UKNC: Residential (HQM) / HQM ONE / A Our Surroundings / 2 Outdoors /
2.2 Managing Impacts on Ecology
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.
Assessing ecology issues using a mix of routes - KBCN1306
Where Route 1 is pursued initially and it is subsequently decided that Route 2 should be followed, the Suitably Qualified Ecologist appointed should review all evidence available for the issues already assessed to confirm the actions taken were appropriate.
Note: Route 1 and Route 2 are referred to as the 'Foundation' and 'Comprehensive' routes in HQM and UK NCR.
30-Oct-2025 - Title updated. Applicable to HQM V6 and UKNCR V6.1
Ecology dependency diagrams - KBCN1456
These dependency diagrams show how ecology prerequisites and credits interact across issues in the ecology category.
UK New Construction
UK NC ecology dependencies rev 0.0
Applies to:
Home Quality Mark
HQM V6 ecology dependencies rev 0.0
Applies to:
30-Aug-2023 - HQM ecology dependency diagram added. Title and scheme applicability updated.
Recognised local ecological expertise - KBCN1193
Organisations/individuals that have the expertise to provide specialist input or guidance to inform the adoption of locally relevant (within the zone of influence) ecological measures that enhance the ecological value of the site. This may include bodies such as:
a. Local Government and other statutory relevant organisations.
b. Local community groups, organisations, or charities, such as the Wildlife Trusts.
c. Local, regional, or national fauna focused groups such as Bug life, RSPB, Bat Conservation Trust etc.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
This definition will be added to the relevant technical manuals in their next re-issue.
Relating green roofs to multiple assessments in the same building - KBCN1195
A green roof on top of such buildings can be used to award credits for each assessment for which the Land use and ecology Issues apply. The benefit can be applied to to all assessments undertaken for the building provided all are completed within the appropriate time-frame of a valid ecological survey.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
Site wide approach to ecological enhancements - KBCN1194
A site-wide approach to ecological enhancements can be used on sites where multiple buildings share areas of soft landscaping. The enhancement benefits are applied to the individual building assessments within the site. The benefit can be applied on a site-wide basis provided all developments are completed within the appropriate timeframe of a valid ecological survey.
16-Apr-2026 - Applicable to NC V7
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
Verification of an ecology report / information - KBCN1192
If the appointed ecologist does not meet the definition of a ‘suitably qualified ecologist’ (SQE) the report / information submitted to support the assessment must be verified by an individual who does.
1. The individual verifying the report must provide written confirmation that they comply with the definition of a ‘suitably qualified ecologist’.
2. The verifier must provide
signed confirmation that they have checked and approved the report. This must clearly reference the report and can be in the form of a signed letter or their printed name and signature on a completed pro-forma. In doing so, they are deemed to confirm that the report:
a. represents sound industry practice
b. is correctly, truthful, and objective
c. is appropriate given the local site conditions and scope of works proposed
d. avoids invalid, biased, or exaggerated statements
Such confirmation from the verifier must be provided in addition to all other information required by the relevant technical manual and referenced as part of the evidence submitted to demonstrate compliance.
It can take a number of years for an ecologist to meet the SQE definition. Verification of information by an existing SQE supports the practical application of the assessment criteria and is in line with industry practice.
30-Oct-2025 - Applicable to HQM One, HQM V6 and UKNCR V6.1
13-Aug-2019 Updated to clarify, in practical terms, what evidence of verification will be considered acceptable.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.