Option 3 – Electric Vehicle Charging Spaces (EVCS)

The criteria for Option 3 are based on the number and size of dwellings. It has been recognised, however, that for many developments, where the number of car parking spaces provided is limited, this may not be appropriate.
The criteria for this option will be fully reviewed for the forthcoming scheme update, however in the meantime, the following clarifications can be applied.
In order to ensure that provision is available to occupants according to nature of the development and the type of parking arrangement, the requirements are set out as below. For communal parking, accounting for the expected increase in uptake of PEVs (Plug-In Electric Vehicle), whilst mindful of the useful service life of EV charging equipment, the number of fully-functional EVCS required for compliance has been reduced.

Individual dwellings with private parking spaces within the curtilage of the property
The current criteria apply, as per Table 32 (NC2013) and Table 35 (NC2016).
In instances where it can be demonstrated that the total number of parking spaces for the dwelling is less than the number of EVCS required by the criteria, two credits can be awarded where all parking spaces provided are fully functional EVCS.

Developments with communal parking areas
1 Credit – Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces, (including visitor spaces, where provided), of which at least 25% are fully functional.
2 Credits – Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces (including visitor spaces, where provided), of which at least 50% are fully functional EVCS.

Where on-site parking provision includes special user-groups, such as disabled, car share, car pool or visitors only, compliance can be met where the required percentage of EVCS is provided for those users on a pro-rata basis, with a minimum of one EVCS, per user-group provided for on site.

Where on-site parking provision is limited to such special user-groups only, compliance can be met where the required percentage of EVCS is provided for those users (up to a maximum of providing EVCS for all spaces), with a minimum of one EVCS, per user-group provided for on site.

Partially-fitted assessments
2 Credits – Compliance can be demonstrated by installing all the necessary infrastructure to all car parking spaces, (including visitor spaces, where provided). This clarifies the guidance previously provided in KBCN1247.

Note
In all cases, the above clarifications do not seek to impose more onerous requirements than those specified in the technical guidance.