In-Use / BIU International Commercial V6 / Part 1 / 01 - Health and wellbeing /
HEA 04 - Lighting control
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.
Applicability – no occupied spaces - KBCN1551
Principle
Where:
- The scope of assessment covers no occupied spaces and,
- There is no valid way to filter credits from that issue,
Credits specifically related to occupied space are not awarded.
Outcome
The tables below show how this principle applies to affected issues.
- Y means all credits are available (unless the comments state otherwise).
Standard filtering rules still apply, so some credits can be filtered out where allowed in the criteria.
- N means all credits in the issue cannot be awarded.
These credits are not filtered out.
| Issue |
Credits available |
Scope |
| Part 1 |
|
|
|
| Hea 01 Daylighting |
Y |
|
Only answer C is available. |
| Hea 02 Control of glare from sunlight |
|
N |
|
| Hea 03 Internal and external lighting levels |
|
N |
|
| Hea 04 Lighting control |
|
N |
|
| Hea 05 Minimising flicker from lighting systems |
Y |
|
|
| Hea 06 View out |
|
N |
|
| Hea 07 User comfort control |
|
N |
|
| Hea 08 |
Y |
|
|
| Hea 09 |
|
N |
|
| Hea 10-13 |
Y |
|
|
| Part 2 |
|
|
|
| Hea 14 Thermal comfort |
|
N |
|
| Hea 15 Smoking policy |
Y |
|
|
| Hea 16 Indoor air quality management |
Y |
|
|
| Hea 17 Acoustic conditions |
|
N |
|
| Hea 18 Legionella risk management |
Y |
|
|
| Hea 19 Drinking water management |
Y |
|
|
16-Jul-2026 - Hea 09 corrected.
16-Dec-2022 - KBCN title and scope updated for better visibility. Error in Hea 03 amended. Applicability of KBCN applied only to affected issues (N, or modified answer options) with to minimise header space in the UI. Original content on Resources moved to new KBCN.
27-Nov-2025 - KBCN applicability updated to include all Hea credit issues.
Zoning and occupant control – access to lighting controls - KBCN00032
The relevant areas for the criteria apply only to areas where users are expected to have control.
For instance, this means that areas intended for the general public, or a shop floor would not be expected to have lighting controls.
The general principle which applies to user access to general environmental controls (heating, cooling, ventilation) may also apply to access to lighting controls. See
KBCN0170.
However, the the exact approach may differ between the two types of systems and assessor judgement must be used to determine compliance.
In all cases zoning is required in all areas of the asset where specified in the assessment criteria. Please refer to the specific requirements of the applicable BREEAM standard to interpret this guidance appropriately.
14-Dec-2022 - KBCN applicability updated to include BIU. Wording updated. Link to KBCN0170 created.
Zoning and occupant control – PIR detection systems - KBCN0335
The aim of the Health & Wellbeing category is to recognise ways to benefit occupants through giving them control of their lighting environment. Without manual overrides, presence or absence detection lighting controls (such as PIR detection systems) are not compliant with the criteria.
BREEAM recognises the energy efficiency benefits of detection systems in buildings through the Energy category. In some cases, the design team may have to prioritise one particular lighting strategy to the detriment of achieving a credit elsewhere.
17 09 2024 Updated to apply to BIU Part 1 - Lighting Controls
28 04 2021 Wording amended to include absence detection systems.
18 09 2017 Wording amended to clarify the meaning.
Zoning and occupant control – whiteboards and display screens - KBCN1433
Whiteboards and display screens in dedicated teaching or presentation spaces require separate zoning and control for lighting, as specified in the criteria.
Lighting around whiteboards and display screens which are typically found in general office areas, meeting rooms, or in other generic spaces do not require separate zoning and control to meet the criteria. In such cases, the assessor should provide justification.
Whiteboards and display screens in dedicated teaching / presentation spaces are likely to be used frequently, and require appropriate zoning and control. An increasing number of offices and meeting rooms now include display screens - however separate zoning and control may not be appropriate.
Information correct as of 19thOctober 2026. Please see kb.breeam.com for the latest compliance information.