AI calculation – changes to public transport services during the assessment - KBCN1527

The AI is calculated as part of the design stage transport analysis and its value relates to the site location and to informing transport-related design decisions. This must be based on current information, including any planned and publicly-notified changes at the time the transport assessment is carried out. This should be used as the AI benchmark for the assessment. Where later, unforeseen changes to public transport availability are implemented before post-construction certification, the AI benchmark should not be updated at post-construction stage. Assessments should not be disadvantaged by, or benefit from such changes.

Amenities – Pharmacy within a hospital or health centre - KBCN0321

To meet the requirements of 'Over the counter services associated with a pharmacy', a dispensary within a health centre or hospital can be considered as meeting the intent, provided it is publicly accessible and also offers the type of over-the-counter services associated with a stand-alone pharmacy, such as non-prescription medication and health products. Note: This is a change to the approach outlined in the previous KBCN wording, therefore, for assessments registered before this update, where it can be demonstrated that the the assessor has advised the project team based on the previous wording, this can be accepted: Superseded guidance: A publicly accessible pharmacy would typically be required in order to constitute a suitable amenity. If it can be confirmed that an internal pharmacy (in Northern Ireland this may also include an onsite controlled medical dispensary) will provide prescribed medicines for building users, this is acceptable.
18 June 2025 - Title updated and wording amended to clarify the intent. Applied to NC V6 standards.

Bristol Transport Access Level (BrisTAL) - KBCN1426

BrisTAL is no longer being updated, and the platform may no longer be available. Therefore, the Accessibility Index (AI) output from BrisTAL is no longer compliant with BREEAM. Previously, BrisTAL offered an Accessibility Index (AI) that measures the level of public transport connectivity within the city of Bristol, based on the PTAL method, and could be used as evidence of compliance with the AI for BREEAM. Now, Bristol projects will need to calculate the AI using the BREEAM transport tool.
03 08 2022 - Updated to clarify that the dataset used must be current at the time of the transport assessment, but this does not need to be updated at post-construction stage
03 12 2025 - This route is no longer applicable for assessments registered after this update.

Compliance Note CN3 ‘Cycle route’ clarification - KBCN0845

Shared cyclist routes referred to in Point 3 under CN3 ' Cycle route'  relate to two way low flow cycle routes. Where these are shared with pedestrian routes , a minimum width of 3m is required.  

Cycle spaces – Compliant types of storage - KBCN0257

Due to the number of different types of cycle storage facility available and the variation in site conditions, BREEAM New Construction is less prescriptive about the dimensions and type of cycle parking which can be used to demonstrate compliance. The Assessor is expected to exercise their professional judgement to determine whether the cycle parking spaces meet the aims of the Issue and the requirements listed in the compliance notes. BREEAM is used to certify buildings, not products. Cycle parking systems cannot, therefore, be considered inherently 'BREEAM compliant'. These must be assessed in context with reference to their location and the intended user profile.  
29/01/2024-made applicable to HQM

Cycle spaces – Folding bicycles and scooters - KBCN00024

The provision of cycle storage that is only suitable for folding bicycles or scooters is not compliant. Providing reduced storage space for folding bicycles or scooters in place of compliant cycle storage may limit future travel options.
14 03 2018 Wording clarified and reference to scooters included.

Cycle storage – provided in a garage or shed - KBCN1562

Cycle storage in a garage Where cycle storage is provided in a garage, adequate space must be provided to store both the bicycle(s) and the car(s) at the same time. For double garages, it must be assumed that each garage space is occupied by a car. Storage areas above must be added to the typical minimum garage sizes below: • 2.4 m × 4.9 m for a single garage • 5 m × 5.2 m for a double garage Cycle storage in a shed Where cycle storage is provided in a shed, adequate space must be provided to store both the bicycle(s) and garden tools at the same time. A minimum of 1m2 is required for garden tools. Additional space required for cycles The minimum storage area required to store cycles on the floor, as defined by the New Metric Handbook, which includes space to allow the cycles to be moved independently. Where a proprietary storage or hanging system is provided, the space requirements are flexible but the system must allow each cycle to be removed independently and meet all other criteria.
The technical manual will be updated accordingly at the next re-issue.

Cycle storage spaces – rounding - KBCN1103

The calculation for the required number of cycle spaces must always be rounded up.

Cycle storage within the curtilage of a home - KBCN0830

Where credits for '01 Cycle Storage' are sought and the cycle storage is located within the curtilage of the home, crit 3 does not apply. In the above scenario where credits are also being sought for '02 Cycle Networks', access from the cycle storage to a pedestrian or cycle route is not permitted through the home.  

Dedicated cycle paths in the absence of cycle facilities - KBCN00039

Safe cycle access needs to be provided even if there are no dedicated cycle facilities. The dedicated cycle paths will generally need to be provided to the main entrance(s) of the building along routes likely to be used by cyclists through the site.  The design team are required to determine what is required to satisfy the intent of the criteria. Cycle access and cyclists' facilities are assessed independently of each other. Building users may cycle even if the building does not have cycle storage facilities and so safe and secure access to and from the building must be provided.

Erratum – Accessibility Index – HQM Transport calculator - KBCN1276

The Accessibility Index in the HQM Transport calculator is based on the availability of public transport during peak times only. Wording in the manual should read as follows: Criterion 2.c should read as follows: The average number of services stopping per hour at each compliant node during peak times.  The Methodology for 'Calculating the average number of services' should read as follows: For the purpose of the calculation, the frequency of public transport is the average number of services per hour. This is calculated by determining the number of stopping services at the node during peak times, divided by the number of hours within that period.   

Erratum: ‘Cycle storage requirements’ definition - KBCN1641

There is an error in the dimensions in point 1. 2. and 3 of the 'Cycle storage requirements' definition as follows: The distance between each cycle rack and surrounding obstructions(e.g. walls) allows for bikes to be easily stored and accessed. Cycle racks must be a minimum of: 1. 2m long ×0.75m wide for one bike. 2. 2m long ×1.5m wide for two bikes. 3. 2m long ×2.5m wide for four bikes. Please refer to KBCN0257 instead of the above.

Existing cycle routes - KBCN0828

Where credits for cycle networks are being sought using existing cycle routes then  it must be ensured that these meet the requirements of CN3 'Cycle route'.      

Greater Manchester Accessibility Level (GMAL) - KBCN1394

The Greater Manchester Accessibility Levels (GMAL) method has been created to provide a way of measuring the density of public transport provision at any location within the Greater Manchester region. It is derived from the Public Transport Accessibility Level (PTAL) approach used by Transport for London. As such, the Greater Manchester Accessibility Index (GMAI) scores generated by the GMAL method can be used as evidence of compliance against the BREEAM and HQM Accessibility Index requirements. Please note that project teams must ensure that they use the version of the GMAL dataset that is current at the time the transport assessment is undertaken. This is available from the data.gov.uk website (https://data.gov.uk/dataset/d9dfbf0a-3cd7-4b12-a39f-0ec717423ee4/gm-accessibility-levels-gmal).
02 08 2022 - Updated to clarify that the dataset used must be current at the time of the transport assessment, but this does not need to be updated at post-construction stage

No car parking provisions within the development - KBCN0832

The 'electric charging points' credits cannot be awarded by default where there is no car parking provision within a development. In such scenarios the aim of the issue to promote alternative sustainable transport options and reducing the dependency on traditionally fueled cars, will not be met.

PTAL report supporting evidence - KBCN0230

For developments in Greater London where a Public Transport Accessibility Level (PTAL) report is provided, this report does not need to be supplemented by additional evidence to demonstrate compliance with criteria. The assessor should be satisfied that the PTAL report is current and accurately relates to the assessed site.

Public transport node distance - KBCN1307

There is no defined threshold for relevant public transport nodes, for the purposes of calculating the accessibility index (AI) score in HQM. The HQM Transport Calculator tool gives increasingly more contribution to the AI score, the closer public transport nodes are to the assessed home. The assessor should use their judgement to include public transport nodes that may reasonably be used by occupants, in-practice. This approach is taken in order to recognise the relative value of having access to public transport nodes, even if they are slightly beyond a clear-cut threshold or are well beyond walking distance but still may be used, even if it is to a lesser extent.

Publicly accessible car club - KBCN0836

In general, a publicly accessible car club is considered a compliant solution for meeting crit 7, provided these are accessible to the occupants, are within 650m walking distances from the home via a safe pedestrian route. For confirmation on whether a particular publicly accessible car club solution is acceptable, please contact us.  

Safe pedestrian routes – Definition, measurement and verification - KBCN0238

Definition Safe pedestrian routes include pavements and safe crossing points, which may be controlled or, for example, be identified by tactile paving, a crossing island or a dropped kerb. An element of judgement may be required, in which case justification should be provided. Measurement Distances could be measured, for example, along a pavement, across a road at a safe crossing point and along the pavement on the other side.  The distance should not be measured diagonally across a road, following the most direct route. Verification The assessor’s site inspection is an important aspect of the assessment and may help to confirm that all relevant information is current and can include photographs of any key areas. This can also help to identify safe crossing points or hazards which may not be apparent from a desktop study. Alternatively, web-based map data may be used to satisfy the evidence requirements at both Design and Post-Construction Stage, provided that the assessor is satisfied that this clearly demonstrates compliance and that the evidence is robust and up to date. Where web-based navigation maps (e.g. Google Maps/Street View) are used as evidence, this must include: • Dated and marked-up site plan or a web-based navigation map viewer highlighting: • Current location and type of transport nodes and local amenities. • Current route and distance from the building via a safe pedestrian route. • Plan or map scale. When relying on web-based evidence for post-construction stage, the assessor must, additionally, provide verification that the information provided for the nodes/amenities is still accurate and up to date.  
16 Sep 2025 - Wording relating to verification updated to clarify the intent.
29 Aug 2025 - Approach to web-based map data at post-construction stage updated and related wording amended accordingly
07 Mar 2024 - No changes have been made. This appears as 'updated' due to an administrative error.
11 Jan 2024 - Wording re-structured for clarity
19 Dec 2023 - Applicability to BIU V6 confirmed

Shared cycle storage between two apartment blocks - KBCN1323

In principle, it is possible for cycle spaces within two or more separate buildings (e.g. apartment blocks) can be shared for the purposes of adequate cycle storage if the following can be assured:

Please note that these scenarios need to be assessed on a case by case basis. Please raise a technical query with details and plans that demonstrate how the above points have been addressed, for further consideration.

The distance of the cycle route from the cycle storage - KBCN0826

There is currently no set requirement in the HQM technical manual with regards to the distance the cycle route must be from the cycle storage. The HQM assessor should use their discretion to decide whether the distance in their specific scenario is acceptable.  