scope of issue – clarification – fixed installations - KBCN1660

The scope of this issue covers noise from external building services (or 'fixed installations' as written in the manual) serving areas designed for human comfort. The noise impact assessment excludes:

Suitably Qualified Acoustician – Associate membership of the Institute of Acoustics - KBCN00064

Associate membership of the Institute of Acoustics (IOA) can be considered to demonstrate that the individual is a member of an appropriate professional body. This supersedes previous guidance on this matter, which has been updated following confirmation from the IOA that ‘Associate members’ are bound by the same Members’ Code of Conduct as ‘Full members’.    
06/06/2022 - BRE stance on this has been revised - Title also updated for clarity
13/01/2020 Wording clarified and confirmed applicability to Issue Pol 05
06/01/2020 Clarification that this applies to BREEAM UK NC2018
 

Temporary power solutions in noise impact assessments - KBCN0171

Plants such as standby generators that are only used temporarily are excluded from the noise impact assessment.

Verification of measurements undertaken by non-SQA - KBCN1661

It is acceptable for individuals who do not meet the BREEAM definition of a suitably qualified acoustician (SQA) for Pol 05 to undertake the testing for this issue, provided the measurements or calculations are verified by a SQA. The SQA must review the report and confirm in writing that they have found it to:
  1. Represent sound industry practice
  2. Be appropriate given the building being assessed and scope of works proposed
  3. Avoid invalid, biased and exaggerated recommendations
Additionally, written confirmation from the SQA how they comply with the definition of a SQA is required.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.