Refurbishment and Fit Out / International RFO 2015 / 04 - Transport /
TRA 04 - Maximum Car Parking Capacity
Information correct as of 9thNovember 2026. Please see kb.breeam.com for the latest compliance information.
ModeScore Sustainable Transport certification - KBCN1705
Achieving
ModeScore Gold or Platinum certification may be used as supporting evidence
to award credits for the Transport issues listed in the table below. This alignment is permitted
provided that the BREEAM technical criteria are demonstrably met.
| Scheme |
Issues |
Credits Achievable via ModeScore |
| BREEAM International NC 2016 and V6 |
Tra 03a Alternative modes of transport |
2 + Exemplary credit |
| Tra 03b Alternative modes of transport |
2 + Exemplary credit |
| Tra 04 Maximum car parking capacity |
1 |
| BREEAM UK NC 2018 and V6 * |
Tra 02 Sustainable transport measures |
10 |
| BREEAM Int RFO 2015 |
Tra 01 Sustainable transport solutions |
5 |
| Tra 04 Maximum car parking capacity |
2 |
| BREEAM UK RFO 2014 |
Tra 01 Sustainable transport solutions |
3 |
| Tra 03 Cyclist facilities |
2 |
| Tra 04 Maximum car parking capacity |
2 |
| BREEAM In Use Commercial and Residential (International and USA) |
Tra 01 Alternative modes of transport |
8 |
| Tra 02 Proximity to public transport |
3 |
| Tra 04 Pedestrian and cyclist safety |
2 |
| BREEAM UK NC Residential V6.1* |
1.1 Public transport availability |
3 |
| 1.2 Sustainable transport options |
17 |
Evidence Requirements
To award credits using this route, the Assessor must:
- Submit the ModeScore Certification and Assessment Report.
- Provide a mapping statement demonstrating how the targeted BREEAM criteria have been met using the relevant ModeScore criteria.
- Provide any Supplementary Evidence identified through the mapping process.
Scheme-Specific Provisions*
- BREEAM UK New Construction (2018 & V6) – Tra 02
Credits may be awarded provided the prerequisite for a Transportation Assessment and Travel Plan (Criterion 1) has been met.
- BREEAM UK New Construction Residential V6.1 Issue 1.2
Credits may be awarded provided the prerequisite for Home Information (Criterion 1) has been met.
About ModeScore Sustainable Transport certification:
ModeScore assess and certifies sustainable transport facilities and services in buildings. ModeScore encompasses ActiveScore within its assessment criteria, covering four pillars of sustainable transportation while incorporating accessibility into each:
- Public Transportation
- Environmentally-Friendly Private Vehicles
- Active Transportation
- Site-Wide Mobility
ModeScore evaluates the connectivity potential of any building, anywhere, offering four levels of certification and a total scorecard of 120 points. ActiveScore (Travel Facilities) counts for 10 points:
- Certified (0-39%)
- Silver (40-59%)
- Gold (60-79%)
- Platinum (80-100%)
See more information and details at https://modescore.com/
20/04/2026 - Update including BREEAM Residential 6.1
No car parking provision - KBCN00059
Where the assessment criteria are applicable to a building that has no car parking spaces and where there are no parking spaces accessible to building users, the benchmarks can be considered to be met. If, however, parking is shared with other buildings or parking spaces are available on a campus-type site then the provision must still be assessed.
Obligation to provide a minimum number of car parking spaces exceeding BREEAM requirements - KBCN0401
Where it can be demonstrated (by documentary evidence) an obligation to meet a ’minimum car parking requirement’ which exceeds the BREEAM benchmarks is imposed by the planning authority, as long as no more than the stipulated minimum spaces are provided, a single credit can be awarded.
Occupancy calculation – Buildings with shift patterns - KBCN0431
In buildings with shift patterns, as shifts may overlap, the building users calculation should be based on the maximum occupancy of the building at any given time.
Parking integral to development’s use - KBCN1145
Dedicated on-site parking which is integral to the function of the development can be excluded from the calculation of parking capacity. Examples could include, but are not limited to:
- Dedicated bays for police vehicles at a police station
- Parking for delivery vehicles at an industrial warehouse
- Holding bays for damaged vehicles at a vehicle repair centre
The spaces are only to be used for this purpose, and must have appropriate signage and / or markings.
Parking spaces with electric car recharging stations - KBCN00044
Electric car spaces should be included in the total number of car parking spaces calculation for maximum car parking capacity.
Whilst electric cars provide benefits in terms of reduced emissions, they do not directly reduce congestion which is one of the aims of this issue.
Public car parks - KBCN00092
Any public car parks in the vicinity of the assessed building, for which the building owners/operator are not providing some form of subsidy or an agreement with the car park operators to provide priority spaces for building staff, can be excluded from the assessment.
Rounding the number of parking spaces - KBCN0602
Where the calculated number of car parking spaces is a fraction of a whole number, this should be rounded down to the next whole number to assess the issue.
Fewer parking spaces are preferable as the more sustainable solution.
Temporary Car Parking - KBCN0751
The number of car parking spaces should be based on the permanent parking spaces provided specifically for the development once fully operational.
Assessors should determine whether parking spaces should be considered 'permanent' or 'temporary', based on evidence provided by the design team.
Visitor car parking spaces for Other Buildings (Transport type 2) - KBCN0242
For developments such as hotels and visitor centres, which have a relatively small number of staff and large visitor numbers, the guest/visitor car parking spaces do not need to be assessed for this Issue where these are separate from the staff parking spaces. However, if the staff and visitor’s spaces are combined (and not clearly segregated) then all spaces must be accounted for within the calculation for maximum car parking capacity.
The aim of this Issue, 'To encourage the use of alternative means of transport...' is intended to apply to those commuting to the building on a regular basis.
21 06 2017 Wording amended to clarify the type of building and building-user covered by this KBCN.
Information correct as of 9thNovember 2026. Please see kb.breeam.com for the latest compliance information.