Applicability – no occupied spaces

Principle

Where:

  • The scope of assessment covers no occupied spaces and,
  • There is no valid way to filter credits from that issue,

Credits specifically related to occupied space are not awarded.

Outcome

The tables below show how this principle applies to affected issues.

  • Y means all credits are available (unless the comments state otherwise).
    Standard filtering rules still apply, so some credits can be filtered out where allowed in the criteria.
  • N means all credits in the issue cannot be awarded.
    These credits are not filtered out.
Issue Credits available Scope
Part 1
Hea 01 Daylighting Y Only answer C is available.
Hea 02 Control of glare from sunlight N
Hea 03 Internal and external lighting levels N
Hea 04 Lighting control N
Hea 05 Minimising flicker from lighting systems Y
Hea 06 View out N
Hea 07 User comfort control N
Hea 08 Y
Hea 09 N
Hea 10-13 Y
Part 2
Hea 14 Thermal comfort N
Hea 15 Smoking policy Y
Hea 16 Indoor air quality management Y
Hea 17 Acoustic conditions N
Hea 18 Legionella risk management Y
Hea 19 Drinking water management Y
16-Jul-2026 - Hea 09 corrected.
16-Dec-2022 - KBCN title and scope updated for better visibility. Error in Hea 03 amended. Applicability of KBCN applied only to affected issues (N, or modified answer options) with to minimise header space in the UI. Original content on Resources moved to new KBCN.
27-Nov-2025 - KBCN applicability updated to include all Hea credit issues.