New Construction / International / 2013 / 04 - Transport /
Tra 03b - Alternative Modes of Transport (residential)
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.
Cycle spaces – Compliant types of storage - KBCN0257
Due to the number of different types of cycle storage facility available and the variation in site conditions, BREEAM New Construction is less prescriptive about the dimensions and type of cycle parking which can be used to demonstrate compliance. The Assessor is expected to exercise their professional judgement to determine whether the cycle parking spaces meet the aims of the Issue and the requirements listed in the compliance notes.
BREEAM is used to certify buildings, not products. Cycle parking systems cannot, therefore, be considered inherently 'BREEAM compliant'. These must be assessed in context with reference to their location and the intended user profile.
29/01/2024-made applicable to HQM
Cycle spaces and facilities – Rounding calculations - KBCN0445
The calculation for the required cycle spaces and facilities must always be rounded up. If the calculation works out as 5.3 cycle spaces, 6 cycle spaces must be provided.
To determine the requirements for developments with multiple types of building user, calculate the requirement for each user group separately (rounding up to the determine the number of spaces) and then add the number of cycle spaces for each user group together.
04/10/2018 Wording amended to clarify the correct calculation method for developments with multiple user groups.
Electric vehicle (re)charging stations/points/spaces - KBCN0934
For BREEAM purposes, a vehicle charging station/space includes a facility that is dedicated to charging vehicles. Provision of a mains-powered electrical socket will not be deemed compliant.
13 October 2023 - Title and wording updated to align with terminology used elsewhere in our guidance.
Electric Vehicle Charging Spaces (EVCS) – Limited parking - KBCN1403
The criteria for Option 3 are based on the number and size of dwellings. It has been recognised, however, that for many developments, where the number of car parking spaces provided is limited, this may not be appropriate.
The criteria for this option will be fully reviewed for the forthcoming scheme update, however in the meantime, the following clarifications can be applied.
In order to ensure that provision is available to occupants according to nature of the development and the type of parking arrangement, the requirements are set out as below. For communal parking, accounting for the expected increase in uptake of PEVs (Plug-In Electric Vehicle), whilst mindful of the useful service life of EV charging equipment, the number of fully-functional EVCS required for compliance has been reduced.
Individual dwellings with private parking spaces within the curtilage of the property
The current criteria apply, as per Table 32 (NC2013) and Table 35 (NC2016).
In instances where it can be demonstrated that the total number of parking spaces for the dwelling is less than the number of EVCS required by the criteria, two credits can be awarded where all parking spaces provided are fully functional EVCS.
Developments with communal parking areas
1 Credit – Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces, (including visitor spaces, where provided), of which at least 25% are fully functional.
2 Credits - Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces (including visitor spaces, where provided), of which at least 50% are fully functional EVCS.
Where on-site parking provision includes special user-groups, such as disabled, car share, car pool or visitors only, compliance can be met where the required percentage of EVCS is provided for those users on a pro-rata basis, with a minimum of one EVCS, per user-group provided for on site.
Where on-site parking provision is limited to such special user-groups only, compliance can be met where the required percentage of EVCS is provided for those users (up to a maximum of providing EVCS for all spaces), with a minimum of one EVCS, per user-group provided for on site.
Partially-fitted assessments
2 Credits - Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces, (including visitor spaces, where provided). This clarifies the guidance previously provided in KBCN1247.
Note
In all cases, the above clarifications do not seek to impose more onerous requirements than those specified in the technical guidance.
Electric vehicle charging stations - KBCN0684
As per the 'Alternative transport measures' criteria, the percentage requirement for electric charging stations should be based on the total car parking capacity for the building.
Where the assessment covers only part of a building or development this must be based on the total car parking capacity unless the parking for the assessed development is clearly segregated and available only for the use of its building users.
23 03 17 Reference to car sharing spaces removed. See also KBCN0282
Electric vehicle charging stations – Requirement to demonstrate that electric vehicles have lower CO2 emissions - KBCN1622
This requirement is now considered obsolete and it is no longer a requirement where compliant electric vehicle charging points are installed.
Electric vehicle charging stations – shell & core assessments - KBCN1247
For BREEAM NC shell only/shell & core, RFO Parts 1 and 2 only and partially-fitted residential assessments, compliance can be demonstrated by installing all the necessary infrastructure, (i.e. capacity in the connection to the local electricity distribution network and distribution board, as well as sub-surface ductwork to receive cabling to parking spaces), to enable the simple installation and activation of charging points at a future date.
18/10/2021 Applicability to BREEAM Scheme and Assessment Type clarified, in line with the intent.
15/11/2019 Incorrect reference to pre-installation of 'cabling' removed.
Exemplary level criteria – option 5 - KBCN0529
In order to use option 5 to achieve the Exemplary level credit, two credits must be achieved in this option.
On-demand public bus services - KBCN1404
These can be recognised as follows:
- The location of the transport node should be determined as the nearest available pick-up point to the assessed building
- The frequency of the service should be considered as the published maximum wait time (or actual average wait time, if the service is established and this data is available)
- Such services, whilst they may serve multiple destinations, should be considered as a single route
- It must be demonstrated that information on the availability and how to access the service is made available to building users
This is limited to genuine on-demand bus services, which are operated as public transport with multiple pick-up and drop-off points and does not extend to private hire, taxi or other similar operations.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.