UKNC: Residential (HQM) / HQM beta / A Our Surroundings / A1 Transport and Movement /
02 Alternative Sustainable Transport Options
Information correct as of 23rdNovember 2026. Please see kb.breeam.com for the latest compliance information.
Compliance Note CN3 ‘Cycle route’ clarification - KBCN0845
Shared cyclist routes referred to in Point 3 under CN3 ' Cycle route' relate to two way low flow cycle routes.
Where these are shared with pedestrian routes , a minimum width of 3m is required.
Cycle spaces – Compliant types of storage - KBCN0257
Due to the number of different types of cycle storage facility available and the variation in site conditions, BREEAM New Construction is less prescriptive about the dimensions and type of cycle parking which can be used to demonstrate compliance. The Assessor is expected to exercise their professional judgement to determine whether the cycle parking spaces meet the aims of the Issue and the requirements listed in the compliance notes.
BREEAM is used to certify buildings, not products. Cycle parking systems cannot, therefore, be considered inherently 'BREEAM compliant'. These must be assessed in context with reference to their location and the intended user profile.
29/01/2024-made applicable to HQM
Cycle spaces – Folding bicycles and scooters - KBCN00024
The provision of cycle storage that is only suitable for folding bicycles or scooters is not compliant.
Providing reduced storage space for folding bicycles or scooters in place of compliant cycle storage may limit future travel options.
14 03 2018 Wording clarified and reference to scooters included.
Cycle storage – provided in a garage or shed - KBCN1562
Cycle storage in a garage
Where cycle storage is provided in a garage, adequate space must be provided to store both the bicycle(s) and the car(s) at the same time.
For double garages, it must be assumed that each garage space is occupied by a car. Storage areas above must be added to the typical minimum garage sizes below:
• 2.4 m × 4.9 m for a single garage
• 5 m × 5.2 m for a double garage
Cycle storage in a shed
Where cycle storage is provided in a shed, adequate space must be provided to store both the bicycle(s) and garden tools at the same time. A minimum of 1m2 is required for garden tools.
Additional space required for cycles
The minimum storage area required to store cycles on the floor, as defined by the New Metric Handbook, which includes space to allow the cycles to be moved independently.
Where a proprietary storage or hanging system is provided, the space requirements are flexible but the system must allow each cycle to be removed independently and meet all other criteria.
The technical manual will be updated accordingly at the next re-issue.
Cycle storage spaces – rounding - KBCN1103
The calculation for the required number of cycle spaces must always be rounded up.
Cycle storage within the curtilage of a home - KBCN0830
Where credits for '01 Cycle Storage' are sought and the cycle storage is located within the curtilage of the home, crit 3 does not apply.
In the above scenario where credits are also being sought for '02 Cycle Networks', access from the cycle storage to a pedestrian or cycle route is not permitted through the home.
Dedicated cycle paths in the absence of cycle facilities - KBCN00039
Safe cycle access needs to be provided even if there are no dedicated cycle facilities. The dedicated cycle paths will generally need to be provided to the main entrance(s) of the building along routes likely to be used by cyclists through the site. The design team are required to determine what is required to satisfy the intent of the criteria.
Cycle access and cyclists' facilities are assessed independently of each other. Building users may cycle even if the building does not have cycle storage facilities and so safe and secure access to and from the building must be provided.
Erratum: ‘Cycle storage requirements’ definition - KBCN1641
There is an error in the dimensions in point 1. 2. and 3 of the 'Cycle storage requirements' definition as follows:
The distance between each cycle rack and surrounding obstructions(e.g. walls) allows for bikes to be easily stored and accessed.
Cycle racks must be a minimum of:
1. 2m long ×0.75m wide for one bike.
2. 2m long ×1.5m wide for two bikes.
3. 2m long ×2.5m wide for four bikes.
Please refer to KBCN0257 instead of the above.
Existing cycle routes - KBCN0828
Where credits for cycle networks are being sought using existing cycle routes then it must be ensured that these meet the requirements of CN3 'Cycle route'.
No car parking provisions within the development - KBCN0832
The 'electric charging points' credits cannot be awarded by default where there is no car parking provision within a development.
In such scenarios the aim of the issue to promote alternative sustainable transport options and reducing the dependency on traditionally fueled cars, will not be met.
Publicly accessible car club - KBCN0836
In general, a publicly accessible car club is considered a compliant solution for meeting crit 7, provided these are accessible to the occupants, are within 650m walking distances from the home via a safe pedestrian route.
For confirmation on whether a particular publicly accessible car club solution is acceptable, please contact us.
Safe pedestrian routes – Definition, measurement and verification - KBCN0238
Definition
Safe pedestrian routes include pavements and safe crossing points, which may be controlled or, for example, be identified by tactile paving, a crossing island or a dropped kerb. An element of judgement may be required, in which case justification should be provided.
Measurement
Distances could be measured, for example, along a pavement, across a road at a safe crossing point and along the pavement on the other side. The distance should not be measured diagonally across a road, following the most direct route.
Verification
The assessor’s site inspection is an important aspect of the assessment and may help to confirm that all relevant information is current and can include photographs of any key areas. This can also help to identify safe crossing points or hazards which may not be apparent from a desktop study. Alternatively, web-based map data may be used to satisfy the evidence requirements at both Design and Post-Construction Stage, provided that the assessor is satisfied that this clearly demonstrates compliance and that the evidence is robust and up to date.
Where web-based navigation maps (e.g. Google Maps/Street View) are used as evidence, this must include:
• Dated and marked-up site plan or a web-based navigation map viewer highlighting:
• Current location and type of transport nodes and local amenities.
• Current route and distance from the building via a safe pedestrian route.
• Plan or map scale.
When relying on web-based evidence for post-construction stage, the assessor must, additionally, provide verification that the information provided for the nodes/amenities is still accurate and up to date.
16 Sep 2025 - Wording relating to verification updated to clarify the intent.
29 Aug 2025 - Approach to web-based map data at post-construction stage updated and related wording amended accordingly
07 Mar 2024 - No changes have been made. This appears as 'updated' due to an administrative error.
11 Jan 2024 - Wording re-structured for clarity
19 Dec 2023 - Applicability to BIU V6 confirmed
Shared cycle storage between two apartment blocks - KBCN1323
In principle, it is possible for cycle spaces within two or more separate buildings (e.g. apartment blocks) can be shared for the purposes of adequate cycle storage if the following can be assured:
- if it is being assumed that cycle spaces within one block will be used by occupants from another, these spaces must be clearly dedicated to these occupants only, and this needs to be clearly communicated (e.g. signage)
- All cycle spaces must be within a close proximity (see definition) to the home or communal entrance and are accessible via a safe pedestrian route.
Please note that these scenarios need to be assessed on a case by case basis. Please raise a technical query with details and plans that demonstrate how the above points have been addressed, for further consideration.
The distance of the cycle route from the cycle storage - KBCN0826
There is currently no set requirement in the HQM technical manual with regards to the distance the cycle route must be from the cycle storage. The HQM assessor should use their discretion to decide whether the distance in their specific scenario is acceptable.
Information correct as of 23rdNovember 2026. Please see kb.breeam.com for the latest compliance information.