Accuracy of life cycle cost projections - KBCN1295
The aim of LCC credits is to encourage homebuilders into identifying enhanced and value-added design and specification to improve the overall quality of the building stock. The design appraisals can help improve upon the design and specification selection should initial projections be too high. HQM LCC credits are not intended to be used for comparison between developments, given the differences in assumptions made in each appraisal. With the introduction of this credit into the HQM, it is expected that projections on durability of elements/ components and forecast for maintenance and operation will improve industry knowledge. This will also encourage transparency in the industry and this credit aims to encourage knowledge-transfer of best practice.
Approved software XML outputs - KBCN0848
Some technical issues within HQM require files from external software to be uploaded to BREEAM Projects in order to generate credits.
These files are only valid where they have been produced using software that has been approved by BRE Global. Please visit Greenbook Live or contact the technical team for information on approved software.
Where a required software is not listed as approved , the software provider would need to gain approved status from BRE Global before it can be used to assess an HQM registered project.
Assessing the roof of a car park that forms the ground floor of the assessed building - KBCN00080
The ground floor of the building above the car park should be assessed as an 'upper floor slab'.
For the purposes of Mat 01 the ground floor slab, which is not assessed, is considered to be the floor which is in contact with the ground.
HQM - Applies to HQM's Environmental Impact from Construction Products assessment issue.
Bamboo, cork and other non-timber forest products – Responsible sourcing - KBCN1768
Non-timber forest products, such as bamboo and cork should be responsibly sourced to minimise the environmental impacts and protect local ecosystems. However, as they are not timber or timber-based products, these fall outside the scope of the Prerequisite.
Where such products are integrated into a building, they should, nonetheless, be assessed and included in the calculator under ‘Other materials’.
Broken chain of custody for legally harvested timber - KBCN1321
The Government website referred to in the ‘Legally harvested and traded timber’ definition in the Responsible sourcing issue, provides the necessary guidance for demonstrating compliance with the prerequisite for this issue, which follows the Central Point of Expertise on Timber (CPET) report on the UK Government Timber Procurement Policy.
The ‘Timber Procurement Advice Note (TPAN)’ provides a checklist (Annex E) for evidence of certified timber (category A evidence). You can find this here:
https://www.gov.uk/government/publications/timber-procurement-advice-note-tpan-comply-with-tpp Annex F of this document gives further guidance if the supplier isn’t directly certified and there is a broken chain of custody. It notes that ‘
As soon as ownership of products is taken by a non-CoC-certificate holder, the products cease to be 'certified'. However, if the evidence is credible, you can make a claim of legal or sustainably sourced products.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
Design stage evidence – Responsible sourcing of construction products - KBCN0831
At design stage, a letter of commitment from the design team confirming that the products shall be procured from suppliers capable of supplying products covered by the required responsible sourcing certification scheme is acceptable. The letter must confirm the responsible sourcing certification schemes of the proposed products.
30-Oct-2025 - Applicable to HQM One, HQM V6 and UKNCR V6.1
Early product procurement policy - KBCN1309
A documented product procurement policy and procedure needs to be in place by RIBA stage 2, which sets out the requirements for all suppliers and trades to adhere to in relation to responsible sourcing of products. However, this policy and procedure can be fairly high-level at RIBA stage 2, as long as all other criteria are met, including dissemination and the encouragement of products that have responsible sourcing certification over products that don’t.
At this early stage, the policy is likely to contain overarching principles and policies that later feed into a more detailed plan or strategy, further into the design stage. BS8903:2010 and BS8900-1:2013, provide guidance on what is considered good practice.
Our experience with BREEAM has shown that considering the potential for responsibly sourced products early on makes procurement of these products more achievable, which in turn makes the associated credits for this more likely to achieve. This principal extends to the other issues in the Materials category as well.
30-Oct-2025 - Applicable to HQM One, HQM V6 and UKNCR V6.1
Evidence requirements – responsible sourcing of materials at post-construction - KBCN1599
Whilst the UK BREEAM manuals are less prescriptive in the evidential requirements to allow flexibility, to ensure consistency across the schemes, it is expected that robust evidence should be provided to verify the source of any certified materials and how the assessor has confirmed the products and manufacturers used.
Evidence supplied at post construction stage must reflect the completed building and confirm the responsibly sourced materials that have been procured and installed on the project. Supporting documentation is required to validate letters of confirmation or schedules of materials.
Evidence provided could include proof of purchase, for example, invoices, delivery tickets, purchase orders or correspondence from suppliers. This may be an example for each material sourced, rather than every delivery ticket for instance. Alternatively, evidence of the use of the responsibly sourced materials may include as-built drawings, O&M documentation or site photographs.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
FSC and PEFC Mixed Sources certified timber - KBCN00091
Products labelled:
- FSC Mix or
- PEFC Mixed Sources
Meet the BREEAM responsible sourcing requirements. This means any such products:
- In HQM, and in BREEAM NC 2016 or older schemes: meet the prerequisite for legally harvested and traded timber.
- In BREEAM NC 2018 or newer schemes: meet the prerequisite for legal and sustainable timber.
- In all schemes: can be used to demonstrate responsible sourcing.
Products carrying the FSC Mix label contain at least 70% FSC certified and recycled material. These products may contain a small proportion of FSC Controlled Wood (KBCN00054). However for BREEAM compliance, the FSC Mix label is sufficient to meet our requirements.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
14-Mar-2024 - Wording clarified and expanded. Relevant prerequisites and requirements clarified. Scheme applicability updated.
FSC Controlled Wood - KBCN00054
The
FSC Controlled Wood label minimises the risk that wood comes from illegal or controversial sources, however it does not eliminate this risk.
Therefore, products which are:
- Labelled as FSC Controlled Wood or,
- Where the majority of material in a product is comprised of FSC Controlled Wood,
Do not meet the BREEAM definition of responsibly sourced.
Where FSC Mix labelled products contain FSC Controlled Wood, see KBCN00091.
This means that any such products:
- In HQM, and in BREEAM NC 2016 or older schemes: do not meet the prerequisite for legally harvested and traded timber.
- In BREEAM NC 2018 or newer schemes: do not meet the prerequisite for legal and sustainable timber.
- In all schemes: cannot be used to demonstrate responsible sourcing.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
14-Mar-2024 - Wording clarified and expanded. Relevant prerequisites and requirements clarified. Scheme applicability updated.
Green-roofs - KBCN0263
When assessing green roofs, only the structural elements of the roof construction need to be considered i.e. the waterproof layer and above can be excluded. Where Green Guide is being used to assess the issue, it is likely that the online Green Guide Calculator will need to be used to provide a rating for the roof construction.
HQM - For the purpose of HQM, green roofs fall under 3.3 Specialist roof systems therefore should be included in the IMPACT model.
Homeowner’s report - KBCN1287
A homeowner's report should be undertaken for the occupants as the maintenance and operational costs will eventually be passed onto them. Therefore when putting together the report it should be assumed they are going to purchase the home.
The homeowner's report should be made available to anyone wanting to rent the home before they make a decision on whether to rent the home.
Homeowner’s life cycle cost report - KBCN1286
The life cycle cost analysis and lifecycle assessment can be undertaken per house type. A house type includes homes that are identical in specification, design and location (end/ mid-terrace, ground or mid/ top floor). Any home that does not meet this definition for house type will need to be modelled separately.
HQM Life Cycle Assessment – Methodology update - KBCN1743
From 6 July 2025, all HQM assessments (beta, ONE & V6) have the option to apply the new BREEAM UK New Construction: Residential (UKNCR) V6.1, Issue 6.2 LCA methodology.
UKNCR V6.1 updated issue ‘6.2 Environmental Impact of Materials’ by:
- Requiring LCA to be completed at building level
- Recognising and encouraging the completion of LCAs at early design, technical design and post-construction stages
- Providing scoring against embodied carbon benchmarks
- Rewarding projects that submit embodied carbon data to a public database
Please refer to issue 6.2 in the
UKNCR V6.1 technical manual for full details of the updated methodology.
Please refer to the
HQM Life Cycle Assessment – methodology update for further details on how to apply the UKNCR Issue 6.2 LCA methodology, and how this applies to each of the HQM scheme versions.
Please be aware that applying the UKNCR issue 6.2 LCA methodology will not change your HQM registration or certificate.
Insulation – Responsible sourcing - KBCN0907
Insulation is within the scope of the responsible sourcing of construction products.
30-Oct-2025 - Applicable to HQM One, HQM V6 and UKNCR V6.1
Product procurement policy after RIBA stage 2 - KBCN0994
Where a product procurement policy is put together at a later stage than RIBA stage 2, ‘02 Product procurement policy and product environmental information’ credits may still be achievable. If it can be confirmed by the person responsible for the policy that the policy will not restrict procurement of responsible sourced construction products due to its late production and implementation, then the credits can still be awarded (provided all other compliance requirements are met).
30-Oct-2025 - Applicable to HQM One, HQM V6 and UKNCR V6.1
Raised access floors – Responsible sourcing - KBCN00018
For the purposes of responsible sourcing, raised access floors should be considered as part of the floor structure.
30-Oct-2025 - Applicable to HQM Beta, HQM One, HQM V6 and UKNCR V6.1
Responsible Sourcing – Scope when a BREEAM assessment covers only part of the new building - KBCN1217
To give reliable results, the assessment of responsible sourcing must capture the interactions that occur across an entire design (the system). A design decision in one part of the design will, in many cases, cause knock-on effects to other parts of the design. If only part of a building being designed is included in the assessment the designer may choose a design option that optimises responsible sourcing performance for the limited part analysed, but will be unaware of potential detrimental effects to the overall responsible sourcing performance of the building.
In addition, if a responsible sourcing assessment only includes the construction products that form the BREEAM assessment area, inconsistencies arise with regards to construction products that serve all areas of the building in common. For example, an assessment on a central floor that excludes the roof, compared with an assessment on the (otherwise identical) top floor that does include the roof. This approach would be unfair.
Therefore, notwithstanding the exception below for internal finishes, the responsible sourcing scope must include the whole building design (as defined in Mat 03, 'Scope of assessment') even if the area covered by BREEAM assessment is only part of the design.
The exception to this is any construction products classified as '3. Internal finishes'. Internal finishes are specific to each part of the building with little or no functional relationship with other parts. Therefore, the scope of the assessment of internal finishes shall be limited to the assessed area only.
08 October 2025-made applicable to HQM and UK NCR
Responsible sourcing certification – validity - KBCN1693
Where it can be demonstrated that the responsible sourcing certificates were valid either at the time of specification, or at the time of purchase, they may contribute to the awarding of the credits.
BREEAM is primarily trying to encourage designers to take responsible sourcing into consideration when specifying or selecting products and as such it is not necessary for certification to be valid at the time of design or post-construction stage submissions.
30-Oct-2025 - Applicable to HQM V6 and UKNCR V6.1
SQCC reluctant to produce the reports in case their projections are inaccurate - KBCN1389
An LCC appraisal demonstrates that the homebuilder has taken care to identify the approximate replacement, operation, and maintenance costs of the asset. The forecasts are considered indicative and the information produced should not be solely used for decision making. Any assumptions, contingencies (in line with the methodology set in BS – ISO 15686-5:2008) should be declared in the report.