Refurbishment and Fit Out / RFO Commercial V7 / 01 - Management /

Man 02 - Life cycle cost and service life planning

Information correct as of 12thNovember 2026. Please see kb.breeam.com for the latest compliance information.

Capital cost reporting and LCC measured area - KBCN0438

When assessing the Capital cost reporting and the LCC credits, the area to be considered should be the Gross Internal Floor Area (GIFA), according to the below RICS definition: Gross Internal Floor Area Gross Internal Floor Area is the area of a building measured to the internal face of the perimeter walls at each floor level, which includes: And excludes:
14.02.18 - KBCN content amended to extend the applicability to LCC and to refer to GIFA rather than GEA, to reflect current industry practice.

Elemental LCC and options appraisal timing - KBCN1889

The elemental LCC should be undertaken as part of the strategic options appraisal process and used to inform the selection of significant building elements and systems, such as the structure, envelope and building services. Completing the options appraisal after key design decisions have been finalised may reduce its effectiveness and limit the opportunity for the findings to influence the final design. However, the timing requirement can still be met, where the assessor agrees that there is a justification for the appraisal continuing into early AIA Stage 2 - Schematic Design (or equivalent), and clear evidence to demonstrate that: In all cases, the outline elemental LCC plan and identification of relevant project options must be completed by the end of Concept Design
Information correct as of 12thNovember 2026. Please see kb.breeam.com for the latest compliance information.