New Construction / International / V7 /

03 - Energy

Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.

Assessment of multiple buildings within a single BREEAM assessment - KBCN1836

Ene01, Ene02 and Wat01, which use area-weighted performance scales, must be assessed using the methodology set out below where multiple buildings are included within the scope of a single BREEAM assessment, including where: • the Similar Buildings approach is applied, in accordance with Section 4 of GN20; or • Separate buildings with a single overarching function are located on the same site, in accordance with Section 6 of GN20 (e.g. a principal building with one or more ancillary or supporting buildings). Ene01 For UK NC projects, energy models (BRUKL files) must be uploaded for each building included within the assessment. For International NC projects, the assessor must enter floor area-weighted average values for the relevant energy performance metrics for both the actual building(s) and the reference building(s), covering all buildings and applicable building uses included in the assessment. Ene02 All buildings included within the assessment must be modelled in accordance with the methodology. The energy performance score must be calculated using floor area-weighted metrics covering all buildings, and compared against a benchmark derived from a floor area weighted average of all building types included within the assessment. Wat01 For Wat01, the assessor must enter details for all water-using components across all buildings included within the assessment. The Wat01 benchmark is determined using a floor area-weighted occupancy by building type, covering all buildings within scope of the BREEAM assessment.

GN49 International Ene 01 calculation methodology guidance - KBCN1749

Latest version: v0.0, July 2025 Guidance Note 49 (GN49) gives background information on the methodology for determining the number of credits achieved for energy performance under the Ene 01 assessment issue for BREEAM International NC V7. The Ene 01 methodology uses a triple metric approach that addresses energy demand for heating and cooling, primary energy consumption, and carbon dioxide emissions. The aim of using this approach is to minimise the energy consumption and carbon emissions from regulated energy uses and to maximise the use of low carbon energy sources. Guidance Note 49 also includes the adjustment factors that are applied to uplift the reference metrics in Ene 01 for BREEAM International NC V7. It describes the methodology for determining the factors and the application process to have a country’s adjustment factor added or updated. Download Guidance Note 49 View all Guidance Notes on BREEAM Projects (licensed assessors only)

GN53 Energy modelling and predicted operational energy performance score in Ene 02 - KBCN1751

Latest version: v0.2, February 2026 Guidance Note 53 (GN53) provides guidance for the predictive energy modelling and predicted operational energy performance score credits within Ene 02, detailing the input process for the issue’s operational energy calculator. Download Guidance Note 53 View all Guidance Notes on BREEAM Projects (licensed assessors only)
16-Feb-2026 - Updated for release of GN53 0.2

More than one system providing the same building service - KBCN1908

Where different systems provide the same building service to different areas of the building, the characteristics of the system that serves the highest proportion of the building's floor area must be assessed.  For example, if there are two electrical space heating systems serving the same building, only the system supplying the larger floor area must be assessed for compliance.
KBCN Reinstated 24-Sep-2026

Predicted operational energy performance score – Credit table update - KBCN1825

From 4th February 2026, the following credit table applies to Ene 02 in all BREEAM International New Construction V7 and BREEAM UK New Construction V7 assessments: *Alternatively meet the minimum EPRNC score specified for Excellent in Ene 01. **Alternatively meet the minimum EPRNC score specified for Outstanding in Ene 01. The OEPNC scores required for each credit boundary have been lowered on the BREEAM platform in response to assessor feedback and an internal review of credit attainment against our benchmark database. The table above supersedes: - Table 28 in BREEAM International New Construction V7 - Table 6.3 in BREEAM UK New Construction V7 For further guidance on Ene 02 and the achievement of OEPNC scores please refer to KBCN1751 - GN53 Energy modelling and predicted operational energy performance score in Ene 02. The above updated credit table will be included in the next reissue of the technical manuals

Prediction of operational energy and carbon – PHPP - KBCN1915

In applicable scheme versions (please see above), PHPP (Passive House Planning Package) will be considered as a compliant modelling approach for the prediction of operational energy (and carbon). This applies only to homes and small non-domestic buildings, where the building services are limited to: This methodology cannot be used where the building services include central air handling, mechanical cooling, or air conditioning.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.